Description
|
Connection Diagrams
|
For Use With
|
Cat. No.
|
|
Pneumatic Timing Modules Pneumatic timing element contacts switch after the delay time. The contacts on the main control relay continue to operate without delay.
|
On-Delay 0.3…30 s Range
|
|
100-C or 700-CF with AC coils or DC electronic coils
|
100-FPTA30
|
| 1.8…180 s Range
|
100-FPTA180
|
Off-Delay 0.3…30 s Range
|
|
100-C all, 700-CF all
|
100-FPTB30
|
| 1.8…180 s Range
|
100-FPTB180
|
|
Electronic Timing Modules — On-Delay Delay of the contactor or control relay solenoid. The contactor or control relay is energized at the end of the delay time.
|
On-Delay 1…30 s Range
|
|
100-C or 700-CF with 24…48V DC coils
|
100-ETA3
|
| 1…30 s Range
|
100-ETA30
|
| 10…180 s Range
|
100-ETA180
|
110…240V, 50/60 Hz 110…250V DC
|
|
On-Delay 0.1…3 s Range
|
|
100-C or 700-CF with 24…48V DC coils
|
100-ETAZJ3
|
| 1…30 s Range
|
100-ETAZJ30
|
| 10…180 s Range
|
100-ETAZJ180
|
24…48V DC
|
|
|
Electronic Timing Modules — Off-Delay Delay of the contactor or control relay solenoid. After interruption of the control signal, the contactor or control relay is deenergized at the end of the delay time.
|
Off-Delay 0.3…3 s Range
|
|
100-C09…C37 or 700-CF with 24V 50/60 Hz coils
|
100-ETBKJ3
|
| 1…30 s Range
|
100-ETBKJ30
|
| 10…180 s Range
|
100-ETBKJ180
|
24V, 50/60 Hz
|
|
Off-Delay 0.3…3 s Range
|
100-C or 700-CF with 110…240V 50/60 Hz coils
|
100-ETB3
|
| 1…30 s Range
|
100-ETB30
|
| 10…180 s Range
|
100-ETB180
|
110…240V, 50/60 Hz
|
|
|
Electronic Timing Modules Delay of the contactor solenoid. Contactor K 3 (Y) is de-energized (off) and K 2 (D) is energized (on) after the end of the set Y end time. (Switching delay at 50 ms.) Continuous adjustment range High repeat accuracy
|
Transition Time Y Contactor 1…30 s Range
110…240V, 50/60 Hz
|
|
100-C with 110…240V, 50/60 Hz coils
|
100-ETY30
|
|
Mechanical Interlocks For interlocking of two contactors. Common interlock for all Bul. 100-C contactor sizes Interlocking of different sizes possible Mechanical and electrical interlocking possible in one module by means of integrated auxiliary contacts 9 mm dovetail connector included
|
Mechanical only, without auxiliary contacts
|
|
100-C (except 100-C40, -C90)
|
100-MCA00
|
| Mechanical/ electrical interlock with 2 N.C. auxiliary contacts
|
|
100-C (except 100-C40, -C90)
|
100-MCA02
|
|
Mechanical Latch Following contactor latching, the contactor coil is immediately de-energized (off) by the N.C. auxiliary contact (65-66). Electrical or manual release 1 N.O. + 1 N.C. auxiliary contacts Suitable for all Bul. 100-C contactor sizes, 9…97 A
|
Maximum command duration 0.03…10 s
|
|
100-C with AC or 24V DC electronic coils (except 100-C90)
|
100-FL11Ä
|
|
|
| Package Quantity = 1
|
| [V]⋆
|
24V
|
48V
|
100V
|
110V
|
120V
|
230-240V
|
240V
|
277V
|
380-400V
|
400-415V
|
440V
|
480V
|
| AC, 50 Hz
|
K
|
Y
|
KP
|
D
|
—
|
VA
|
T
|
—
|
N
|
G
|
B
|
—
|
| AC, 60 Hz
|
J
|
—
|
—
|
—
|
D
|
—
|
A
|
T
|
—
|
—
|
N
|
B
|
|
|
| ⋆ For special voltages, please contact your local Rockwell Automation sales office or Allen-Bradley distributor.
|
|
Description
|
Voltage Range
|
Connection Diagrams
|
For Use With
|
Cat. No.
|
DC Interface (Electronic) Interface between the DC control signal (PLC) and the AC operating mechanism of the contactor. Requires no additional surge suppression on the relay coils
|
Input: 12V DC Output: 110…240V AC
|
|
100-C with AC coils 110…240V AC
|
100-JE12
|
Input: 18…30V DC Output: 110…240V AC
|
100-JE
|
Input: 48V DC Output: 110…240V AC
|
100-JE48
|
|
Surge Suppressors For limitation of coil switching transients. Plug-in, coil mounted. Suitable for 100-C contactor sizes, 9…97 A. RC, varistor, and diode versions.
|
RC Module AC operating mechanism
|
24…48V AC, 50/60 Hz
|
|
100-C with AC coils
|
100-FSC48
|
| 110…280V AC, 50/60 Hz
|
100-FSC280
|
| 380…480V AC, 50/60 Hz
|
100-FSC480
|
Varistor Module AC/DC operating mechanism
|
12…55V AC/ 12…77V DC
|
|
100-C with AC coils or 100-C09…-C43 with DC coils
|
100-FSV55
|
| 56…136V AC/ 78…180V DC
|
100-C with AC coils or 100-C09…-C43 with DC coils
|
100-FSV136
|
| 137…277V AC/ 181…350V DC
|
100-C with AC coils or 100-C09…-C43 with DC coils
|
100-FSV277
|
| 278…575V AC
|
100-C with AC coils or 100-C09…-C43 with DC coils
|
100-FSV575
|
Diode Module DC operating mechanism
|
12…250V DC
|
|
100-C09…-C43 with DC coils
|
100-FSD250
|
|
|
|
|
Description
|
For Use With
|
Pkg. Quantity⋆
|
Cat. No.
|
|
Dovetail Connectors For use in contactor and starter assemblies. Single Connector — 0 mm Spacing
|
100-C
|
10
|
100-S0
|
| Cat. No. 100-S0
|
Dovetail Connectors For use in contactor and starter assemblies. Dual Connector — 9 mm Spacing
|
100-S9
|
|
Protective Covers Provides protection against unintended manual operation For contactors and front-mounted auxiliary contacts, pneumatic timers, and latches
|
100-C all
|
1
|
100-SCCA
|
| Cat. No. 100-SCCA
|
|
100-FA, -FB, -FC, -FP, -FL;
|
10
|
100-SCFA
|
| Cat. No. 100-SCFA
|
|
Reversing Power Wiring Kits For reversing connection with a solid-state or thermal overload relay
|
100-C09…C23
|
1
|
105-PW23
|
| 100-C30…C37
|
105-PW37
|
| 100-C43
|
105-PW43
|
| Cat. No. 105-PW23
|
100-C60…C97
|
105-PW85
|
|
DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m
|
100-C
|
10
|
199-DR1
|
|
|
| ⋆ Must be ordered in multiples of package quantities.
|
|
|
Description
|
Pkg. Qty.⋆
|
Cat. No.
|
|
Label Sheet 105 self-adhesive paper labels each, 6 x 17 mm
|
10
|
100-FMS
|
|
Marking Tag Sheet 160 perforated paper labels each, 6 x 17 mm, to be used with a transparent cover
|
10
|
100-FMP
|
Transparent Cover To be used with marking tag sheets
|
100
|
100-FMC
|
|
Marking Tag Adapters To be used with marking tag: System V4/V5
|
100
|
100-FMA1
|
Marking Tag Adapters To be used with marking tag: System 1492 W
|
100
|
100-FMA2
|
|
|
| ⋆ Must be ordered in multiples of package quantities.
|
|
|
Description
|
Max. Current Ratings and Wire Sizes
|
Pkg. Qty.⋆
|
Cat. No.
|
|
Stab Connector Kit Dual stab (0.250 in.) for 100-C coil terminals For 100-C09…C97 contactors
|
20
|
199-SC2
|
|
Stab Connector Kit Dual stab (0.250 in.) for 100-C power terminals For 100-C09…C23 contactors
|
100
|
199-SC10
|
|
3-Pole Terminal Lug Kit For Cat. No. 100-C09…C23 (Line side)
|
IEC @ 40 °C IEC @ 40 °C UL/CSA (Encl.)
|
45 A (4…16 mm2 , fine stranded w/ferrule) 45 A (4…25 mm2, coarse stranded/solid) 40 A (#10…4 AWG, stranded/solid)
|
1
|
100-CTN23
|
3-Pole Terminal Lug Kit For Cat. No. 100-C09…C23 (Load side)
|
IEC @ 40 °C IEC @ 40 °C UL/CSA (Encl.)
|
45 A (4…16 mm2 , fine stranded w/ferrule) 45 A (4…25 mm2, coarse stranded/solid) 40 A (#10…4 AWG, stranded/solid)
|
1
|
100-CTL23
|
3-Pole Terminal Lug Kit For Cat. No. 100-C30…C37 (Line and load side)
|
IEC @ 40 °C IEC @ 40 °C UL/CSA (Encl.)
|
60 A (4…16 mm2 , fine stranded w/ferrule) 60 A (4…25 mm2, coarse stranded/solid) 55 A (#10…4 AWG, stranded/solid)
|
1
|
100-CT37
|
|
1-Pole Terminal Lug Kit For Cat. No. 100-C43
|
IEC @ 40 °C IEC @ 40 °C UL/CSA (Encl.)
|
90 A (6…35 mm2, fine stranded w/ferrule) 90 A (6…50 mm2, coarse stranded/solid) 75 A (#8…2 AWG, stranded/solid)
|
3
|
100-CT43
|
1-Pole Terminal Lug Kit For Cat. No. 100-C60…C97
|
IEC @ 40 °C IEC @ 40 °C UL/CSA (Encl.)
|
130 A (10…70 mm2, fine stranded w/ferrule) 130 A (10…95 mm2, coarse stranded/solid) 130 A (#8…2/0 AWG, stranded/solid)
|
3
|
100-CT85
|
|
3-Pole Paralleling Kit For Cat. No. 100-C09…C23
|
IEC @ 40 °C IEC @ 40 °C UL/CSA (Encl.)
|
100 A (35…70 mm2, fine stranded w/ferrule) 100 A (35…95 mm2, coarse stranded/solid) 100 A (#0…2/0 AWG, stranded/solid)
|
2
|
100-CP23
|
3-Pole Paralleling Kit For Cat. No. 100-C30…C37
|
IEC @ 40 °C IEC @ 40 °C UL/CSA (Encl.)
|
150 A (35…70 mm2, fine stranded w/ferrule) 150 A (35…95 mm2, coarse stranded/solid) 150 A (#0…2/0 AWG, stranded/solid)
|
2
|
100-CP37
|
|
|
| ⋆ Must be ordered in package quantities.
|
| 16 mm2 max. according to IEC 60947; actual max. 25 mm2.
|