Catalogs > Safety Products Catalog > Power > Contactors and Control Relays > Bulletin 700S-P and 700S-PK Heavy-Duty Safety Control Relay
Bulletin 700S-P and 700S-PK Heavy-Duty Safety Control Relay
Specifications| Type | 700S-P | 700S-PK | ||||||||||||
| Electrical | ||||||||||||||
| Contact Rating Continuous | 10 A @ 600V AC 5 A @ 600V DC |
20 A @ 600V AC 10 A @ 600V DC |
||||||||||||
| Ratings Make/Break |
AC | NEMA A600 | NEMA A600 | |||||||||||
| DC | NEMA P600 | NEMA P600 | ||||||||||||
| Minimum Contact Switching Ratings | 10V, 50 mA | 3 Hp @ 240V AC - N.O. 2 Hp @ 240V AC - N.O./N.C. 1 HP @ 120V AC - N.O./N.C. 20 A resistive heating to 600V AC 20 A Tungsten lighting load to 480V AC |
||||||||||||
| DC Switching | Contacts in Series |
Volts DC | Volts DC | |||||||||||
| 24V | 64V | 125V | 250V | 500V | 600V | 24V | 64V | 125V | 250V | 500V | 600V | |||
| 1 | 5 A | 2.2 A | 1.1 A | 0.55 A | 0.24 A | 0.2 A | 10 A | 5 A | 2.2 A | 0.55 A | 0.24 A | 0.2 A | ||
| 2 | 10 A | 10 A | 5 A | 2 A | 0.7 A | 0.5 A | 20 A | 10 A | 5 A | 2 A | 0.7 A | 0.5 A | ||
| 3 | — | — | 7 A | 3 A | 1.5 A | 1.0 A | — | 15 A | 7 A | 3 A | 1.5 A | 1.0 A | ||
| 4 | — | — | 10 A | 5 A | 2.5 A | 1.5 A | — | 20 A | 10 A | 5 A | 2.5 A | 1.5 A | ||
| Coil Voltage Range⋆ | AC | 85…110% | 85…110% | |||||||||||
| DC | 80…110% | 80…110% | ||||||||||||
| Battery Charging |
85…115% | 85…115% | ||||||||||||
| Coil Consumption | 50 Hz | 60 Hz | 50 Hz | 60 Hz | ||||||||||
| AC | Inrush | 132 VA | 138 VA | 132 VA | 138 VA | |||||||||
| Sealed | 19.3 VA | 19 VA | 19.3 VA | 19 VA | ||||||||||
| DC | Inrush | 12.7 W | 12.7 W | |||||||||||
| Sealed | 12.7 W | 12.7 W | ||||||||||||
| Additional Contact Rating for AC Single-Phase Loads | — | 3 HP @ 240V AC - N.O. 2 HP @ 240V AC - N.O./N.C. 1 HP @ 130V AC - N.O./N.C. 20 A Resistive Heating to 600V AC 20 A Tungsten Lighting Load to 480V AC Cartridge Cat. No. Bulletin 700S-CMS |
||||||||||||
| Mechanical | ||||||||||||||
| Mechanically Linked Contacts | All contacts are mechanically linked per IEC 947-5-1 annex L for 2 to 12 poles | All contacts are mechanically linked per IEC 947-5-1 annex L for 2 to 12 poles | ||||||||||||
| Operating Time | Pickup | AC 10…20 ms DC 30…50 ms |
AC 10…20 ms DC 30…50 ms |
|||||||||||
| Dropout | AC 10…20 ms DC 20…33 ms |
AC 10…20 ms DC 20…33 ms |
||||||||||||
| Mechanical Life | 10 million operations | |||||||||||||
| Construction | ||||||||||||||
| Contact Arrangement | 2 to 12 Poles, Double Break Contacts N.O. or N.C. (8 N.C. Maximum) |
2 to 12 Poles, Convertible to N.O. or N.C. (8 N.C. Maximum) | ||||||||||||
| Contact Material/Design | Silver Nickel/Bifurcated | Silver Cadmium Oxide | ||||||||||||
| Mounting | Panel mount or mount on 700-MP Relay or DIN Rail Horizontal Mounting Recommended |
Panel mount or mount on 700-MP Relay or DIN Rail Horizontal Mounting Recommended |
||||||||||||
| Environmental | ||||||||||||||
| Temperature | Operating§ | 20…+65 °C (4…+149 °F) | 20…+65 °C (4…+149 °F) | |||||||||||
| Storage | 40…+65 °C (40…+149 °F) | 40…+65 °C (40…+149 °F) | ||||||||||||
| Wire Terminations | ||||||||||||||
| Wire size per UL/CSA | #18 AWG…(2) #12 AWG | #18 AWG…(2) #12 AWG | ||||||||||||
| Tightening Torque | 8…12 lbin (0.9…1.4 Nm) | 8…12 lbin (0.9…1.4 Nm) | ||||||||||||
| ⋆ Coil voltage required for proper operation (percent of rated coil voltage). | ||||||||||||||