PowerFlex 700L

Product Overview


Click to enlarge - 700L_Front
PowerFlex 700L Complete Drive (Frame 3B shown)


PowerFlex 700/700S Control, Liquid-Cooled Power Structure

Exceptional Performance in a Space-Saving Design

Regenerative Liquid-Cooled PowerFlex drives utilize integrated active converter technology and also offer improved power quality over a wide range of industrial power voltages.

Integrated Line Regenerative Braking for Precise Control and Energy Savings

The Liquid-Cooled AC drive features regenerative braking which is ideal for precise, high-response speed and position control, continuous holdback, rapid deceleration and stopping of high inertia loads. Instead of wasting energy with resistor braking technology, regenerative braking actually puts the energy back into the system to be used by other equipment.

Improved Power Quality with Regenerative Rectifier


Increased Power Density

The PowerFlex Liquid-Cooled AC drive features a patented liquid-cooled heatsink design to transfer over 80% of the drive heat loss to the liquid coolant, resulting in the best drive power-to-size ratio in the market. The integral active converter and line filter translate to a fully regenerative drive that's over 60% smaller than typical air-cooled units.

Protect your System From Power Disturbances

Integrated active converter and line-side filter allow "input voltage boost."


Conformity to Standards

The PowerFlex® 700L drive conforms to the following:

Conformity to: Standard Product
UL Listed ü
CSA Certified (c-UL) ü
IEC (Designed to Meet) ü
CE Approved ü
  

Drive Description

PowerFlex 700L Liquid-Cooled AC drives are responsive, high performance, regenerative industrial motor drives for applications requiring compact non-ventilated enclosures. The PowerFlex 700L drive offers two versions of control: either the PowerFlex 700 Vector Control or the PowerFlex 700S Phase II Control. This provides the PowerFlex 700L drive with exceptional and proven performance as well as the same interface, communications capabilities and programming tools of the air-cooled drives. The many features allow the user to easily configure the drive for most application needs. Ratings currently available include:


An LCD Human Interface Module (also used with the PowerFlex 70, 700, 700S, and 700H) provides multilingual text for startup, metering, programming, and troubleshooting.

PowerFlex 700L drives are configurable for Volts-per-Hertz, Sensorless Vector and Vector Control with Force Technology™ to meet a wide variety of application needs. This control is housed in a separately removable cassette which is the same for all drive ratings, simplifying installation and maintenance for the entire product line.

Optional internal communication modules provide fast and efficient control and/or data exchange over the following interfaces:



Catalog Number Explanation

20L    E    800    A    0    E    N    N    A    N    1    0    W    A
a    b    c    d    e    f    g    h    i    j    k    l    m    n

a
Drive
Code Type
20L PowerFlex 700L

b
Voltage Rating
Code Voltage Ph.
C 400V AC 3
D 480V AC 3
E 600V AC 3
F 690V AC 3

c1
ND Rating
400V, 60 Hz Input
Code Amps kW Hp Frame
360 360 200 268 2
650 650 370 500 3A
1K2 1250 715 960 3B

c2
ND Rating
480V, 60 Hz Input
Code Amps kW Hp Frame
360 360 224 300 2
650 650 445 600 3A
1K2 1250 860 1150 3B

c3
ND Rating
600V, 60 Hz Input
Code Amps kW Hp Frame
425 425 345 465 3A
800 800 650 870 3B

c4
ND Rating
690V, 60 Hz Input
Code Amps kW Hp Frame
380 380 355 475 3A
705 705 657 881 3B

d
Enclosure
Code Enclosure Conformal Coating
A IP20, NEMA/UL Type 1 §  No
N IP00, Open Chassis §  No
§ Frames 3A & 3B complete drive.
§ Frame 2 only.

e
HIM
Code Operator Interface
0 No HIM/Blank Cover
3 Full Numeric LCD (Frame 2 Only)
C Full Numeric LCD, Door Mount (Frames 3A & 3B Only)

f
Documentation
Code Documents Ship Carton
E English Doc Set Yes
N No Documentation Yes

g
Brake
Code w/Brake IGBT
N No

h
Brake Resistor
Code w/Resistor
N No

i
Equipment Type
Code Description Frame
A Complete Regenerative Drive 2, 3A & 3B

j
Comm Slot
Code Communication Option DPI™ User Installed Kit Cat. No. ‡ 
N None N
C DPI ControlNet (Coax) ¬  20-Comm-C
D DPI DeviceNet ¬  20-Comm-D
E DPI EtherNet/IP ¬  20-Comm-E
R DPI RIO ¬  20-Comm-R
S DPI RS-485 DF1 ¬  20-Comm-S
1 DriveLogix™ ControlNet (Coax) T  -
2 DriveLogix ControlNet Redundant (Coax) T  -
3 DriveLogix ControlNet (Fiber) T  -
4 DriveLogix ControlNet Redundant (Fiber) T  -
5 DriveLogix DeviceNet (Open Conn.) T  -
6 DriveLogix EtherNet/IP T  -
¬ 700 Vector Control uses DPI comm. slot options only.
T DriveLogix comm. slot options require 700S Phase II Control with DriveLogix5730.
‡ For 700S Phase II Control with DriveLogix5730, comm. slot option selections are mutually exclusive. For two communication adapters, (DPI and DriveLogix), select the DriveLogix comm. slot option and order the DPI user installed kit catalog number separately.

k
Control Options
Code Control Cassette Logic Expansion Synch-Link
1 700VC 24V I/O Base N/A N/A
2 700VC 120V I/O Base N/A N/A
A 700S Phase II Expanded No No
B 700S Phase II Expanded No Yes
C 700S Phase II Expanded Yes No § 
D 700S Phase II Expanded Yes Yes § 
§ Requires DriveLogix5730.

l
Feedback
Code Control Option Type
0 All None
1 700VC Encoder 5V/12V
A 700S Ph. II Resolver § 
B 700S Ph. II Stegmann Hi-Resolution Encoder § 
C 700S Ph. II Multi-Device Interface § Ø 
E 700S Ph. II 2nd Encoder § 
§ Expanded cassette required.
Ø Multi-Device Interface allows the connection of the Stegmann and Temposonics linear sensors. The Temposonics sensor cannot be used to close motor control or speed loops.

m
Additional Config.
Code Logix Option Embedded Comm.
W None -
E Phase II Control No
K Phase II Control w/DriveLogix5730 No
L Phase II Control w/DriveLogix5730 EtherNet/IP

n
Coolant Type
Code Coolant Frame
A Water All

Product Selection

Build a Catalog Number


400V AC, Three-Phase Drives
Output Amps Nominal Power Ratings IP20, NEMA/UL Type 1 ¬  Frame Size
400V AC Input Normal Duty Heavy Duty Cat. No.
Cont. 1 Min. 3 Sec. kW Hp kW Hp
360 396 540 200 268 150 200 20LC360N0ENNAN10WA 2
650 715 975 370 500 270 365 20LC650A0ENNAN10WA 3A
1250 1375 1875 715 960 525 700 20LC1K2A0ENNAN10WA 3B
  
¬ Frames 3A and 3B Only. Frame 2 drives are IP00, NEMA/UL Type Open.

480V AC, Three-Phase Drives
Output Amps Nominal Power Ratings IP20, NEMA/UL Type 1 ¬  Frame Size
480V AC Input Normal Duty Heavy Duty Cat. No.
Cont. 1 Min. 3 Sec. kW Hp kW Hp
360 396 540 224 300 175 235 20LD360N0ENNAN10WA 2
650 715 975 445 600 325 440 20LD650A0ENNAN10WA 3A
1250 1375 1875 860 1150 630 845 20LD1K2A0ENNAN10WA 3B
  
¬ Frames 3A and 3B Only. Frame 2 drives are IP00, NEMA/UL Type Open.

600V AC, Three-Phase Drives
Output Amps Nominal Power Ratings IP20, NEMA/UL Type 1 Frame Size
600V AC Input Normal Duty Heavy Duty Cat. No.
Cont. 1 Min. 3 Sec. kW Hp kW Hp
425 470 640 345 465 255 345 20LE425A0ENNAN10WA 3A
800 885 1200 650 870 480 640 20LE800A0ENNAN10WA 3B
  

690V AC, Three-Phase Drives
Output Amps Nominal Power Ratings IP20, NEMA/UL Type 1 Frame Size
690V AC Input Normal Duty Heavy Duty Cat. No.
Cont. 1 Min. 3 Sec. kW Hp kW Hp
380 420 570 355 475 260 350 20LF380A0ENNAN10WA 3A
705 780 1060 657 881 485 650 20LF705A0ENNAN10WA 3B
  

Factory Installed Options

Human Interface and Wireless Interface Modules
IP20, NEMA/UL Type 1 (Position e)
Click to enlarge - 20him_blank Click to enlarge - 20him_a3 Click to enlarge - himbezel_c
     
Cat. Code: 0
No HIM (Blank Plate)
Cat. Code: 3
LCD Display, Full Numeric Keypad
Cat. Code: C
Door Mounted Bezel LCD Display, Full Numeric Keypad
NEMA/UL Type 1

Documentation
Description Cat. Code
(Position f)
English Documentation Set E
No Documentation N
  

Internal Communication Adapters
Description Cat. Code
(Position j)
None N
ControlNet™ Communication Adapter (Coax) ‡  C
DeviceNet™ Communication Adapter ‡  D
EtherNet/IP™ Communication Adapter ‡  E
Remote I/O Communication Adapter ‡  R
RS485 DF1 Communication Adapter ‡  S
DriveLogix Comm Option, ControlNet (Coax) §  1
DriveLogix Comm Option, ControlNet Redundant (Coax) §  2
DriveLogix Comm Option, ControlNet (Fiber) §  3
DriveLogix Comm Option, ControlNet Redundant (Fiber) §  4
DriveLogix Comm Option, DeviceNet (Open Conn.) §  5
DriveLogix Comm Option, EtherNet/IP (Twisted Pair) §  6
  
‡ 700 Vector Control uses DPI comm. slot options only.
§ DriveLogix comm. slot option requires 700S Phase II Control with DriveLogix5730.

Control Options
Control Option Description Cat. Code
(Position k)
700VC - 24V I/O Base Cassette 1
700VC - 115V I/O Base Cassette 2
Phase II Control Expanded Cassette Only A
Expanded Cassette w/SynchLink B
Phase II Control ¬  Expanded Cassette w/Logix Expansion Board C
Expanded Cassette w/Logix Expansion Board & SynchLink D
 
¬ Requires DriveLogix5730.

Feedback Options
Control Type Description Cat. Code
(Position l)
All No Encoder 0
700VC 12V/5V Encoder 1
700S Phase II Resolver, 10…26V, 10 kHz, 10…16 bit A
Stegmann - High Resolution Encoder Hyperface, 8.5V DC, 20 bit, 100k/r §  B
Multi-Device Interface - for Stegmann or Linear Temposonics §  C
2nd Encoder, 5V or 12V Configurable by the Drive §  E
DriveGuard Safe-Off (w/2nd Encoder) §  S
 
§ Requires Expanded Cassette.

Additional 700S Configurations
Description Embedded Communication Cat. Code
(Position m)
None W
Phase II Control No E
Phase II Control, with DriveLogix5730 Controller No K
Phase II Control, with DriveLogix5730 Controller & EtherNet/IP EtherNet/IP L
  

Coolant Options
Description Frame Cat. Code
(Position n)
Reclaimed Water All A
  

User Installed Options

Human Interface and Wireless Interface Modules
Click to enlarge - 20him_blank   Click to enlarge - 20him_a3   Click to enlarge - 20him_a5   Click to enlarge - 20wim_n1
             
No HIM (Blank Plate)
20-HIM-A0
  LCD Display, Full Numeric Keypad
20-HIM-A3
  LCD Display, Programmer Only
20-HIM-A5
  Wireless Interface Module
20-WIM-N1
             
Click to enlarge - 20him_c3s   Click to enlarge - 20him_c5s   Click to enlarge - 20wim_4ns    
             
Remote (Panel Mount) LCD Display, Full Numeric Keypad
20-HIM-C3S
  Remote (Panel Mount) LCD Display, Programmer Only
20-HIM-C5S
  Remote (Panel Mount)
Wireless Interface Module
20-WIM-N4S
   

Description Handheld/Local (Drive Mount) Remote (Panel Mount) IP66, NEMA/UL Type 4x/12 ¬ 
Cat. No. Cat. No.
No HIM (Blank Plate) 20-HIM-A0
LCD Display, Full Numeric Keypad 20-HIM-A3 20-HIM-C3S § 
LCD Display, Programmer Only 20-HIM-A5 20-HIM-C5S § 
Wireless Interface Module 20-WIM-N1 20-WIM-N4S
  
¬ For indoor use only.
§ Includes a 1202-C30 interface cable (3 meters) for connection to drive.

Human Interface Module Accessories
Description Cat. No.
Bezel Kit for LCD HIMs, NEMA/UL Type 1 §  20-HIM-B1
PowerFlex HIM Interface Cable, 1 m (39 in) §  20-HIM-H10
Cable Kit (Male-Female) Ø 
0.33 Meters (1.1 Feet)
1202-H03
1 Meter (3.3 Feet)
1202-H10
3 Meter (9.8 Feet)
1202-H30
9 Meter (29.5 Feet)
1202-H90
DPI/SCANport™ One to Two Port Splitter Cable 1203-S03
  
§ Includes a 1202-C30 interface cable (3 meters) for connection to drive.
§ Required only when HIM is used as handheld or remote.
Ø Required in addition to 20-HIM-H10 for distances up to a total maximum of 10 Meters (32.8 Feet).

Communication Option Kits
Description Cat. No.
ControlNet™ Communication Adapter (Coax) 20-COMM-C
DeviceNet™ Communication Adapter 20-COMM-D
EtherNet/IP™ Communication Adapter 20-COMM-E
Interbus™ Communication Adapter 20-COMM-I
CANopen® Communication Adapter 20-COMM-K
Modbus/TCP Communication Adapter 20-COMM-M
PROFIBUS™ DP Communication Adapter 20-COMM-P
ControlNet™ Communication Adapter (Fiber) 20-COMM-Q
Remote I/O Communication Adapter 20-COMM-R
RS485 DF1 Communication Adapter 20-COMM-S
DriveLogix ControlNet Communication Adapter (Coax) ¬ v  1788-CNC
DriveLogix Comm Option, ControlNet Redundant (Coax) ¬ v  1788-CNCR
DriveLogix Comm Option, ControlNet (Fiber) ¬ v  1788-CNF
DriveLogix Comm Option, ControlNet Redundant (Fiber) ¬ v  1788-CNFR
DriveLogix Comm Option, DeviceNet (Open Conn.) ¬ v  1788-DNBO
DriveLogix Comm Option, EtherNet/IP (Twisted Pair) ¬ v  1788-ENBT
DriveLogix5730 Comm Option, Embedded EtherNet/IP 20D-DL2-ENET0
External Communications Kit Power Supply 20-XCOMM-AC-PS1
DPI External Communications Kit 20-XCOMM-DC-BASE
External DPI I/O Option Board ª  20-XCOMM-IO-OPT1
Compact I/O Module (3 Channel) 1769-SM1
  
¬ For use with DriveLogix option only.
ª For use only with External DPI Communications Kits 20-XCOMM-DC-BASE.
v Requires Logix Expansion Board (20D-DL2-LEB0).

Communication Accessories
Description Cat. No.
Serial Null Modem Adapter 1203-SNM
Smart Self-powered Serial Converter (RS232) includes 1203-SFC and 1202-C10 Cables 1203-SSS
Universal Serial Bus™ (USB) Converter includes 2m USB, 20-HIM-H10 & 22-HIM-H10 Cables 1203-USB
ControlNet Ex Right-Angle T-Tap 1 Meter Coax Cable Assembly 1786-TPR
  

Accessories

Note: Please refer to publication number 1756-TD008 for details on SynchLink.

Description Cat. No.
SynchLink Board 20D-P2-SLB0
SynchLink Fiber Base Block 1751-SLBA
SynchLink 4-port Fiber Splitter Block 1751-SL4SP
SynchLink Fiber Bypass Switch Block 1751-SLBP
2x1 Meter Fiber Link for Power Monitor/SynchLink 1403-CF001
2x3 Meter Fiber Link for Power Monitor/SynchLink 1403-CF003
2x5 Meter Fiber Link for Power Monitor/SynchLink 1403-CF005
10 Meter Fiber Link for Power Monitor/SynchLink 1403-CF010
20 Meter Fiber Link for Power Monitor/SynchLink 1403-CF020
50 Meter Fiber Link for Power Monitor/SynchLink 1403-CF050
100 Meter Fiber Link for Power Monitor/SynchLink 1403-CF100
250 Meter Fiber Link for Power Monitor/SynchLink 1403-CF250
  

PC Programming Software
Description
DriveTools™ SP Software ª 
DriveExplorer™ Software (Lite/Full) ª v 
 
ª Set-up wizards are available for use with DriveTools SP and DriveExplorer (Lite/Full) only.
v DriveExplorer Lite is available for free download at: http://www.ab.com/drives/driveexplorer/free_download.html.

Feedback Option Kits
Description Cat. No.
Multi-Device Interface Ø  20D-MDI-C2
DriveGuard Safe-Off (w/2nd Encoder) Ø  20D-P2-DG01
2nd Encoder, 5V/12V Ø  20D-P2-ENC0
Resolver Ø  20D-RES-A1
Stegmann High Resolution Hyperface Encoder Ø  20D-STEG-B1
  
Ø Requires Expanded Cassette.

DriveLogix Option Kits
Description Cat. No.
Logix Expansion board for DriveLogix5730 Ø  20D-DL2-LEB0
Industrial Compact Flash 64 MB Memory Card for DriveLogix5730 1784-CF64
  
Ø Requires Expanded Cassette.

DriveLogix I/O Cables
Description Cat. No.
DriveLogix5730 - Compact I/O cable, 3.28 ft. (1 meter), Left Bus CapØ §  20D-DL2-CL3
DriveLogix5730 - Compact I/O cable, 3.28 ft. (1 meter), Right Bus Cap Ø §  20D-DL2-CR3
Logix5000 RS-232 Programming Cable 1756-CP3
  
Ø Requires Expanded Cassette.
§ Refer to Publication 1769-SG001 for details and selection of Compact I/O.

Cooling Loops

The various types of cooling Loops are explained below.

Liquid to Liquid Heat Exchanger

The liquid to liquid heat exchanger utilizes a heat transfer plate to transfer heat from one liquid to another. This method requires a stable water supply from the user.

Click to enlarge - cooling_1


Liquid to Air Heat Exchanger

The liquid to air heat exchanger utilizes radiator technology to transfer heat from a liquid to surrounding air. This is a simple closed loop system - it does not require a water supply from the user. However, this system requires surrounding air 5 to 10°C below the maximum operating temperature of the drive.

Click to enlarge - cooling_2


Chiller

The chiller utilizes refrigerant to transfer heat from a liquid to air. This is a simple closed loop system – it does not require a water supply from the user. A chiller can achieve almost any water temperature required.

Click to enlarge - cooling_3


Cooling Loops
Drive Requirements Supply Loop Requirements Liquid to Liquid Heat Exchanger T 
Frame Size Heat Dissipation into Liquid Minimum Flow @ Pressure ¬  Maximum Pressure Temperature Range Cat. No.
2 7,900 W 15.1 LPM @ 0.83 bar (4 GPM @ 12 PSI) 8.62 bar (125 PSI) 0…40° C (32…104° F) 20L-LL13K-P75A
3A 12,000 W 22.7 LPM @ 0.83 bar (6 GPM @ 12 PSI) 8.62 bar (125 PSI) 0…35° C (32…95° F) 20L-LL13K-P75A
3B 24,000 W 56.8 LPM @ 0.83 bar (15 GPM @ 12 PSI) 8.62 bar (125 PSI) 0…35° C (32…95° F) 20L-LL24K-1P0A
  
¬ The minimum pressure applies to the pressure drop across the drive and does not take into account additional pressure drop in the system such as piping or hosing.
T Recommended cooling loops shown are based on a single drive per cooling loop. Consult the factory for use of multiple drives on one cooling loop.

Hose Kits
Hose Length
m (ft.)
Hoses per Kit Drive Side Coupling Size Heat Exchanger Side Coupling Size Used with … Hose Kit Cat. No.
3 (10) 2 0.75 in. 0.75 in. Frame 2 and 13 kW HEX 20L-GH10-B1
9.1 (30) 2 0.75 in. 0.75 in. Frame 2 and 13 kW HEX 20L-GH30-B1
3 (10) 2 1 in. 1 in. with 90° Elbow Frame 3A and 13 kW HEX 20L-GH10-A2
9.1 (30) 2 1 in. 1 in. with 90° Elbow Frame 3A and 13 kW HEX 20L-GH30-A2
3 (10) 2 1 in. 1 in. Frame 3B and 24 kW HEX 20L-GH10-A1
9.1 (30) 2 1 in. 1 in. Frame 3B and 24 kW HEX 20L-GH30-A1
  
¬ Each Hose Kit contains (2) hoses and the appropriate connectors.

Drive Application Software

Click to enlarge - 9329_AppSoftware_icon


Drive Application Software brings together an outstanding range of application experience and performance drive products to provide the user with pre-engineered and cost effective drive application solutions.

The following Application Modules are available for installation and use exclusively in the PowerFlex 700S AC drives with DriveLogix® that are provided to customers. The Drive Application Software is licensed and cannot be transferred or resold. On site commissioning and support services are not included with Drive Application Software.



Product Selection

Application Module ¬  Cat. No. Phone Support
Center Winder/Unwind ‡ §  9329-KAA12A T 
Inline Tensioning ‡ §  9329-KAA12B T 
Lead Line Control ‡  9329-KAA12C T 
Positioning (Point to Point) ‡  9329-KAA11D T 
Process Line Suite ‡ §  9329-KAA12E T 
Function Modules
Spindle Orient ‡ 
  None
Torque Prove ‡ 
  None
 
¬ DriveLogix is required for use with the Drive Application Software — Application Modules.
T Phone support is application related technical phone support and is in addition to standard drives support included with hardware purchases. Contact Technical Support for ordering details and phone support hours.
‡ Restricted Access, Contact Technical Support to place order.
§ These programs are available to OEMs and System Integrators with in-house services capable of on-site commissioning, complete support and service of the applications.

Media