Modular Safety Relays (200 Series)

Catalogs > Safety Products Catalog > Logic > Safety Relays > Modular Safety Relays (200 Series) > MSR220P

MSR220P

Introduction Specifications Product Selection Accessories Approximate Dimensions Block Diagram Typical Wiring Diagrams
Specifications

Safety Ratings
Standards EN 954-1, ISO 13849-1, IEC/EN 60204-1, IEC 60947-4-1, IEC 60947-5-1, ANSI 11.19, AS4024.1
Safety Classification Cat. 4 per EN 954-1 (ISO 13849-1), SIL CL3 per EN IEC 62061, PLe per ISO 13849-1
Functional Safety Data ¬ 
Note: For up-to-date information, visit http://www.ab.com/safety/
PFHD: < 3.7 x 10-10
MTTFd: > 825 years
Suitable for performance levels Ple (according to ISO 13849-1:2006) and for use in SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics
Certifications CE Marked for all applicable directives, cULus, c-Tick, and BG
Power Supply
Input Power Entry 24V DC from the base unit
Power Consumption 2 W
Inputs
Safety Inputs 1 N.C. or 2 N.C. or 3 N.C. or 1 N.C. + 1 N.O. or SM
Input Simultaneity Infinite
Input Resistance, Max. 900 W
Reset See base unit
Power On Delay/
Recovery Time
See base unit
Response Time See base unit
Environmental and Physical Characteristics
Enclosure Type Rating/
Terminal Protection
IP40 (NEMA 1)/
IP20
Operating Temperature [C (F)] -5…+55 ° (23…131 °)
Vibration 10…55 Hz, 0.35 mm
Shock 10 g, 16 ms, 100 shocks
Mounting 17.5 mm housing, 35 mm DIN Rail
Weight [g (lb)] 90 (0.20)
Conductor Size, Max. 0.2…4 mm2 (24…12 AWG)
 
¬ Usable for ISO 13849-1:2006 and IEC 62061. Data is based on the following assumptions:
- Mission time/Proof test interval of 20 years
- Functional test at least once within six-month period