1732DS ArmorBlock Guard I/O
ArmorBlock® Guard I/O™
|
Description
ArmorBlock® Guard I/O™ provides all the advantages of traditional distributed I/O for safety systems, but has an IP64, IP65, or IP67 package (as marked on the product label) that can be mounted directly on your machine. On-machine safety I/O reduces wiring time and startup costs for safety controller applications by eliminating electrical boxes and simplifying cable installation. The ArmorBlock family provides industrially hardened I/O blocks that you can mount directly on equipment near sensors or actuators. Wiring the I/O to the sensors and actuators is easy using pre-wired quick disconnect cables.
You can use Guard I/O with any safety controller that communicates on DeviceNet using CIP Safety for the control and monitoring of safety circuits. Guard I/O detects circuit failures at each I/O point while providing detailed diagnostics directly to the controller. With CIP Safety, you can easily integrate safety and standard control systems by using safety and standard messages on the same wire.
The 1732DS ArmorBlock Guard I/O family consists of 24V DC digital I/O modules that communicate on DeviceNet networks. The I/O connectors are sealed M12 micro style while the network and auxiliary power connectors are sealed mini style. Plus, the ArmorBlock Guard I/O uses the same input and output M12 pin configuration as standard ArmorBlock and MaXum.
Benefits
- IP64, IP65, or IP67 rated for direct mounting on machine without an enclosure
(rating is marked on the product label)
- Compact footprint
- Quick disconnect dual-channel M12 I/O connectors allow a single cable connected between ArmorBlock Guard I/O and a dual-channel safety device (See the following table of Allen-Bradley Guardmaster safety devices)
- TÜV certified as a system with GuardLogix and SmartGuard 600 controllers
- Supports both standard and safety control
- Supports single and dual-channel devices on inputs and outputs
- I/O point-level and other detailed fault diagnostics are available to the PLC or HMI with self-testing inputs and outputs
- EDS (RSNetWorx for DeviceNet) or RSLogix 5000 profile configuration
- Certified by TÜV and UL for Functional Safety up to SIL 3 according to IEC 61508, and PLe/Category 4, according to ISO 13849-1
- Additional standard solid-state outputs can be configured as pulse test sources, outputs for standard PLC control, 24V DC sources, or muting lamp control and monitoring
Specifications
| Cat. No. | 1732DS-IB8 | 1732DS-IB8XOBV4 |
| Description | 24V DC Input Module for DeviceNet Networks | 24V DC Input/Output Module on DeviceNet Networks |
| Current Consumption | — | |
| I/O Operating Voltage Range | 19.2V…28.8 V DC (24V DC, -20…+20%) | |
| Digital Inputs | ||
| Number of Inputs | 8 safety single-channel or 4 safety dual-channel | |
| Input Type | current sinking | |
| Voltage, On-State Input, Min. | 11V DC | |
| Voltage, Off-State Input, Max. | 5V DC | |
| Current, On-State Input, Min. | 3.3 mA | |
| Digital Outputs | ||
| Number of Outputs | — | 4 safety solid-state |
| Output Type | — | dual channel, current sourcing/current sinking pair |
| Output Current Rating | — | 2.0 A max per point 8 A total module at40 °C (104 °F) 6 A total module at 60 °C (140 °F) |
| Short Circuit Protection | — | Yes |
| Standard Pulse Test Outputs | ||
| Number of Pulse Test Sources | 8 | |
| Pulse Test Output Current | 0.7 A per point | |
| Short Circuit Protection | Yes | |
| General | ||
| Operating Temperature | -20°…+60°C (-4°C…+140°F) | |
| Relative Humidity | 10…95% non-condensing | |
| Vibration | 0.76 mm @ 10…500 Hz | |
| Operating Shock | 30 g | |
| Enclosure Protection | IP64, IP65, or IP67 as marked on the product label | |
| Dimensions (HxWxD), Metric | 179 x 70 x 68.7 mm⋆ | |
| Dimensions (HxWxD), Imperial | 7.05 x 2.76 x 2.71 in⋆ | |
| Weight, Metric | 600 g | |
| Weight, Imperial | 1.2 lb | |
| Certifications | UL, CE, C-Tick, CSA, UL NRGF, ODVA Conformance, certified by TÜV for Functional Safety up to SIL 3 and PLe/Cat. 4 | |
| ⋆ Includes terminal block. When product is marked. See the Product Certification link at http://www.ab.com/certification for Declarations of Conformity, Certificates, and other certification details. All specifications are subject to change. Refer to product installations instructions. |
||
ArmorBlock Guard I/O Connections
| Safety Products That Connect Directly to ArmorBlock Guard I/O With a Single 5-pin Micro (M12) Patchcord⋆ | ||
| Product Family | Actuator Type | Cat. No. (with M12) |
| Elf | Flat | 440K-E2NNFPS |
| Semi-flexible | 440K-E2NNAPS | |
| Cadet | Flat | 440K-C2NNFPS |
| Semi-flexible | 440K-C2NNAPS | |
| Trojan T15 | Standard | 440K-V2NNSPS |
| Fully-flexible | 440K-V2NNBPS | |
| Trojan T15-GD2 | GD2 Standard | 440K-V2NNGPS |
| Trojan T5 | Standard | 440K-T2NBSPS |
| Fully-flexible | 440K-T2NBBPS | |
| Trojan T5-GD2 | GD2 Standard | 440K-T2NBGPS |
| MT-GD2, Case Color Red with Snap-acting Contacts | None | 440K-M2NBNDS |
| None | 440K-M2NANDS | |
| MT-GD2, Case Color Yellow, Snap-acting Contacts | None | 440K-M2NANYS |
| Sprite | Solid - 50xÆ10 mm | 440H-S2NNPPS |
| Pre-bored - 30xÆ16 mm | 440H-S2NNHPS | |
| Ensign | Solid - 50xÆ10 mm | 440H-E2NNPPS |
| Pre-bored - 30xÆ16 mm | 440H-E2NNHPS | |
| Lifeline3 | N/A | 440E-D2NNNYS |
| Lifeline4 | N/A | 440E-L2NNNYS |
| Emergency Stop | N/A | 800F-1YMQ53V |
| Safety Mats | N/A | 440F-MxxxHxNN |
| ⋆ Only the 2 N.C. safety contacts of the safety switches are connected to the 5-pin micro (M12) connector. | ||
1732DS ArmorBlock Guard I/O Micro Connector Pin Assignments
1732DS ArmorBlock Guard I/O Mini Connector Pin Assignments
| ArmorBlock Guard I/O DeviceNet Configuration | |||
| Pin | Signal | Male | Female |
| 1 | Drain |
|
|
| 2 | V+ (Red) | ||
| 3 | V- (Black) | ||
| 4 | CAN_H (White) | ||
| 5 | CAN_L (Blue) | ||
| ArmorBlock Guard I/O Power Configuration | ||
| Pin | Signal | Male |
| 1 | Output +24V DC Power (Red) |
|
| 2 | Input +24V DC Power (Green) | |
| 3 | Input Power Common (White) | |
| 4 | Output Power Common (Black) | |
ArmorBlock Guard I/O Recommended Compatible Cables and Connectors
Single Channel Wiring (879D-F4ACD5M and 1485P-PID5-RR4)
|