Drives Catalog

Catalogs > Drives Catalog > PowerFlex 700L

PowerFlex 700L

Introduction Conformity to Standards Drive Description Catalog Number Explanation
Product Selection Factory Installed Options User Installed Options Drive Application Software
Catalog Number Explanation

20L    E    800    A    0    E    N    N    A    N    1    0    W    A
a    b    c    d    e    f    g    h    i    j    k    l    m    n

a
Drive
Code Type
20L PowerFlex 700L

b
Voltage Rating
Code Voltage Ph.
C 400V AC 3
D 480V AC 3
E 600V AC 3
F 690V AC 3

c1
ND Rating
400V, 60 Hz Input
Code Amps kW Hp Frame
360 360 200 268 2
650 650 370 500 3A
1K2 1250 715 960 3B

c2
ND Rating
480V, 60 Hz Input
Code Amps kW Hp Frame
360 360 224 300 2
650 650 445 600 3A
1K2 1250 860 1150 3B

c3
ND Rating
600V, 60 Hz Input
Code Amps kW Hp Frame
425 425 345 465 3A
800 800 650 870 3B

c4
ND Rating
690V, 60 Hz Input
Code Amps kW Hp Frame
380 380 355 475 3A
705 705 657 881 3B

d
Enclosure
Code Enclosure Conformal Coating
A IP20, NEMA/UL Type 1 §  No
N IP00, Open Chassis §  No
§ Frames 3A & 3B complete drive.
§ Frame 2 only.

e
HIM
Code Operator Interface
0 No HIM/Blank Cover
3 Full Numeric LCD (Frame 2 Only)
C Full Numeric LCD, Door Mount (Frames 3A & 3B Only)

f
Documentation
Code Documents Ship Carton
E English Doc Set Yes
N No Documentation Yes

g
Brake
Code w/Brake IGBT
N No

h
Brake Resistor
Code w/Resistor
N No

i
Equipment Type
Code Description Frame
A Complete Regenerative Drive 2, 3A & 3B

j
Comm Slot
Code Communication Option DPI™ User Installed Kit Cat. No. ‡ 
N None N
C DPI ControlNet (Coax) ¬  20-Comm-C
D DPI DeviceNet ¬  20-Comm-D
E DPI EtherNet/IP ¬  20-Comm-E
R DPI RIO ¬  20-Comm-R
S DPI RS-485 DF1 ¬  20-Comm-S
1 DriveLogix™ ControlNet (Coax) T  -
2 DriveLogix ControlNet Redundant (Coax) T  -
3 DriveLogix ControlNet (Fiber) T  -
4 DriveLogix ControlNet Redundant (Fiber) T  -
5 DriveLogix DeviceNet (Open Conn.) T  -
6 DriveLogix EtherNet/IP T  -
¬ 700 Vector Control uses DPI comm. slot options only.
T DriveLogix comm. slot options require 700S Phase II Control with DriveLogix5730.
‡ For 700S Phase II Control with DriveLogix5730, comm. slot option selections are mutually exclusive. For two communication adapters, (DPI and DriveLogix), select the DriveLogix comm. slot option and order the DPI user installed kit catalog number separately.

k
Control Options
Code Control Cassette Logic Expansion Synch-Link
1 700VC 24V I/O Base N/A N/A
2 700VC 120V I/O Base N/A N/A
A 700S Phase II Expanded No No
B 700S Phase II Expanded No Yes
C 700S Phase II Expanded Yes No § 
D 700S Phase II Expanded Yes Yes § 
§ Requires DriveLogix5730.

l
Feedback
Code Control Option Type
0 All None
1 700VC Encoder 5V/12V
A 700S Ph. II Resolver § 
B 700S Ph. II Stegmann Hi-Resolution Encoder § 
C 700S Ph. II Multi-Device Interface § Ø 
E 700S Ph. II 2nd Encoder § 
§ Expanded cassette required.
Ø Multi-Device Interface allows the connection of the Stegmann and Temposonics linear sensors. The Temposonics sensor cannot be used to close motor control or speed loops.

m
Additional Config.
Code Logix Option Embedded Comm.
W None -
E Phase II Control No
K Phase II Control w/DriveLogix5730 No
L Phase II Control w/DriveLogix5730 EtherNet/IP

n
Coolant Type
Code Coolant Frame
A Water All