Catalogs > Safety Products Catalog > Power > Safety Isolation System
Safety Isolation System
| Introduction | Specifications | Sequence of Operation | Communication | Product Selection | Introduction |
| Optional Expansion Module | Remote Lockout Station | Verification Module | Multiplexer/Permissive Module | System Selection Process |
|
| Verification Module |
Verification Module
The optional Verification Module (VM) is connected between the solenoid locking safety switch, similar to a Guardmaster Atlas™ 5 and the Remote Lockout Station (RLS) input on an ElectroGuard system. When the VM receives the system isolated signal from the ElectroGuard, the VM provides the signal to the solenoid on the Atlas 5, unlocking the Atlas 5 and allowing access to the machine.
Once the Atlas 5 is unlocked, the VM provides a redundant signal to the ElectroGuard emulating a RLS that has been switched to the OFF position. The emulated signal is then switched to the on state, to indicate the gate has been closed. If all of the RLSs connected to the ElectroGuard are switched to the ON position and the safety gate is closed, the ElectroGuard will attempt to lock the gate and restore energy the machine. If the verification module has not verified the gate is locked, the energy is removed from the machine and the locking process is repeated.
Specifications
Dry Contact (B300 6A/125V AC or P300 3A/24V DC) provided to control solenoid voltage.
Bulletin 2030 Verification Module
| 2030 | — | VM | C | |
| a | b |
| a | |
| Product Description | |
| Code | Description |
| VM | Verification module |
| b | |
| Enclosure Type | |
| Code | Description |
| C | Type 4X watertight stainless steel |
| J | Type 12 dusttight/IP54 |