Catalogs > Safety Products Catalog > Logic > Programmable Safety Solutions > GuardPLC Safety Control Systems > GuardPLC Safety Control Systems Overview
GuardPLC Safety Control Systems Overview
GuardPLC™ Safety Control Systems
|
System Overview
|
The GuardPLC system is a state-of-the-art safety system offering fast safety PLCs, optimum controller throughput, and a reliable safety network.
The GuardPLC system meets the worldwide standard for programmable controls, complying with many of the latest global safety standards and the worldwide standard for functional safety in programmable electronic systems. The GuardPLC system can be used without restriction in applications up to Safety Integrity Level 3 (SIL 3) according to IEC 61508 and PLe/Category 4, according to ISO 13849-1.
The GuardPLC system consists of four main components:
- Packaged controller and associated integrated I/O
- Safety Communication via GuardPLC Ethernet networks
- Distributed I/O modules for GuardPLC Ethernet networks
- Programming and configuration software
Benefits
Benefits resulting from the use of safety PLCs and safety networks include:
- Greater integration and flexibility of machine controls.
- Capability for better and easier diagnostics when intelligence is provided to the standard control level
- Faster and easier maintenance
- Reduction in the cost of installation, commissioning, and reconfiguring
- Reduction in design and hardware costs, compared to using safety relays alone for logic
- Potential for throughput performance improvement in more complex systems
GuardPLC Safety Control Systems
|
|
|
|
| GuardPLC 1600 Controller | GuardPLC 1800 Controller | Distributed Safety I/O for GuardPLC Ethernet | |
| Description | A cost-effective safety PLC offering a built-in 4-port Ethernet switch, digital I/O, and flexible communication options for connecting devices. | Analog inputs and high-speed counters allow the GuardPLC 1800 to sense temperature, pressure, speed, and motion. | Distributed safety I/O blocks provide exceptional flexibility in configuring the right mix of I/O in the right place. |
| Memory | 250kB user program 250kB application data |
250kB user program 250kB application data |
— |
| Digital I/O | 20 inputs 8 outputs |
24 inputs 8 outputs |
16 inputs only 16 outputs only 8 inputs and 8 outputs 16 inputs and 8 outputs 20 inputs and 8 outputs |
| Other I/O | — | 8 analog inputs 2 high-speed counters |
8 analog inputs 8 relay outputs |
| Embedded Ethernet | 4-port switch | 4-port switch | 2-port switch |
| Other Communications | EtherNet/IP GuardPLC Ethernet Modbus RTU Slave or PROFIBUS DP Slave ASCII (RS-485) |
EtherNet/IP GuardPLC Ethernet Modbus RTU Slave or PROFIBUS DP Slave ASCII (RS-485) |
GuardPLC Ethernet |
| Programming Software | All GuardPLC controllers are programmed with RSLogix Guard PLUS! Programming Software. | ||