Bulletin 100S-D IEC Safety Contactors

Introduction Standards Compliance and Certifications Product Selection Bulletin 100S-D/104S-D Accessories Bulletin 100S-D Approximate Dimensions
Product Selection

3-Pole AC-Operated Contactors

Ie [A] Switching of 3-phase motors AC-2, AC-3 Coil Type Auxiliary contacts Cat. No.♦ 
60 °C 40 °C kW (50 Hz)⋆  Hp (60 Hz) N.O. N.C.‡ 
AC-3 AC-1 230V 400V 415V 500V 690V 1000V 200V 230V 460V 575V Click to enlarge - 100M-66-3a Click to enlarge - 100S-D-80-6
115 250 37 63 66/75♣  80 111 63 40 40 75 100 Conventional 2 2 100S-D115Ä22BC
115 250 37 63 66/75♣  80 111 63 40 40 75 100 Electronic 2 2 100S-D115Ä22BC
140 250 45 78 82/90♣  80/100§  110/132§  75 40 50 100 125 Conventional 2 2 100S-D140Ä22BC
140 250 45 78 82/90♣  80/100§  110/132§  75 40 50 100 125 Electronic 2 2 100S-D140Ä22BC
180 250 55 101 100♣  90/125§  132/160§  90 50 60 150 150 Conventional 2 2 100S-D180Ä22BC
180 250 55 101 100♣  90/125§  132/160§  90 50 60 150 150 Electronic 2 2 100S-D180Ä22BC
210 350 63 118 110♣  205 200 110 60 75 150 200 Electronic 2 2 100S-D210Ä22BC
250 350 80 140 150♣  250 250 133 75 100 200 250 Electronic 2 2 100S-D250Ä22BC
300 450 90 170 160♣  290 300 160 100 125 250 300 Electronic 2 2 100S-D300Ä22BC
420 540 132 238 250 420 425 220 150 175 350 400 Electronic 2 2 100S-D420Ä22BC
630 800 200 355 355 500 500 200 250 500 600 Electronic 2 2 100S-D630Ä22BC
860 1000 250 500 500 500 600 250 300 600 700 Electronic 2 2 100S-D860Ä22BC
  
⋆ Preferred values according to IEC 60072-1.
‡ The N.C. contacts meet IEC 60947-4 Annex F requirements for mirror contact performance. The N.C. mirror contacts are wired in series or parallel and must be used as monitoring contacts with feedback to the safety circuit.
§ Higher kW rating only applies to contactors with electronic coil.
♦ If standard cross-stamped front-mount auxiliary contacts are required, remove the letter "B" before the letter "C" in the cat. no. Example: Cat. No. 100S-D95Ä22BC becomes Cat. No. 100S-D95Ä22C.
♣ 415V: Values for AC-3 and AC-4 lifespan -25%

Ä Coil Voltage Codes: see

3-Pole DC-Operated Contactors

Ie [A] Switching of 3-phase motors AC-2, AC-3 Auxiliary contacts Coil Type Conventional Coil
Cat. No.‡ 
Electronic Coil
Cat. No.♦ 
60 °C 40 °C kW (50 Hz) ⋆  Hp (60 Hz) N.O. N.C. ‡  ⋆ 
AC-3 AC-1 230V 400V 415V 500V 690V 1000V 200V 230V 460V 575V Click to enlarge - 100M-66-3a Click to enlarge - 100S-D-80-6
115 250 37 63 75 80 111 63 40 40 75 100 3 2/1L Conventional 100S-D115Ä33LC§  ‡  100S-D115Ä22BC
140 250 45 78 75 80/100♣  110/132♣  75 40 50 100 125 3 2/1L Conventional 100S-D140Ä33LC§  ‡  100S-D140Ä22BC
180 250 55 101 100 90/125♣  132/160♣  90 50 60 150 150 3 2/1L Conventional 100S-D180Ä33LC§  ‡  100S-D180Ä22BC
210 350 63 118 110 205 200 110 60 75 150 200 2 2 Electronic 100S-D210Ä22BC
250 350 80 140 150 250 250 133 75 100 200 250 2 2 Electronic 100S-D250Ä22BC
300 450 90 170 160 290 300 160 100 125 250 300 2 2 Electronic 100S-D300Ä22BC
420 540 132 238 250 420 425 220 150 175 350 400 2 2 Electronic 100S-D420Ä22BC
630 800 200 355 355 500 500 200 250 500 600 2 2 Electronic 100S-D630Ä22BC
860 1000 250 500 500 500 600 250 300 600 700 2 2 Electronic 100S-D860Ä22BC
  
⋆ Preferred values according to IEC 60072-1.
‡ The N.C. contacts meet IEC 60947-4 Annex F requirements for mirror contact performance. The N.C. mirror contacts are wired in series or parallel and must be used as monitoring contacts with feedback to the safety circuit.
§ For conventional DC coil only. The pickup winding must be interconnected with the N.C. late-breaking auxiliary contacts.
♣ Higher kW rating only applies to contactors with electronic coil.
♦ If standard cross-stamped front-mount auxiliary contacts are required, remove the letter "B" before the letter "C" in the Cat. No. Example: Cat. No. 100S-D95Ä22BC becomes Cat. No. 100S-D95Ä22C.

Ä Coil Voltage Codes

Conventional Coil [V] 24 48 100 110 120 200 208 220
…230
230 240 277 380
…400
415 440 480 500 550 600
100S-D115…100S-D180 AC, 50 Hz K Y D A T N B G M C
AC, 60 Hz J X D H A T N B C
100S-D115 AC, 50/60 Hz KP KN KG KL KF KA KT
  

Electronic Coil
w/ PLC Interface♣ 
[V] 24 42…64 100 110…
130
200 208…
277
200…
220
230…
250
277 380…
415
380…
440
440…
480
380…
500
500
100S-D115…100S-D300 AC, 50/60 Hz EJ∆  EY EP ED EG EA VN EN
100S-D420 AC, 50/60 Hz EP ED EG EA EN
100S-D630…100S-D860 AC, 50/60 Hz EP ED EG EG EA ET EN EB EM
  

Conventional Coil [V] 24 48 110 125 220 250
100S-D115…100S-D180 §  DC ZJ ZY ZD ZS ZA ZT
  

Electronic Coil
w/ EI Interface ∆ 
[V] 24 48…72 110…130 200…255
100S-D115…100S-D300 DC EZJ EZY EZD EZA
100S-D420 DC EZD EZA
100S-D630…860 DC ED EA
  

∆ Signal voltage of the cat. no. 100S-S… electronic interface Ue: 24V DC/Ie: 15 mA
Pick-up voltage: 13.0V DC…30.2V DC
Drop-out voltage: -3.0V DC…+5.0V DC