MSR238DP

Click to enlarge - 440R-H23196_Product


Description

The MSR238 is an time-delayed output expansion module for the modular Minotaur MSR200 family of monitoring safety relays. It can be connected to either the MSR210 or MSR211 base unit or to the MSR230 output module to provide time-delayed outputs.

Up to two output modules can be connected to one base unit by simply removing the terminator, included with each base unit, and connecting the ribbon cables of the neighboring module. The connecting ribbon cable provides power to the MSR238 as well as a check on its status. The terminators must be inserted into the final output module.

The MSR238 has two safety rated outputs that work in parallel with the safety outputs of the base unit. When the output of the base unit is de-activated, the outputs of the MSR238 are de-activated after the time delay expires. The time delay is set by connecting jumpers to the wiring terminals.

The outputs are two normally open safety rated outputs. The safety outputs have independent and redundant internal contacts to help support the safety function. The delayed normally closed output is an auxiliary signal that must only be used to indicate the status of the MSR238.


Features


LED Indicators

Green CH1 Output Active
Green CH2 Output Active
  

Specifications

Safety Ratings
Standards EN 954-1, ISO 13849-1, IEC/EN 60204-1, IEC 60947-4-1, IEC 60947-5-1, ANSI 11.19, AS4024.1
Safety Classification Cat. 3 per EN 954-1 (ISO 13849-1), SIL CL2 per EN IEC 62061, PLe per ISO 13849-1
Functional Safety Data ⋆ 
Note: For up-to-date information, visit http://www.ab.com/safety/
PFHD: < 7.7 x 10-9
MTTFd: > 373 years
Suitable for performance levels Ple (according to ISO 13849-1:2006) and for use in SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics
Certifications CE Marked for all applicable directives, cULus, c-Tick, and TÜV
Power Supply
Input Power Entry 24V DC from the base unit
Power Consumption 2.5 W
Outputs
Safety Contacts 2 N.O.
Auxiliary Contacts 1 N.C.
Thermal CurrentIlth 1 x 6 A or 2 x 4 A (nonswitching)
Rated Impulse withstand Voltage 2500V
Switching Current @ Voltage, Min. 10 mA @ 10V DC
Fuses, Output Recommended External 6 A slow blow or 10 A fast acting
Electrical Life (Operations) 220V AC/4 A/880VA cosf = 0.35…0.1 M
220V AC/1.7 A375VA cosf = 0.6…0.5 M
30V DC/2 A/60 W = 1 M
10V DC/0.01 A/0.1 W = 2 M
Mechanical Life 10,000,000 cycles
Utilization Category
Resistive: AC-1 6 A @ 250V AC
Resistive: DC-1 6 A @ 24V DC
Inductive: AC-15 5 A @ 250V AC
Inductive: DC-13 3 A @ 24V DC
UL: 1 x B300, P300 or 2 x C300, 1 x 6 A or 2 x 4 A Resistive
Environmental and Physical Characteristics
Enclosure Type Rating/
Terminal Protection
IP40 (NEMA 1)/
IP20
Operating Temperature [C (F)] -5…+55 ° (23…131 °)
Vibration 10…55 Hz, 0.35 mm
Shock 10 g, 16 ms, 100 shocks
Mounting 35 mm DIN Rail
Weight [g (lb)] 215 (0.47)
Conductor Size, Max. 0.2…2.5 mm2 (24…14 AWG)
 
⋆ Usable for ISO 13849-1:2006 and IEC 62061. Data is based on the following assumptions:
- Mission time/Proof test interval of 20 years
- Functional test at least once within six-month period

Product Selection

Delayed Safety Outputs Delayed Auxiliary Outputs Terminals Reset Type Power Supply Cat. No.
2 N.O. 1 N.C. Removable 24V DC from the base unit 440R-H23196
  

Accessories

Description Cat. No.
Bag of 4, 4-Pin Screw Terminal Blocks 440R-A23209
Bag of 4, 4-Pin Spring Clamp Terminal Blocks 440R-A23228
  

Approximate Dimensions

Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.

Click to enlarge - 440R-H23196_Dim

Block Diagram

Click to enlarge - 440R-H23196_Block Diagram

Typical Wiring Diagrams

Click to enlarge - 440R-H23196_Wiring 01

Application Details (Typical)

Apply jumpers (links) on the terminals identified to achieve the desired off delay.

Delay (s) Jumper Jumper Delay (s) Jumper Jumper Delay (s) Jumper Jumper
0 None None 8 Y3-Y6 Y3-Y7 50 Y3-Y6 Y3-Y8
0.5 Y3-Y5 None 9 Y4-Y5 Y3-Y7 60 Y4-Y5 Y3-Y8
1 Y4-Y6 None 10 None Y4-Y8 80 None Y4-Y7
1.5 Y3-Y6 None 12 Y3-Y5 Y4-Y8 100 Y3-Y5 Y4-Y7
2 Y4-Y5 None 15 Y4-Y6 Y4-Y8 120 Y4-Y6 Y4-Y7
3 Y3-Y5 Y4-Y6 18 Y3-Y6 Y4-Y8 160 Y3-Y6 Y4-Y7
4 Y3-Y6 Y4-Y5 21 Y4-Y5 Y4-Y8 200 Y4-Y5 Y4-Y7
5 None Y3-Y7 26 None Y3-Y8 250 Y3-Y5, Y4-Y6 Y3-Y7
6 Y3-Y5 Y3-Y7 30 Y3-Y5 Y3-Y8 300 Y3-Y5, Y4-Y5 Y3-Y7
7 Y4-Y6 Y3-Y7 40 Y4-Y6 Y3-Y8