1336 REGEN Line Regenerative Package

1336 REGEN Line Regeneration Package

Click to enlarge - 1336r

Standards Compliance

The 1336 REGEN conforms to the following:

Conformity to: Standard Product
UL Listed ü
CSA Certified (c-UL) ü
 

Description

The 1336 REGEN Line Regeneration Package can be configured to address the needs of two operating modes; the Regenerative DC Bus Supply mode and the Regenerative Brake mode. The selected operating mode will result in different implementation costs and hardware requirements.

In the Regenerative Brake Mode the 1336 REGEN is used to remove braking energy from the DC bus and return it back to the three-phase AC utility. In many regenerative applications, the 1336 REGEN offers an energy-efficient alternative to dynamic brakes and chopper module/resistor combinations.

In the Regenerative DC Bus Supply Mode, the 1336 REGEN supplies both motoring and regenerative current to one or more DC input drives.

When the net power requirements of the attached common bus drives demand motoring power, energy flows from the utility to the common DC bus. When the net power requirements of the attached common bus drives demand regenerative power, energy flows from the common DC bus to the utility.


Catalog Number Explanation

1336R - VB   180 - AA - HAB
a   b   c   d   e ¬ 

a
Product
Code Type
1336R 1336 REGEN

b
Drive Rating
Code Input Voltage Ph. Hz
VB 380…480V AC 3 50/60

c
Rating
Code kW (Hp)
048 38.4 (48.2)
078 62.3 (78.2)
180 143.7 (180.4)

d
Enclosure
Code Rating
AA IP 20 (NEMA Type 1)
AN IP 00 (Open)

e
HIM
Code Description
HAB Blank - No Functionality
HAP Programmer Only
¬ IP20 (NEMA Type 1) - Field must be specified.

Product Selection

The 1336 REGEN Line Regeneration Package consists of:


When configured as a regenerative brake, a 3% 1321 line reactor will be required to limit current harmonics on the AC line and to provide impedance between the regenerative brake and the attached drives. When configured as a regenerative DC bus supply, a 10% line reactor and an EMI filter/3% reactor combination for high frequency noise attenuation will be required.

The 3 or 10% 1321 line reactor and EMI filter are not included in the line regeneration package and must be ordered separately.


1336 REGEN Operating Mode Selection
Application Requirements Regen DC Bus Supply Mode Regen Brake Mode
Low Current Harmonics X  
Multiple Drive Applications X  
High Power Factor ¬  X
Equal Braking and Motoring HP ¬  X
Less Braking Than Motoring HP ¬  X
Single Drive Application ¬  X
Intermittent Braking or Low Braking Duty Cycle ¬  X
  
¬ The Regenerative Bus Supply Mode can also be used for these applications, but will result in a more complex hardware configuration and a higher total system cost. Regenerative Bus Supply operation requires a custom Bulletin 1321 10% line reactor, while Regenerative Brake operation requires a standard Bulletin 1321 3% line reactor. The mode of operation is selected by a parameter setting in the 1336 REGEN Converter.

1336 REGEN Frame Designations
1336 REGEN Converter Rating 1336 REGEN Precharge Rating
Frame Reference AC Input kW Amp Rating AC Input kW Amp Rating
B 38.4 48.2 38.4 48.2
C 62.3 78.2 62.3 78.2
D 143.7 180.4 143.7 180.4
  

1336 REGEN Brake Example

Click to enlarge - regen_1


1336 REGEN Bus Supply Example

Click to enlarge - regen_2


1336 REGEN Package
(includes Converter & Precharge Module)
Frame Nominal Brake Rating IP00 (Open)
No Enclosure
IP20
(NEMA Type 1)
General Purpose
Input Amps Output kW Code Code
B 48.2 38.4 1336R-VB048-AN 1336R-VB048-AA
C 78.2 62.3 1336R-VB078-AN 1336R-VB078-AA
D 180.4 143.7 1336R-VB180-AN 1336R-VB180-AA
 

1321 Line Reactors and EMI Filters

Refer to Line Reactor and Filter Selection for 1336 REGEN Package.

User Installed Options

Human Interface Module Option Kits
Description Used with … Cat. No.
IP 20 (NEMA Type 1) HIM
Blank - No Functionality
All Open Chassis and IP 20 (NEMA Type 1) converter ratings 1201-HAB
Programmer Only
1201-HAP
Option Cable Kit - Connect to HIM Cradle Port
0.33 Meters (1.1 Feet)
All HIMs not mounted on the converter chassis 1202-H03
1 Meter (3.3 Feet)
1202-H10
3 Meter (9.8 Feet)
1202-H30
9 Meter (29.5 Feet)
1202-H90
  

Gasket & Enclosure Kits
Description Cat. No. Cat. No.
Gasket Kits for mounting 1336 REGEN Converter Units in User Supplied IP 54 or 65 (NEMA Type 12 or 4) Encl. Frame B 1336-RF4
Frame C 1336-RF5
Frame D 1336-RF6
Enclosure Kits for 1336 REGEN Converter IP 20 (NEMA Type 1) Frame B 1336R-AA4
Frame C 1336R-AA5
Frame D 1336R-AA6
    

Factory Installed Options

Interface Options
Description Used with … Cat. Code
(Position e)
Human Interface Module, IP 20 (NEMA Type 1)
Blank - No Functionality
IP 00 (Open) and IP 20 (NEMA Type 1) Drives -HAB
Programmer Only
-HAP
  

Specifications

Electrical
AC Input Voltage Range: 380-480V AC, Three-Phase, +10%/–15% Nominal, 48-62Hz
90-115V AC, Single-Phase, ±10% Nominal, 48-62Hz
Control Output Specifications
Heat SinkTemperature Sensor
Contact Output Rating (max.):
The two temperature sensors trip if heat temperature exceeds 85°C.
Resistive Rating: 15A at 125V AC, 10A at 250V AC, 7A at 24V DC
Inductive Rating: 10A at 125V AC, 6A at 250V AC
Environmental Specifications
Ambient Operating Temperature: IP00 (Open): 0-50°C
IP20 (NEMA Type 1): 0-40°C
Storage Temperature: All Ratings -40 to +85°C
Relative Humidity: 5 to 95% non-condensing
Shock: 15G peak for 11ms duration (±1.0 ms)
Vibration: 0.152 mm (0.006 in.) displacement, 1G peak
ESD Susceptibility, IP20 (NEMA Type 1) Only: 15 kV
Protection
AC Input Overvoltage Trip: Factory Set to +15% of Nominal Line Voltage
Heatsink Over Temperature Trip: 100° C
1336R Converter Overcurrent Trip: Software Overcurrent Limit - Factory Set to 192% of AC Input Current
Hardware Overcurrent Limit - Factory Set to 245% of AC Input Current
Line Transients: Up to 6000 Volts Peak per ANSI C62.41-1991
Control Logic Noise Immunity: Showering Arc Transients Up to 1500 Volts Peak
Power Ride-Thru: 6 ms at Full Load
Control Logic Ride-Thru: 0.5 Sec. Minimum, 2 Sec. Typical
Protection - Regenerative DC Bus Supply Mode
Bus Overvoltage Trip: 670V DC at 380V AC Input, 850V DC at 480V AC Input
Bus Undervoltage Trip: 430V DC at 380V AC Input, 520V DC at 480V AC Input
Nominal Bus Voltage: 610V DC at 380V AC Input, 735V DC at 480V AC Input
 

Regenerative DC Bus Supply Operation Only - 380-480V AC Input
Rating Converter Converter Heat Sink Precharge Unit 10% Line Reactor Power Line Filter Package Total
48A 141W 820W 15W 186W 173W 1335W
78A 193W 1110W 29W 258W 236W 1826W
180A 522W 2664W 58W 474W 317W 4035W
 

Regenerative Brake Operation Only - 380-480V AC Input
Rating Converter Converter Heat Sink Precharge Unit 3% Line Reactor Package Total
48A 141W 656W 15W 65W 877W
78A 193W 888W 29W 84W 1194W
180A 522W 2131W 58W 168W 2879W
 

Altitude Derating

Click to enlarge - 36r_derate

1336 REGEN Converter Unit Mounting Dimensions

The dimensions and weights provided in the following drawings are for estimating purposes only. Contact your local Rockwell Automation Sales Office if certified drawings are required.

1336 REGEN Converter Unit - Frames B and C

Click to enlarge - 36r_b_dim
Dimensions are in millimeters and (inches)


1336 REGEN Converter Unit - Frame D

Click to enlarge - 36r_d_dim
Dimensions are in millimeters and (inches)


1336 REGEN Precharge Unit - Frames B and C

Click to enlarge - 36r_bpre_dim
Dimensions are in millimeters and (inches)


1336 REGEN Precharge Unit - Frame D

Click to enlarge - 36r_dpre_dim
Dimensions are in millimeters and (inches)