| d
|
| Enclosure
|
| Code
|
Enclosure
|
Conformal Coating
|
| A
|
IP20, NEMA/UL Type 1 §
|
No
|
| N
|
IP00, Open Chassis §
|
No
|
| § Frames 3A & 3B complete drive.
|
| § Frame 2 only.
|
| e
|
| HIM
|
| Code
|
Operator Interface
|
| 0
|
No HIM/Blank Cover
|
| 3
|
Full Numeric LCD (Frame 2 Only)
|
| C
|
Full Numeric LCD, Door Mount (Frames 3A & 3B Only)
|
| i
|
| Equipment Type
|
| Code
|
Description
|
Frame
|
| A
|
Complete Regenerative Drive
|
2, 3A & 3B
|
| j
|
| Comm Slot
|
| Code
|
Communication Option
|
DPI™ User Installed Kit Cat. No.
|
| N
|
None
|
N
|
| C
|
DPI ControlNet (Coax) ¬
|
20-Comm-C
|
| D
|
DPI DeviceNet ¬
|
20-Comm-D
|
| E
|
DPI EtherNet/IP ¬
|
20-Comm-E
|
| R
|
DPI RIO ¬
|
20-Comm-R
|
| S
|
DPI RS-485 DF1 ¬
|
20-Comm-S
|
| 1
|
DriveLogix™ ControlNet (Coax) T
|
-
|
| 2
|
DriveLogix ControlNet Redundant (Coax) T
|
-
|
| 3
|
DriveLogix ControlNet (Fiber) T
|
-
|
| 4
|
DriveLogix ControlNet Redundant (Fiber) T
|
-
|
| 5
|
DriveLogix DeviceNet (Open Conn.) T
|
-
|
| 6
|
DriveLogix EtherNet/IP T
|
-
|
| ¬ 700 Vector Control uses DPI comm. slot options only.
|
| T DriveLogix comm. slot options require 700S Phase II Control with DriveLogix5730.
|
| For 700S Phase II Control with DriveLogix5730, comm. slot option selections are mutually exclusive. For two communication adapters, (DPI and DriveLogix), select the DriveLogix comm. slot option and order the DPI user installed kit catalog number separately.
|
| k
|
| Control Options
|
| Code
|
Control
|
Cassette
|
Logic Expansion
|
Synch-Link
|
| 1
|
700VC 24V I/O
|
Base
|
N/A
|
N/A
|
| 2
|
700VC 120V I/O
|
Base
|
N/A
|
N/A
|
| A
|
700S Phase II
|
Expanded
|
No
|
No
|
| B
|
700S Phase II
|
Expanded
|
No
|
Yes
|
| C
|
700S Phase II
|
Expanded
|
Yes
|
No §
|
| D
|
700S Phase II
|
Expanded
|
Yes
|
Yes §
|
| § Requires DriveLogix5730.
|
| l
|
| Feedback
|
| Code
|
Control Option
|
Type
|
| 0
|
All
|
None
|
| 1
|
700VC
|
Encoder 5V/12V
|
| A
|
700S Ph. II
|
Resolver §
|
| B
|
700S Ph. II
|
Stegmann Hi-Resolution Encoder §
|
| C
|
700S Ph. II
|
Multi-Device Interface § Ø
|
| E
|
700S Ph. II
|
2nd Encoder §
|
| § Expanded cassette required.
|
| Ø Multi-Device Interface allows the connection of the Stegmann and Temposonics linear sensors. The Temposonics sensor cannot be used to close motor control or speed loops.
|
| m
|
| Additional Config.
|
| Code
|
Logix Option
|
Embedded Comm.
|
| W
|
None
|
-
|
| E
|
Phase II Control
|
No
|
| K
|
Phase II Control w/DriveLogix5730
|
No
|
| L
|
Phase II Control w/DriveLogix5730
|
EtherNet/IP
|
| 400V AC, Three-Phase Drives
|
| Output Amps
|
Nominal Power Ratings
|
IP20, NEMA/UL Type 1 ¬
|
Frame Size
|
| 400V AC Input
|
Normal Duty
|
Heavy Duty
|
Cat. No.
|
| Cont.
|
1 Min.
|
3 Sec.
|
kW
|
Hp
|
kW
|
Hp
|
| 360
|
396
|
540
|
200
|
268
|
150
|
200
|
20LC360N0ENNAN10WA
|
2
|
| 650
|
715
|
975
|
370
|
500
|
270
|
365
|
20LC650A0ENNAN10WA
|
3A
|
| 1250
|
1375
|
1875
|
715
|
960
|
525
|
700
|
20LC1K2A0ENNAN10WA
|
3B
|
|
|
| ¬ Frames 3A and 3B Only. Frame 2 drives are IP00, NEMA/UL Type Open.
|
| 480V AC, Three-Phase Drives
|
| Output Amps
|
Nominal Power Ratings
|
IP20, NEMA/UL Type 1 ¬
|
Frame Size
|
| 480V AC Input
|
Normal Duty
|
Heavy Duty
|
Cat. No.
|
| Cont.
|
1 Min.
|
3 Sec.
|
kW
|
Hp
|
kW
|
Hp
|
| 360
|
396
|
540
|
224
|
300
|
175
|
235
|
20LD360N0ENNAN10WA
|
2
|
| 650
|
715
|
975
|
445
|
600
|
325
|
440
|
20LD650A0ENNAN10WA
|
3A
|
| 1250
|
1375
|
1875
|
860
|
1150
|
630
|
845
|
20LD1K2A0ENNAN10WA
|
3B
|
|
|
| ¬ Frames 3A and 3B Only. Frame 2 drives are IP00, NEMA/UL Type Open.
|
| 600V AC, Three-Phase Drives
|
| Output Amps
|
Nominal Power Ratings
|
IP20, NEMA/UL Type 1
|
Frame Size
|
| 600V AC Input
|
Normal Duty
|
Heavy Duty
|
Cat. No.
|
| Cont.
|
1 Min.
|
3 Sec.
|
kW
|
Hp
|
kW
|
Hp
|
| 425
|
470
|
640
|
345
|
465
|
255
|
345
|
20LE425A0ENNAN10WA
|
3A
|
| 800
|
885
|
1200
|
650
|
870
|
480
|
640
|
20LE800A0ENNAN10WA
|
3B
|
|
|
| 690V AC, Three-Phase Drives
|
| Output Amps
|
Nominal Power Ratings
|
IP20, NEMA/UL Type 1
|
Frame Size
|
| 690V AC Input
|
Normal Duty
|
Heavy Duty
|
Cat. No.
|
| Cont.
|
1 Min.
|
3 Sec.
|
kW
|
Hp
|
kW
|
Hp
|
| 380
|
420
|
570
|
355
|
475
|
260
|
350
|
20LF380A0ENNAN10WA
|
3A
|
| 705
|
780
|
1060
|
657
|
881
|
485
|
650
|
20LF705A0ENNAN10WA
|
3B
|
|
|
| Documentation
|
| Description
|
Cat. Code
|
| (Position f)
|
| English Documentation Set
|
E
|
| No Documentation
|
N
|
|
|
| Internal Communication Adapters
|
| Description
|
Cat. Code
|
| (Position j)
|
| None
|
N
|
| ControlNet™ Communication Adapter (Coax)
|
C
|
| DeviceNet™ Communication Adapter
|
D
|
| EtherNet/IP™ Communication Adapter
|
E
|
| Remote I/O Communication Adapter
|
R
|
| RS485 DF1 Communication Adapter
|
S
|
| DriveLogix Comm Option, ControlNet (Coax) §
|
1
|
| DriveLogix Comm Option, ControlNet Redundant (Coax) §
|
2
|
| DriveLogix Comm Option, ControlNet (Fiber) §
|
3
|
| DriveLogix Comm Option, ControlNet Redundant (Fiber) §
|
4
|
| DriveLogix Comm Option, DeviceNet (Open Conn.) §
|
5
|
| DriveLogix Comm Option, EtherNet/IP (Twisted Pair) §
|
6
|
|
|
| 700 Vector Control uses DPI comm. slot options only.
|
| § DriveLogix comm. slot option requires 700S Phase II Control with DriveLogix5730.
|
| Control Options
|
| Control Option
|
Description
|
Cat. Code
|
| (Position k)
|
| 700VC - 24V I/O
|
Base Cassette
|
1
|
| 700VC - 115V I/O
|
Base Cassette
|
2
|
| Phase II Control
|
Expanded Cassette Only
|
A
|
| Expanded Cassette w/SynchLink
|
B
|
| Phase II Control ¬
|
Expanded Cassette w/Logix Expansion Board
|
C
|
| Expanded Cassette w/Logix Expansion Board & SynchLink
|
D
|
|
|
| ¬ Requires DriveLogix5730.
|
| Feedback Options
|
| Control Type
|
Description
|
Cat. Code
|
| (Position l)
|
| All
|
No Encoder
|
0
|
| 700VC
|
12V/5V Encoder
|
1
|
| 700S Phase II
|
Resolver, 10…26V, 10 kHz, 10…16 bit
|
A
|
| Stegmann - High Resolution Encoder Hyperface, 8.5V DC, 20 bit, 100k/r §
|
B
|
| Multi-Device Interface - for Stegmann or Linear Temposonics §
|
C
|
| 2nd Encoder, 5V or 12V Configurable by the Drive §
|
E
|
| DriveGuard Safe-Off (w/2nd Encoder) §
|
S
|
|
|
| § Requires Expanded Cassette.
|
| Additional 700S Configurations
|
| Description
|
Embedded Communication
|
Cat. Code
|
| (Position m)
|
| None
|
—
|
W
|
| Phase II Control
|
No
|
E
|
| Phase II Control, with DriveLogix5730 Controller
|
No
|
K
|
| Phase II Control, with DriveLogix5730 Controller & EtherNet/IP
|
EtherNet/IP
|
L
|
|
|
| Human Interface and Wireless Interface Modules
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
No HIM (Blank Plate) 20-HIM-A0
|
|
LCD Display, Full Numeric Keypad 20-HIM-A3
|
|
LCD Display, Programmer Only 20-HIM-A5
|
|
Wireless Interface Module 20-WIM-N1
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Remote (Panel Mount) LCD Display, Full Numeric Keypad 20-HIM-C3S
|
|
Remote (Panel Mount) LCD Display, Programmer Only 20-HIM-C5S
|
|
Remote (Panel Mount) Wireless Interface Module 20-WIM-N4S
|
|
|
| Description
|
Handheld/Local (Drive Mount)
|
Remote (Panel Mount) IP66, NEMA/UL Type 4x/12 ¬
|
| Cat. No.
|
Cat. No.
|
| No HIM (Blank Plate)
|
20-HIM-A0
|
|
| LCD Display, Full Numeric Keypad
|
20-HIM-A3
|
20-HIM-C3S §
|
| LCD Display, Programmer Only
|
20-HIM-A5
|
20-HIM-C5S §
|
| Wireless Interface Module
|
20-WIM-N1
|
20-WIM-N4S
|
|
|
| ¬ For indoor use only.
|
| § Includes a 1202-C30 interface cable (3 meters) for connection to drive.
|
| Human Interface Module Accessories
|
| Description
|
Cat. No.
|
| Bezel Kit for LCD HIMs, NEMA/UL Type 1 §
|
20-HIM-B1
|
| PowerFlex HIM Interface Cable, 1 m (39 in) §
|
20-HIM-H10
|
| Cable Kit (Male-Female) Ø
|
| 0.33 Meters (1.1 Feet)
|
1202-H03
|
| 1 Meter (3.3 Feet)
|
1202-H10
|
| 3 Meter (9.8 Feet)
|
1202-H30
|
| 9 Meter (29.5 Feet)
|
1202-H90
|
| DPI/SCANport™ One to Two Port Splitter Cable
|
1203-S03
|
|
|
| § Includes a 1202-C30 interface cable (3 meters) for connection to drive.
|
| § Required only when HIM is used as handheld or remote.
|
| Ø Required in addition to 20-HIM-H10 for distances up to a total maximum of 10 Meters (32.8 Feet).
|
| Communication Option Kits
|
| Description
|
Cat. No.
|
| ControlNet™ Communication Adapter (Coax)
|
20-COMM-C
|
| DeviceNet™ Communication Adapter
|
20-COMM-D
|
| EtherNet/IP™ Communication Adapter
|
20-COMM-E
|
| Interbus™ Communication Adapter
|
20-COMM-I
|
| CANopen® Communication Adapter
|
20-COMM-K
|
| Modbus/TCP Communication Adapter
|
20-COMM-M
|
| PROFIBUS™ DP Communication Adapter
|
20-COMM-P
|
| ControlNet™ Communication Adapter (Fiber)
|
20-COMM-Q
|
| Remote I/O Communication Adapter
|
20-COMM-R
|
| RS485 DF1 Communication Adapter
|
20-COMM-S
|
| DriveLogix ControlNet Communication Adapter (Coax) ¬ v
|
1788-CNC
|
| DriveLogix Comm Option, ControlNet Redundant (Coax) ¬ v
|
1788-CNCR
|
| DriveLogix Comm Option, ControlNet (Fiber) ¬ v
|
1788-CNF
|
| DriveLogix Comm Option, ControlNet Redundant (Fiber) ¬ v
|
1788-CNFR
|
| DriveLogix Comm Option, DeviceNet (Open Conn.) ¬ v
|
1788-DNBO
|
| DriveLogix Comm Option, EtherNet/IP (Twisted Pair) ¬ v
|
1788-ENBT
|
| DriveLogix5730 Comm Option, Embedded EtherNet/IP
|
20D-DL2-ENET0
|
| External Communications Kit Power Supply
|
20-XCOMM-AC-PS1
|
| DPI External Communications Kit
|
20-XCOMM-DC-BASE
|
| External DPI I/O Option Board ª
|
20-XCOMM-IO-OPT1
|
| Compact I/O Module (3 Channel)
|
1769-SM1
|
|
|
| ¬ For use with DriveLogix option only.
|
| ª For use only with External DPI Communications Kits 20-XCOMM-DC-BASE.
|
| v Requires Logix Expansion Board (20D-DL2-LEB0).
|
| Communication Accessories
|
| Description
|
Cat. No.
|
| Serial Null Modem Adapter
|
1203-SNM
|
| Smart Self-powered Serial Converter (RS232) includes 1203-SFC and 1202-C10 Cables
|
1203-SSS
|
| Universal Serial Bus™ (USB) Converter includes 2m USB, 20-HIM-H10 & 22-HIM-H10 Cables
|
1203-USB
|
| ControlNet Ex Right-Angle T-Tap 1 Meter Coax Cable Assembly
|
1786-TPR
|
|
|
| Description
|
Cat. No.
|
| SynchLink Board
|
20D-P2-SLB0
|
| SynchLink Fiber Base Block
|
1751-SLBA
|
| SynchLink 4-port Fiber Splitter Block
|
1751-SL4SP
|
| SynchLink Fiber Bypass Switch Block
|
1751-SLBP
|
| 2x1 Meter Fiber Link for Power Monitor/SynchLink
|
1403-CF001
|
| 2x3 Meter Fiber Link for Power Monitor/SynchLink
|
1403-CF003
|
| 2x5 Meter Fiber Link for Power Monitor/SynchLink
|
1403-CF005
|
| 10 Meter Fiber Link for Power Monitor/SynchLink
|
1403-CF010
|
| 20 Meter Fiber Link for Power Monitor/SynchLink
|
1403-CF020
|
| 50 Meter Fiber Link for Power Monitor/SynchLink
|
1403-CF050
|
| 100 Meter Fiber Link for Power Monitor/SynchLink
|
1403-CF100
|
| 250 Meter Fiber Link for Power Monitor/SynchLink
|
1403-CF250
|
|
|
| PC Programming Software
|
| Description
|
| DriveTools™ SP Software ª
|
| DriveExplorer™ Software (Lite/Full) ª v
|
|
|
| ª Set-up wizards are available for use with DriveTools SP and DriveExplorer (Lite/Full) only.
|
| v DriveExplorer Lite is available for free download at: http://www.ab.com/drives/driveexplorer/free_download.html.
|
| Feedback Option Kits
|
| Description
|
Cat. No.
|
| Multi-Device Interface Ø
|
20D-MDI-C2
|
| DriveGuard Safe-Off (w/2nd Encoder) Ø
|
20D-P2-DG01
|
| 2nd Encoder, 5V/12V Ø
|
20D-P2-ENC0
|
| Resolver Ø
|
20D-RES-A1
|
| Stegmann High Resolution Hyperface Encoder Ø
|
20D-STEG-B1
|
|
|
| Ø Requires Expanded Cassette.
|
| DriveLogix Option Kits
|
| Description
|
Cat. No.
|
| Logix Expansion board for DriveLogix5730 Ø
|
20D-DL2-LEB0
|
| Industrial Compact Flash 64 MB Memory Card for DriveLogix5730
|
1784-CF64
|
|
|
| Ø Requires Expanded Cassette.
|
| DriveLogix I/O Cables
|
| Description
|
Cat. No.
|
| DriveLogix5730 - Compact I/O cable, 3.28 ft. (1 meter), Left Bus CapØ §
|
20D-DL2-CL3
|
| DriveLogix5730 - Compact I/O cable, 3.28 ft. (1 meter), Right Bus Cap Ø §
|
20D-DL2-CR3
|
| Logix5000 RS-232 Programming Cable
|
1756-CP3
|
|
|
| Ø Requires Expanded Cassette.
|
| § Refer to Publication 1769-SG001 for details and selection of Compact I/O.
|
| Cooling Loops
|
| Drive Requirements
|
Supply Loop Requirements
|
Liquid to Liquid Heat Exchanger T
|
| Frame Size
|
Heat Dissipation into Liquid
|
Minimum Flow @ Pressure ¬
|
Maximum Pressure
|
Temperature Range
|
Cat. No.
|
| 2
|
7,900 W
|
15.1 LPM @ 0.83 bar (4 GPM @ 12 PSI)
|
8.62 bar (125 PSI)
|
0…40° C (32…104° F)
|
20L-LL13K-P75A
|
| 3A
|
12,000 W
|
22.7 LPM @ 0.83 bar (6 GPM @ 12 PSI)
|
8.62 bar (125 PSI)
|
0…35° C (32…95° F)
|
20L-LL13K-P75A
|
| 3B
|
24,000 W
|
56.8 LPM @ 0.83 bar (15 GPM @ 12 PSI)
|
8.62 bar (125 PSI)
|
0…35° C (32…95° F)
|
20L-LL24K-1P0A
|
|
|
| ¬ The minimum pressure applies to the pressure drop across the drive and does not take into account additional pressure drop in the system such as piping or hosing.
|
| T Recommended cooling loops shown are based on a single drive per cooling loop. Consult the factory for use of multiple drives on one cooling loop.
|
| Hose Kits
|
Hose Length m (ft.)
|
Hoses per Kit
|
Drive Side Coupling Size
|
Heat Exchanger Side Coupling Size
|
Used with …
|
Hose Kit Cat. No.
|
| 3 (10)
|
2
|
0.75 in.
|
0.75 in.
|
Frame 2 and 13 kW HEX
|
20L-GH10-B1
|
| 9.1 (30)
|
2
|
0.75 in.
|
0.75 in.
|
Frame 2 and 13 kW HEX
|
20L-GH30-B1
|
| 3 (10)
|
2
|
1 in.
|
1 in. with 90° Elbow
|
Frame 3A and 13 kW HEX
|
20L-GH10-A2
|
| 9.1 (30)
|
2
|
1 in.
|
1 in. with 90° Elbow
|
Frame 3A and 13 kW HEX
|
20L-GH30-A2
|
| 3 (10)
|
2
|
1 in.
|
1 in.
|
Frame 3B and 24 kW HEX
|
20L-GH10-A1
|
| 9.1 (30)
|
2
|
1 in.
|
1 in.
|
Frame 3B and 24 kW HEX
|
20L-GH30-A1
|
|
|
| ¬ Each Hose Kit contains (2) hoses and the appropriate connectors.
|
| Application Module ¬
|
Cat. No.
|
Phone Support
|
| Center Winder/Unwind §
|
9329-KAA12A
|
T
|
| Inline Tensioning §
|
9329-KAA12B
|
T
|
| Lead Line Control
|
9329-KAA12C
|
T
|
| Positioning (Point to Point)
|
9329-KAA11D
|
T
|
| Process Line Suite §
|
9329-KAA12E
|
T
|
| Function Modules
|
| Spindle Orient
|
|
None
|
| Torque Prove
|
|
None
|
|
|
| ¬ DriveLogix is required for use with the Drive Application Software — Application Modules.
|
| T Phone support is application related technical phone support and is in addition to standard drives support included with hardware purchases. Contact Technical Support for ordering details and phone support hours.
|
| Restricted Access, Contact Technical Support to place order.
|
| § These programs are available to OEMs and System Integrators with in-house services capable of on-site commissioning, complete support and service of the applications.
|