Bulletin 100S-C/104S-C Safety Contactors

Click to enlarge - 100S-C_104S-C-77-1 Click to enlarge - 100S-C_104S-C-77-2


Bulletin 100S-C/104S-C safety contactors provide mechanically linked positively guided contacts, required in feedback circuits of modern safety applications. The mechanically linked N.C. auxiliary contacts will not change state when a power pole welds. In addition, the gold-plated bifurcated auxiliary contacts are ideally suited for low-energy applications or feedback control circuits with multiple series-connected N.C. auxiliary contacts.

Your order must include: cat. no. of the contactor specified with coil voltage code and, if required, cat. no. of any accessories and/or replacement coils.

Standards Compliance and Certifications

Standards Compliance

EN50205
CSA C22.2 No. 14
UL 508
EN/IEC 60947-4
IEC 60947-4-1 Annex H — Mirror Contacts
IEC 60947-5-1 Annex L — Mechanically Linked Contacts


Certifications

SUVA Third-Party Certified
CE Marked
cULus Listed (File No. E3125;
Guide NLDX, NLDX7)


Product Selection

3-Pole AC- and DC-Operated Contactors

Ie [A] Ratings for Switching AC Motors — AC-2, AC-3, AC-4 Aux. Contacts Cat. No.⋆ ‡ 
3-Phase kW (50 Hz) Hp (60 Hz) Click to enlarge - 100M-66a-3 Click to enlarge - 100M-66-4a
AC-3 AC-1 230V 400V/
415V
500V 690V 1-Phase 3-Phase   Click to enlarge - 100S-C_104S-C-77-5
115V 230V 200V 230V 460V 575V N.O. N.C.
9 32 3 4 4 4 1/2 1-1/2 2 2 5 7-1/2 0 5 100S-C09Ä05BC
1 4 100S-C09Ä14BC
12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 10 0 5 100S-C12Ä05BC
1 4 100S-C12Ä14BC
16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 15 0 5 100S-C16Ä05BC
1 4 100S-C16Ä14BC
23 32 7.5 11 13 10 2 3 5 7-1/2 15 15 0 5 100S-C23Ä05BC
1 4 100S-C23Ä14BC
30 65 10 15 15 15 2 5 7-1/2 10 20 25 0 4 100S-C30Ä04BC
1 4 100S-C30Ä14BC
37 65 11 18.5/20 20 18.5 3 5 10 10 25 30 0 4 100S-C37Ä04BC
1 4 100S-C37Ä14BC
43 85 13 22 25 22 3 7-1/2 10 15 30 30 0 4 100S-C43Ä04BC
1 4 100S-C43Ä14BC
60 100 18.5 32 37 32 5 10 15 20 40 50 0 4 §  100S-C60Ä04BC
1 4 §  100S-C60Ä14BC
72 100 22 40 45 40 5 15 20 25 50 60 0 4 §  100S-C72Ä04BC
1 4 §  100S-C72Ä14BC
85 100 25 45 55 45 7-1/2 15 25 30 60 60 0 4 §  100S-C85Ä04BC
1 4 §  100S-C85Ä14BC
97 130 30 55 55 55 10 15 30 30 75 75 0 4 §  100S-C97Ä04BC
1 4 §  100S-C97Ä14BC
  
⋆ For other contact configurations and full product details, please contact your local Rockwell Automation sales office or Allen-Bradley distributor.
‡ If standard cross-stamped front-mount auxiliary contacts are required, remove the letter "B" before the letter "C" in the cat. no. Example: Cat. No. 100S-C09Ä05BC becomes Cat. No. 100S-C09Ä05C.
§ Bifurcated front-mount auxiliary contacts on Cat. Nos. 100S-C60…C97 conform to mirror contact performance only.
Ä Coil Voltage Code, see Ä Coil Voltage Code and Terminal Position

Click to enlarge - 100C_104C-68-1
Cat. No.
100S-C09Ä05C
Line Side


Click to enlarge - 100C_104C-68-2
Cat. No.
100S-C09UÄ05C
Load Side


4-Pole AC- and DC-Operated Contactors

Ie [A] Ratings for Switching AC Motors Contact Configuration Cat. No.⋆ §  Price
AC-2, AC-3, AC-4 Hp (60 Hz)
3-Phase kW (50 Hz)‡  Main Pole Auxillary Contacts
AC-3 AC-1 230V 400V/
415V
500V 690V 1-Phase 3-Phase ‡  Click to enlarge - 100M-66-3a Click to enlarge - 100M-66-4a Click to enlarge - 100M-66-3a Click to enlarge - 100M-66-4a AC
Coil
DC
Coil
      Click to enlarge - 100S-C_104S-C-77-5
115V 230V 200V 230V 460V 575V N.O. N.C. N.O. N.C.
9 32 3 4 4 4 1/2 1-1/2 2 2 5 7-1/2 4 0 0 4 100S-C09Ä404BC    
3 1 0 4 100S-C09Ä304BC    
12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 10 4 0 0 4 100S-C12Ä404BC    
3 1 0 4 100S-C12Ä304BC    
16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 15 4 0 0 4 100S-C16Ä404BC    
3 1 0 4 100S-C16Ä304BC    
23 32 7.5 11 13 10 2 3 5 7-1/2 15 15 4 0 0 4 100S-C23Ä404BC    
3 1 0 4 100S-C23Ä304BC    
  
⋆ For other contact configurations, please contact your local Rockwell Automation sales office or Allen-Bradley distributor.
‡ Three-phase ratings only apply to contactors with at least three N.O. power poles.
Ä Coil Voltage Code, see Ä Coil Voltage Code and Terminal Position
§ If standard cross-stamped front-mount auxiliary contacts are required, remove the letter "B" before the letter "C" in the cat. no. Example: Cat. No. 100S-C09Ä404BC becomes Cat. No. 100S-C09Ä404C.

Reversing AC- and DC-Operated Contactors


Click to enlarge - 100S-C_104S-C-77-2


Ie [A] Ratings for Switching AC Motors Aux. Contacts
Installed per Contactor
Cat. No.⋆ ‡ 
AC-2, AC-3, AC-4 Click to enlarge - 100M-66-3a Click to enlarge - 100M-66-4a
3-Phase kW (50 Hz) Hp (60 Hz)
AC-3 AC-1 230V 400V/
415V
500V 690V 1-Phase 3-Phase   Click to enlarge - 100S-C_104S-C-77-5
115V 230V 200V 230V 460V 575V N.O. N.C. § 
9 32 3 4 4 4 1/2 1-1/2 2 2 5 7-1/2 0 6 104S-C09Ä012BC
1 5 104S-C09Ä210BC
12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 10 0 6 104S-C12Ä012BC
1 5 104S-C12Ä210BC
16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 15 0 6 104S-C16Ä012BC
1 5 104S-C16Ä210BC
23 32 7.5 11 13 10 2 3 5 7-1/2 15 15 0 6 104S-C23Ä012BC
1 5 104S-C23Ä210BC
30 65 10 15 15 15 2 5 7-1/2 10 20 25 0 5 104S-C30Ä010BC
1 5 104S-C30Ä210BC
37 65 11 18.5/20 20 18.5 3 5 10 10 25 30 0 5 104S-C37Ä010BC
1 5 104S-C37Ä210BC
43 85 13 22 25 22 3 7-1/2 10 15 30 30 0 5 104S-C43Ä010BC
1 5 104S-C43Ä210BC
60 100 18.5 32 37 32 5 10 15 20 40 50 0 5 ♣  104S-C60Ä010BC
1 5 ♣  104S-C60Ä210BC
72 100 22 40 45 40 5 15 20 25 50 60 0 5 ♣  104S-C72Ä010BC
1 5 ♣  104S-C72Ä210BC
85 100 25 45 55 45 7-1/2 15 25 30 60 60 0 5 ♣  104S-C85Ä010BC
1 5 ♣  104S-C85Ä210BC
97 130 30 55 55 55 10 15 30 30 75 75 0 5 ♣  104S-C97Ä010BC
1 5 ♣  104S-C97Ä210BC
  
⋆ For other contact configurations, please contact your local Rockwell Automation sales office or Allen-Bradley distributor.
‡ If standard cross-stamped front-mount auxiliary contacts are required, remove the letter "B" before the letter "C" in the cat. no. Example: Cat. No. 104S-C09Ä05BC becomes Cat. No. 104S-C09Ä05C.
§ One of the N.C. auxiliary contacts is supplied as part of the mechanical/electrical interlock.
♣ Bifurcated front-mount auxiliary contacts on Cat. Nos. 104S-C60…C97 conform to mirror contact performance only.
Ä Coil Voltage Code, see Ä Coil Voltage Code and Terminal Position

Ä Coil Voltage Code and Terminal Position

The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the Cat. No. Example: 120V, 60Hz: Cat. No. 100S-C09Ä05BC becomes Cat. No.100S-C09D05BC.

[V] 12 24 32 36 42 48 100 100-110 110 120 127 200 200-220 208 208-240 220-230
AC, 50 Hz R K V W X Y KP D P S KG L F
AC, 60 Hz Q J V X KP D KG H L
AC, 50/60 Hz KJ KY KP KD KG KL§  KL§ 
  
[V] 230 230-240 240 277 347 380 380-400 400 400-415 440 480 500 550 600  
AC, 50 Hz VA T N G B M C
AC, 60 Hz A T I E N B C
AC, 50/60 Hz KF KA KN KB
  
§ Not available in 100S/104S-C97 contactors

[V] 9 12 24 36 48 60 64 72 80 110 115 125 220 230 250
100S/104S-C09…C43 Standard DC ZR ZQ ZJ ZW ZY ZZ ZB ZG ZE ZD ZP ZS ZA ZF ZT
with Integrated Diode DJ
Electronic with Integrated Diode EJ
100S/104S-C60…C97 with Integrated Diode DR DQ DJ DW DY DZ DB DG DE DD DP DS DA DF DT
  

Coil Terminal Position


Bulletin 100S-C/104S-C Accessories

Control Modules (For 100S-C09…C97 contactors)

  Description Connection Diagrams For Use With Cat. No.
Click to enlarge - 100-C_104-C-87-1 Pneumatic Timing Modules
  • Pneumatic timing element contacts switch after the delay time. The contacts on the main control relay continue to operate without delay.
  • On-Delay  
    0.3…30 s Range
    Click to enlarge - 100-C_104-C-87-2 100-C or 700-CF with AC coils or DC electronic coils   
    100-FPTA30
    1.8…180 s Range 100-FPTA180
    Off-Delay  
    0.3…30 s Range
    Click to enlarge - 100-C_104-C-87-3 100-C all, 700-CF all   
    100-FPTB30
    1.8…180 s Range 100-FPTB180
    Click to enlarge - 100-ETA3 L_gs- Electronic Timing Modules — On-Delay
    Delay of the contactor or control relay solenoid.
    The contactor or control relay is energized at the end of the delay time.
    On-Delay  
    1…30 s Range
    Click to enlarge - 100-C_104-C-87-5 100-C or 700-CF with 24…48V DC coils   
    100-ETA3
    1…30 s Range 100-ETA30
    10…180 s Range 100-ETA180
      
    110…240V, 50/60 Hz
    110…250V DC
     
    On-Delay  
    0.1…3 s Range
    Click to enlarge - 100-C_104-C-87-6 100-C or 700-CF with 24…48V DC coils   
    100-ETAZJ3
    1…30 s Range 100-ETAZJ30
    10…180 s Range 100-ETAZJ180
      
    24…48V DC
     
    Click to enlarge - 100-ETB3 L_gs Electronic Timing Modules — Off-Delay
    Delay of the contactor or control relay solenoid.
    After interruption of the control signal, the contactor or control relay is deenergized at the end of the delay time.
    Off-Delay  
    0.3…3 s Range
    Click to enlarge - 100-C_104-C-87-8 100-C09…C37 or 700-CF with 24V 50/60 Hz coils   
    100-ETBKJ3
    1…30 s Range 100-ETBKJ30
    10…180 s Range 100-ETBKJ180
      
    24V, 50/60 Hz
     
    Off-Delay  
    0.3…3 s Range
    100-C or 700-CF with 110…240V 50/60 Hz coils   
    100-ETB3
    1…30 s Range 100-ETB30
    10…180 s Range 100-ETB180
      
    110…240V, 50/60 Hz
     
    Click to enlarge - 100-C_104-C-87-9 Electronic Timing Modules
  • Delay of the contactor solenoid. Contactor K 3 (Y) is de-energized (off) and K 2 (D) is energized (on) after the end of the set Y end time. (Switching delay at 50 ms.)

  • Continuous adjustment range

  • High repeat accuracy
  • Transition Time Y Contactor
    1…30 s Range
      

    110…240V, 50/60 Hz
    Click to enlarge - 100-C_104-C-87-10 100-C with 110…240V, 50/60 Hz coils 100-ETY30
    Click to enlarge - 100-C_104-C-87-11 Mechanical Interlocks
  • For interlocking of two contactors.

  • Common interlock for all Bul. 100-C contactor sizes

  • Interlocking of different sizes possible

  • Mechanical and electrical interlocking possible in one module by means of integrated auxiliary contacts

  • 9 mm dovetail connector included
  • Mechanical only,
    without auxiliary contacts
    Click to enlarge - 100-C_104-C-87-12 100-C (except 100-C40, -C90) 100-MCA00
    Mechanical/ electrical interlock with 2 N.C. auxiliary contacts Click to enlarge - 100-C_104-C-87-13 100-C (except 100-C40, -C90) 100-MCA02
    Click to enlarge - 100-C_104-C-87-15 Mechanical Latch
  • Following contactor latching, the contactor coil is immediately de-energized (off) by the N.C. auxiliary contact (65-66).

  • Electrical or manual release

  • 1 N.O. + 1 N.C. auxiliary contacts

  • Suitable for all Bul. 100-C contactor sizes, 9…97 A
  • Maximum command duration 0.03…10 s Click to enlarge - 100-C_104-C-87-14 100-C with AC or 24V DC electronic coils (except 100-C90) 100-FL11Ä
      
    Package Quantity = 1

    Ä Coil Voltage Code

    The cat. no. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: 120V, 60 Hz:
    Cat. No. 100-FL11Ä becomes Cat. No. 100-FL11D.


    [V]⋆  24V 48V 100V 110V 120V 230-240V 240V 277V 380-400V 400-415V 440V 480V
    AC, 50 Hz K Y KP D VA T N G B
    AC, 60 Hz J D A T N B
      
    ⋆ For special voltages, please contact your local Rockwell Automation sales office or Allen-Bradley distributor.

    Control Modules (For 100S-C09…C97 contactors), Continued

    Click to enlarge - 100-C_104-C-88-1 Description Voltage Range Connection Diagrams For Use With Cat. No.
    DC Interface (Electronic)
  • Interface between the DC control signal (PLC) and the AC operating mechanism of the contactor.

  • Requires no additional surge suppression on the relay coils
  • Input: 12V DC
    Output: 110…240V AC
    Click to enlarge - 100-C_104-C-88-2 100-C with AC coils 110…240V AC 100-JE12
    Input: 18…30V DC
    Output: 110…240V AC
    100-JE
    Input: 48V DC
    Output: 110…240V AC
    100-JE48
    Click to enlarge - 100-C_104-C-88-3 Surge Suppressors
  • For limitation of coil switching transients.

  • Plug-in, coil mounted.

  • Suitable for 100-C contactor sizes, 9…97 A.

  • RC, varistor, and diode versions.
  • RC Module
    AC operating mechanism
    24…48V AC, 50/60 Hz Click to enlarge - 100D-92-2 100-C with AC coils 100-FSC48
    110…280V AC, 50/60 Hz 100-FSC280
    380…480V AC, 50/60 Hz 100-FSC480
    Varistor Module
    AC/DC operating mechanism
    12…55V AC/ 12…77V DC Click to enlarge - 100-C_104-C-88-5 100-C with AC coils or 100-C09…-C43 with DC coils 100-FSV55
    56…136V AC/ 78…180V DC 100-C with AC coils or 100-C09…-C43 with DC coils 100-FSV136
    137…277V AC/ 181…350V DC 100-C with AC coils or 100-C09…-C43 with DC coils 100-FSV277
    278…575V AC 100-C with AC coils or 100-C09…-C43 with DC coils 100-FSV575
    Diode Module
    DC operating mechanism
    12…250V DC Click to enlarge - 100-C_104-C-88-6 100-C09…-C43 with DC coils 100-FSD250
      

    Assembly Components (For 100S-C09…C97 contactors)

      Description For Use With Pkg. Quantity⋆  Cat. No.
    Click to enlarge - 100-C_104-C-88-7 Dovetail Connectors
  • For use in contactor and starter assemblies.

  • Single Connector — 0 mm Spacing
  • 100-C 10 100-S0
    Cat. No. 100-S0 Dovetail Connectors
  • For use in contactor and starter assemblies.

  • Dual Connector — 9 mm Spacing
  • 100-S9
    Click to enlarge - 100-C_104-C-88-8 Protective Covers
  • Provides protection against unintended manual operation

  • For contactors and front-mounted auxiliary contacts, pneumatic timers, and latches
  • 100-C all 1 100-SCCA
    Cat. No. 100-SCCA
    Click to enlarge - 100-C_104-C-88-9 100-FA, -FB, -FC, -FP, -FL; 10 100-SCFA
    Cat. No. 100-SCFA
    Click to enlarge - 100-C_104-C-88-10 Reversing Power Wiring Kits
  • For reversing connection with a solid-state or thermal overload relay
  • 100-C09…C23 1 105-PW23
    100-C30…C37 105-PW37
    100-C43 105-PW43
    Cat. No. 105-PW23 100-C60…C97 105-PW85
    Click to enlarge - 100-C_104-C-88-11 DIN (#3) symmetrical hat rail
    35 x 7.5 x 1 m
    100-C 10 199-DR1
      
    ⋆ Must be ordered in multiples of package quantities.

    Marking Systems (For 100S-C09…C97 contactors)

      Description Pkg. Qty.⋆  Cat. No.
    Click to enlarge - 100-C_104-C-89-2 Label Sheet
    105 self-adhesive paper labels each, 6 x 17 mm
    10 100-FMS
    Click to enlarge - 100-C_104-C-89-3 Marking Tag Sheet
    160 perforated paper labels each, 6 x 17 mm, to be used with a transparent cover
    10 100-FMP
    Transparent Cover
    To be used with marking tag sheets
    100 100-FMC
    Click to enlarge - 100-FMA1 Marking Tag Adapters
    To be used with marking tag: System V4/V5
    100 100-FMA1
    Marking Tag Adapters
    To be used with marking tag: System 1492 W
    100 100-FMA2
      
    ⋆ Must be ordered in multiples of package quantities.

    Terminal Kits (For 100S-C09…C97 contactors)

      Description Max. Current Ratings and Wire Sizes Pkg. Qty.⋆  Cat. No.
    Click to enlarge - 100-C_104-C-90-1 Stab Connector Kit
    Dual stab (0.250 in.) for 100-C coil terminals
    For 100-C09…C97 contactors
    20 199-SC2
    Click to enlarge - 100-C_104-C-90-2 Stab Connector Kit
    Dual stab (0.250 in.) for 100-C power terminals
    For 100-C09…C23 contactors
    100 199-SC10
    Click to enlarge - 100_CTN23 3-Pole Terminal Lug Kit
    For Cat. No. 100-C09…C23 (Line side)
    IEC @ 40 °C
    IEC @ 40 °C
    UL/CSA (Encl.)
    45 A (4…16 mm2‡ , fine stranded w/ferrule)
    45 A (4…25 mm2, coarse stranded/solid)
    40 A (#10…4 AWG, stranded/solid)
    1 100-CTN23
    3-Pole Terminal Lug Kit
    For Cat. No. 100-C09…C23 (Load side)
    IEC @ 40 °C
    IEC @ 40 °C
    UL/CSA (Encl.)
    45 A (4…16 mm2‡ , fine stranded w/ferrule)
    45 A (4…25 mm2, coarse stranded/solid)
    40 A (#10…4 AWG, stranded/solid)
    1 100-CTL23
    3-Pole Terminal Lug Kit
    For Cat. No. 100-C30…C37 (Line and load side)
    IEC @ 40 °C
    IEC @ 40 °C
    UL/CSA (Encl.)
    60 A (4…16 mm2‡ , fine stranded w/ferrule)
    60 A (4…25 mm2, coarse stranded/solid)
    55 A (#10…4 AWG, stranded/solid)
    1 100-CT37
    Click to enlarge - 100_CT43 1-Pole Terminal Lug Kit
    For Cat. No. 100-C43
    IEC @ 40 °C
    IEC @ 40 °C
    UL/CSA (Encl.)
    90 A (6…35 mm2, fine stranded w/ferrule)
    90 A (6…50 mm2, coarse stranded/solid)
    75 A (#8…2 AWG, stranded/solid)
    3 100-CT43
    1-Pole Terminal Lug Kit
    For Cat. No. 100-C60…C97
    IEC @ 40 °C
    IEC @ 40 °C
    UL/CSA (Encl.)
    130 A (10…70 mm2, fine stranded w/ferrule)
    130 A (10…95 mm2, coarse stranded/solid)
    130 A (#8…2/0 AWG, stranded/solid)
    3 100-CT85
    Click to enlarge - 100CP23 3-Pole Paralleling Kit
    For Cat. No. 100-C09…C23
    IEC @ 40 °C
    IEC @ 40 °C
    UL/CSA (Encl.)
    100 A (35…70 mm2, fine stranded w/ferrule)
    100 A (35…95 mm2, coarse stranded/solid)
    100 A (#0…2/0 AWG, stranded/solid)
    2 100-CP23
    3-Pole Paralleling Kit
    For Cat. No. 100-C30…C37
    IEC @ 40 °C
    IEC @ 40 °C
    UL/CSA (Encl.)
    150 A (35…70 mm2, fine stranded w/ferrule)
    150 A (35…95 mm2, coarse stranded/solid)
    150 A (#0…2/0 AWG, stranded/solid)
    2 100-CP37
      
    ⋆ Must be ordered in package quantities.
    ‡ 16 mm2 max. according to IEC 60947; actual max. 25 mm2.

    Specifications

      100S/104S-C
      09 12 16 23 30 37 43 60 72 85 97
    Coil Type : Conventional X X X X X X X X X X X
        Electronic — EI
    Conductor Cross Sections - Main Contacts
    Terminal type
    Click to enlarge - 140M-29-1 ⋆  Click to enlarge - 140M-29-2 ‡  Click to enlarge - 140M-29-2 § 
    Click to enlarge - 140M-29-4   (1) conductor
    (2) conductors
    [mm2]
    [mm2]
    1…4
    1…4
    2.5…10
    2.5…10
    2.5…16
    2.5…10
    2.5…35
    2.5…25
    2.5…35
    2.5…35
    Click to enlarge - 140M-29-5 Click to enlarge - 140M-29-6 (1) conductor
    (2) conductors
    [mm2]
    [mm2]
    1.5…6
    1.5…6
    2.5…16
    2.5…16
    2.5…25
    2.5…16
    2.5…50
    2.5…35
    2.5…50
    2.5…50
    Click to enlarge - Contactors_2-30-9 b max. [mm]
    c max. [mm]
    s max. [mm]
    Æ min. [mm]
    Recommended torque [N•m]   1.5…2.5 2.5…3.5 2.5…3.5 4.5…6
    Cross section per UL/CSA [AWG]   16…10 14…4 14…4 14…1
    Recommended torque [lb•in]   13.3…22 22…31 22…31 40…53
    With terminal lug kit    
    Cross section per UL/CSA [AWG]  
    Recommended torque [lb•in]  
    With Frame Terminal Block        
    Click to enlarge - 140M-29-4   top opening
    bottom opening
    [mm2]
    [mm2]
    Click to enlarge - 140M-29-5 Click to enlarge - 140M-29-6 top opening
    bott. opening
    [mm2]
    [mm2]
    Click to enlarge - Contractors2_30-13 b max.
    s top
    s bottom
    [mm]
    [mm]
    [mm]
    Recommended torque [N•m]  
    Cross section per UL/CSA top [AWG]  
    bottom [AWG]  
    Recommended torque [lb•in]  
      
    ⋆ Pozidriv No. 2 / Blade No. 3 screw
    ‡ Pozidriv No. 2 / Blade No. 4 screw
    § Hexagonal socket screw

      100S-D
    115 115 140 180 210 250 300 420 630 860
    Coil Type : Conventional X X X
    Electronic — EI X X X X X X X X X
    Conductor Cross Sections - Main Contacts
    Terminal type
    Click to enlarge - Contractors2_31-1 Click to enlarge - Contractors2_31-1 Click to enlarge - Contractors2_31-1 Click to enlarge - Contractors2_31-1
    Click to enlarge - 140M-29-4   (1) conductor
    (2) conductors
    [mm2]
    [mm2]





    Click to enlarge - 140M-29-5 Click to enlarge - 140M-29-6 (1) conductor
    (2) conductors
    [mm2]
    [mm2]





    Click to enlarge - Contactors_2-30-9 Click to enlarge - 140M-29-6 b max. [mm] 20 25 30 52 52
    Click to enlarge - 140M-29-6 c max. [mm] 10 12.5 15 22 22
    Click to enlarge - 140M-29-6 s max. [mm] 5 5 6 2 x 8 2 x 8
    Click to enlarge - 140M-29-6 Æ min. [mm] 6.1 8.3 10.5 13 13
    Recommended torque Click to enlarge - 140M-29-6 [Nm] 8…10 10…12 16 68 68
    Cross section per UL/CSA Click to enlarge - 140M-29-6 [AWG]
    Recommended torque Click to enlarge - 140M-29-6 [lb-in] 70…90 90…110 130…150 600 600
    With terminal lug kit Click to enlarge - 140M-29-6 100-DL110§  100-DLE110§  100-DL180§  100-DL420§  100-DL630 100-DL860
    Cross section per UL/CSA Click to enlarge - 140M-29-6 [AWG] 8…2/0 8…2/0 6…300 MCM (2x) 4…350 MCM (2X) 2/0…
    500MCM
    (4X) 2/0…
    500MCM
    Recommended torque Click to enlarge - 140M-29-6 [lb-in] 90 90 250 250 400 400
    With Frame Terminal Block     Click to enlarge - 140M-29-6 100-DTB110§  100-DTB180§  100-DTB420⋆ 
    Click to enlarge - 140M-29-4   top opening
    bottom opening
    [mm2]
    [mm2]
    16…35
    16…70
    16…35
    16…95
    25…240∆ 
    25…240
    Click to enlarge - 140M-29-5 Click to enlarge - 140M-29-6 top opening
    bott. opening
    [mm2]
    [mm2]
    16…50
    16…95
    16…50
    16…120
    25…300
    25…300
    Click to enlarge - Contractors2_30-13   b max.
    s top
    s bottom
    [mm]
    [mm]
    [mm]
    16
    3…9
    3…12
    20
    3…9
    3…14
    25
    4…20
    4…20
    Recommended torque Click to enlarge - 140M-29-6 [Nm] 8…10 10…12 20…25
    Cross section per UL/CSA top Click to enlarge - 140M-29-6 [AWG] 6…1 / 0 AWG 6…1 / 0 AWG 4 AWG…600 MCM
    bottom Click to enlarge - 140M-29-6 [AWG] 6…3 / 0 AWG 6 AWG…250 MCM 4 AWG…600 MCM
    Recommended torque Click to enlarge - 140M-29-6 [lb-in] 70…90 90…110 180…220
         
      ⋆ Pozidriv No. 2 / Blade No. 3 screw
    § Hexagonal socket screw
    ♣ Hexagonal screw
    ∆ 25…95 mm2 with sleeve per DIN 46228

    Coil Data

      100S/104S-C
      09 12 16 23 30 37 43 60 72 85 97
    Coil Type Conventional X X X X X X X X X X X
    Electronic — EI
    Operating Limits
    50 Hz, 60 Hz, 50/60 Hz pick-up [x Us] 0.85…1.1 0.85….1.1
    dropout [x Us] 0.3…0.6 0.3…0.6
    DC (conventional) pick-up [x Us] 0.8…1.1 0.8…1.1
    dropout [x Us] 0.1…0.6 0.1…0.6
    DC (electronic) pick-up [x Us] 0.7…1.25
    dropout [x Us] 0.1…0.5
    Coil Consumption
    50 Hz, 60 Hz, 50/60 Hz pick-up [VA/W] 70/50 70/50 80/60 130/90 200/110
    hold-in [VA/W] 8/2.6 9/3 9/3 10/3.2 16/4.5
    DC (conventional) pick-up [W] 6.5 9.2 9.2 10.1 200
    hold-in [W] 6.5 9.2 9.2 10.1 4.5
    DC (electronic) pick-up (avg/peak) [W] 10/22 10/22 10.1
    hold-in [W] 1.5 10.1
    Operating Times
    AC closing delay [ms] 15…30 15…30 15…30 15…30 20…40
    opening delay [ms] 10…60 10…60 10…60 10…60 10…60
    With RC module opening delay [ms] 10…60 10…60 10…60 10…60 10…60
    DC (conventional) closing delay [ms] 40…70 40…70 50…80 50…80 20…40
    opening delay [ms] 7…15 7…15 7…15 7…15
    With integ. diode opening delay [ms] 14…20 17…23 17…23 17…23 £ 220V 20…35
    With external diode opening delay [ms] 70…95 80…125 80…125 80…125 £ 220V 80…125
    DC (electronic) closing delay [ms] 20…40
    opening delay [ms] 20…40
    Max. Ripple ± 15%
      

      100S-D
    115 140/180 95 110 140 180 210 250 300 420 630 860
    Coil Type Conventional X X
    Electronic — EI X X X X X X X X X X
    Operating Limits
    50 Hz, 60 Hz, 50/60 Hz pick-up [x Us] 0.85…1.1 0.85…1.1 0.8…1.1
    dropout [x Us] 0.3…0.6 0.3…0.5 0.3…0.8
    DC control pick-up [x Us] 0.85…1.1 0.85…1.1 0.85…1.1
    dropout [x Us] 0.3…0.6 0.3…0.5 0.3…0.8
    Coil Consumption
    50 Hz, 60 Hz, 50/60 Hz pick-up [VA/W] 650/310 380/240⋆  490/270⋆  1915/1720⋆ 
    hold-in [VA/W] 50/10 13/6 18/7 33/30
    DC control pick-up [W] 540 265⋆  340⋆  1980⋆ 
    hold-in [W] 8 6 7 30
    Operating Times
    AC closing delay [ms] 20…47 20…45 60…100
    opening delay [ms] 6…12 25…110 70…145
    With RC module opening delay [ms] 9…18
    DC closing delay [ms] 27…47 25…50 60…100
    opening delay [ms] 12…20 35…110 70…145
    With integrated diode opening delay [ms] 12…20
    With external diode opening delay [ms]
      
    ⋆ Electronic coil drives are designed to minimize power requirements, but this control may exhibit a higher inrush (540 W, < 10 ms) when energizing. This must be taken into account for the proper sizing of supply devices, all-or-nothing relays and cross-sections of coil supply lines. Please contact your local Rockwell Automation sales office or Allen-Bradley distributor for detailed information.

    Bulletin 100S-C/104S-C Approximate Dimensions

    Bulletin 100S-C/104S-C Contactors and Accessories

    Approximate dimensions are shown in millimeters (inches) and not intended for manufacturing purposes.

    Click to enlarge - 100C_104C-123-2


    Mounting
    Position


    Click to enlarge - mcsc_v
    AC contactors and DC contactors with electronic coils


    Click to enlarge - mcsc_y
    DC contactors


    AC Contactors and DC Contactors with Electronic Coils

    Cat. No. a b c c1 c2 Æd d1 d2
    100S-C09…100S-C23 45
    (1-25/32)
    81
    (3-3/16)
    119.5
    (4-3/4)
    114.5
    (4-43/64)
    6
    (15/64)
    2-4.5
    (2-3/16)
    60
    (2-23/64)
    35
    (1-3/8)
    100S-C30, 100S-C37 45
    (1-25/32)
    81
    (3-3/16)
    136.5
    (5-37/64)
    131.6
    (5-11/32)
    6.5
    (1/4)
    2-4.5
    (2-3/16)
    60
    (2-23/64)
    35
    (1-3/8)
    100S-C43 54
    (2-1/8)
    81
    (3-3/16)
    139.5
    (5-11/16)
    134.6
    (5-29/64)
    6.5
    (1/4)
    2-4.5
    (2-3/16)
    60
    (2-23/64)
    45
    (1-25/32)
    100S-C60…100S-C97 72
    (2-53/64)
    122
    (4-51/64)
    156
    (6-11/32)
    150.5
    (6-1/8)
    8.5
    (21/64)
    4-5.4
    (4-7/32)
    100
    (3-15/16)
    55
    (2-11/64)
      

    DC Contactors

    Cat. No. a b c c1 c2 Æd d1 d2
    100S-C09Z...100S-C16Z 45
    (1-25/32)
    81
    (3-3/16)
    145.5
    (5-49/64)
    140.5
    (5-37/64)
    6
    (15/64)
    2-4.5
    (2-3/16)
    60
    (2-23/64)
    35
    (1-3/8)
    100S-C23Z 45
    (1-25/32)
    81
    (3-3/16)
    162.5
    (6-7/16)
    158
    (6-1/4)
    6
    (15/64)
    2-4.5
    (2 -3/16)
    60
    (2-23/64)
    35
    (1-3/8)
    100S-C30Z...100S-C37Z 45
    (1-25/32)
    81
    (3-3/16)
    180.5
    (7-5/32)
    175.5
    (6-61/64)
    6.5
    (1/4)
    2-4.5
    (2-3/16)
    60
    (2-23/64)
    35
    (1-3/8)
    100S-C43Z 54
    (2-1/8)
    81
    (3-3/16)
    183.5
    (7-17/64)
    179
    (7-3/32)
    6.5
    (1/4)
    2-4.5
    (2-3/16)
    60
    (2-23/64)
    45
    (1-25/32)
    100S-C60D...100S-C97D 72
    (2-53/64)
    122
    (4-51/64)
    156
    (6-11/32)
    150.5
    (6-1/8)
    8.5
    (21/64)
    4-5.4
    (4-7/32)
    100
    (3-15/16)
    55
    (2-11/64)
      

    Accessories

    Contactors with mm (inches)
    Auxiliary contact block for side mounting 1- or 2-pole a + 9 (a + 23/64)
    Electronic Timing Module on coil terminal side b + 24 (b + 15/16)
    Mechanical Interlock on side of contactor a + 9 (a + 23/64)
    Interface Module on coil terminal side b + 9 (b + 23/64)
    Surge Suppressor on coil terminal side b + 3 (b + 1/8)
    Labeling with ⋆  label sheet
    marking tag sheet with clear cover
    marking tag adapter for System V4 / V5
    marking tag adapter for System Bul. 1492W
    + 0
    + 0
    + 5.5
    + 5.5
    (+ 0)
    (+ 0)
    (+ 7/32)
    (+ 7/32)