PowerFlex 755

Click to enlarge - PF755_Grp
PowerFlex 755 AC Drive


The PowerFlex 755 AC drive will maximize your investment and help improve productivity. Ideal for applications that require safety, high motor control performance, and application flexibility, the PowerFlex 755 is a highly functional and cost effective solution.

The PowerFlex 755 AC drive offers customers more selection for control and supporting hardware options than any other drive in its class including:



Conformity to Standards

The PowerFlex 755 drive conforms to the following:

UL Listed ü NEMA ü
c-UL ü ROHS Compliant ü
SEMI F47 ü TUV FS ü
CE Approved ü EMC (EN 61800-3) ü
C-Tick ü Low Voltage (EN 61800-5-1) ü
 

Drive Description

Designed for ease of integration, application flexibility and performance, the PowerFlex® 755 AC drive provides greater functionality across your manufacturing systems and is available in the following ratings; 7.5…250 kW / 10…350 Hp at 400/480V AC & 540/650V DC input.

The PowerFlex 755 AC drive is aimed to maximize your investment and help improve productivity. Ideal for applications that require safety, high motor control performance, and application flexibility, the PowerFlex 755 is a highly functional and cost effective solution.

The PowerFlex 755 AC drive offers customers more selection for control and supporting hardware options than any other drive in its class. Offering the latest technologies standard:



Available with two Safety options, a Safe Torque-Off only option and a Safe Speed Monitor option which also includes Safe Torque-Off, Rockwell Automation Safe Speed Control Technology, Door Control, and an Embedded Safety relay.

Multiple feedback interfaces to support a wide range of applications including Incremental, EnDat and Hiperface for Stegmann and Heidenhain high resolution feedbacks, SSI for Stahltronis and Temposonics and BiSS for linear feedback.

The PowerFlex 755 comes Standard with (1) Digital Input which supports either 24V DC or 120V AC, but offers a variety of I/O options to meet application requirements.

A Human Interface Module (HIM) offers an LCD display for six lines of text providing meaningful explanations of parameters, events, and the Assisted Start-up Routine. The HIM is compatible with the PowerFlex 70, 700, 700S, and 700H drives and is available in NEMA 1 and NEMA 4 versions.

In addition to Embedded Ethernet/IP, the PowerFlex 755 supports:



Catalog Number Explanation

To interpret the meaning of a catalog number, match the values of the catalog number code in positions a, b, c, etc. with the tables labeled a, b, c, etc. below.

20G   1   1   N   D   248   A   A   0   N   N   N   N   N
a   b   c   d   e   f   g   h                        

a
Drive
Code Type
20G PowerFlex 755

b
Future Use

c
Input Type
Code Description Frames
1 6 Pulse, w/DC Terminals 2…7
A 6 Pulse, w/o DC Terminals 6, 7

d
Enclosure
Code Description
F Flange (NEMA/UL Type 4X back) §  ‡ 
G IP54, NEMA/UL Type 12 § 
N IP20/IP00, NEMA/UL Type Open T 
‡ For Frames 6…7 a User Installed Flange Kit is available that provides a NEMA/UL Type 4X back.
§ Frames 2…5 only.
T Frames 2…5 are IP20, Frames 6…7 are IP00.

e
Voltage Rating
Code Voltage
C 400V AC
D 480V AC

f1
ND Rating
400V, 50 Hz Input
Code Amps kW Frame
Enclosure Codes F and N Enclosure Code G
015 15.4 7.5 2 2
022 22 11 2 2
030 30 15 3 3
037 37 18.5 3 3
043 43 22 3 3
060 60 30 4 4
072 72 37 4 5
085 85 45 5 5
104 104 55 5
140 140 75 6
170 170 90 6
205 205 110 6
260 260 132 6
302 302 160 7
367 367 200 7
456 456 250 7

f2
ND Rating
480V, 60 Hz Input
Code Amps Hp Frame
Enclosure Codes F and N Enclosure Code G
014 14 10 2 2
022 22 15 2 2
027 27 20 3 3
034 34 25 3 3
040 40 30 3 3
052 52 40 4 4
065 65 50 4 5
077 77 60 5 5
096 96 75 5
125 125 100 6
156 156 125 6
186 186 150 6
248 248 200 6
302 302 250 7
361 361 300 7
415 415 350 7

g
Filtering and CM Cap Configuration
Code Filtering Default CM Cap Connection
A Ø  Yes Jumper Removed
J Ø  Yes Jumper Installed
Ø  In all cases, jumpers are included for field reconfiguration as desired.

h
Dynamic Braking
Code Internal Resistor z  Internal Transistor ª 
A No Yes
B Yes Yes
N No No
z  Frame 2 only.
ª  Standard on Frames 2…5, Optional on Frames 6…7.

Hardware Control Options

Build a Catalog Number


Click to enlarge - PF755_open



IP00/IP20, NEMA/UL Type Open (Position d = N) T 

380…480V AC, Three-Phase Drives
480V AC Input 380…400V AC Input Frame Size
Output Amps Normal Duty Hp Heavy Duty Hp Cat. No. ¬  Output Amps Normal Duty kW Heavy Duty kW Cat. No. ¬ 
Cont. 1 Min. 3 Sec. Cont. 1 Min. 3 Sec.
14 (11) 15.4 (16.5) 21 (21) 10 7.5 20G11ND014AA0NNNNN 15.4 (11.5) 16.9 (17.3) 23.1 (23.1) 7.5 5.5 20G11NC015JA0NNNNN 2
22 (14) 24.2 (24.2) 33 (33) 15 10 20G11ND022AA0NNNNN 22 (15.4) 24.2 (24.2) 33 (33) 11 7.5 20G11NC022JA0NNNNN 2
27 (22) 29.7 (33) 40.5 (40.5) 20 15 20G11ND027AA0NNNNN 30 (22) 33 (33) 45 (45) 15 11 20G11NC030JA0NNNNN 3
34 (27) 37.4 (40.5) 51 (51) 25 20 20G11ND034AA0NNNNN 37 (30) 40.7 (45) 55.5 (55.5) 18.5 15 20G11NC037JA0NNNNN 3
40 (34) 44 (51) 60 (61.2) 30 25 20G11ND040AA0NNNNN 43 (37) 47.3 (55.5) 64.5 (66.6) 22 18.5 20G11NC043JA0NNNNN 3
52 (40) 57.2 (60) 78 (78) 40 30 20G11ND052AA0NNNNN 60 (43) 66 (66) 90 (90) 30 22 20G11NC060JA0NNNNN 4
65 (52) 71.5 (78) 97.5 (97.5) 50 40 20G11ND065AA0NNNNN 72 (60) 79.2 (90) 108 (108) 37 30 20G11NC072JA0NNNNN 4
77 (65) 84.7 (97.5) 115.5 (117) 60 50 20G11ND077AA0NNNNN 85 (72) 93.5 (108) 127.5 (129.6) 45 37 20G11NC085JA0NNNNN 5
96 (77) 105.6 (115.5) 144 (144) 75 60 20G11ND096AA0NNNNN 104 (85) 114.4 (127.5) 156 (156) 55 45 20G11NC104JA0NNNNN 5
125 (96) 137.5 (144) 187.5 (187.5) 100 75 20G1AND125AN0NNNNN 140 (104) 154 (156) 210 (210) 75 55 20G1ANC140JN0NNNNN 6
156 (125) 171.6 (187.5) 234 (234) 125 100 20G1AND156AN0NNNNN 170 (140) 187 (210) 255 (255) 90 75 20G1ANC170JN0NNNNN 6
186 (156) 204.6 (234) 279 (280.8) 150 125 20G1AND186AN0NNNNN 205 (170) 225.5 (255) 307.5 (307.5) 110 90 20G1ANC205JN0NNNNN 6
248 (186) 272.8 (279) 372 (372) 200 150 20G1AND248AN0NNNNN 260 (205) 286 (307.5) 390 (390) 132 110 20G1ANC260JN0NNNNN 6
302 (248) 332.2 (372) 453 (453) 250 200 20G1AND302AN0NNNNN 302 (260) 332.2 (390) 453 (468) 160 132 20G1ANC302JN0NNNNN 7
361 (302) 397.1 (453) 541.5 (543.6) 300 250 20G1AND361AN0NNNNN 367 (302) 403.7 (453) 550.5 (550.5) 200 160 20G1ANC367JN0NNNNN 7
415 (361) 456.5 (541.5) 622.5 (649.8) 350 300 20G1AND415AN0NNNNN 456 (367) 501.6 (550.5) 684 (684) 250 200 20G1ANC456JN0NNNNN 7
  
¬ Refer to the Catalog Number Explanation or Factory Installed Options for descriptions.
T Frames 2…5 are IP20, Frames 6…7 are IP00.

IP54, NEMA/UL Type 12 (Position d = G)

380…480V AC, Three-Phase Drives
480V AC Input 380…400V AC Input Frame Size
Output Amps Normal Duty Hp Heavy Duty Hp Cat. No. ¬  Output Amps Normal Duty kW Heavy Duty kW Cat. No. ¬ 
Cont. 1 Min. 3 Sec. Cont. 1 Min. 3 Sec.
14 (11) 15.4 (16.5) 21 (21) 10 7.5 20G11GD014AA0NNNNN 15.4 (11.5) 16.9 (17.3) 23.1 (23.1) 7.5 5.5 20G11GC015JA0NNNNN 2
22 (14) 24.2 (24.2) 33 (33) 15 10 20G11GD022AA0NNNNN 22 (15.4) 24.2 (24.2) 33 (33) 11 7.5 20G11GC022JA0NNNNN 2
27 (22) 29.7 (33) 40.5 (40.5) 20 15 20G11GD027AA0NNNNN 30 (22) 33 (33) 45 (45) 15 11 20G11GC030JA0NNNNN 3
34 (27) 37.4 (40.5) 51 (51) 25 20 20G11GD034AA0NNNNN 37 (30) 40.7 (45) 55.5 (55.5) 18.5 15 20G11GC037JA0NNNNN 3
40 (34) 44 (51) 60 (61.2) 30 25 20G11GD040AA0NNNNN 43 (37) 47.3 (55.5) 64.5 (66.6) 22 18.5 20G11GC043JA0NNNNN 3
52 (40) 57.2 (60) 78 (78) 40 30 20G11GD052AA0NNNNN 60 (43) 66 (66) 90 (90) 30 22 20G11GC060JA0NNNNN 4
65 (52) 71.5 (78) 97.5 (97.5) 50 40 20G11GD065AA0NNNNN 72 (60) 79.2 (90) 108 (108) 37 30 20G11GC072JA0NNNNN 5
77 (65) 84.7 (97.5) 115.5 (117) 60 50 20G11GD077AA0NNNNN 85 (72) 93.5 (108) 127.5 (129.6) 45 37 20G11GC085JA0NNNNN 5
  
¬ Refer to the Catalog Number Explanation or Factory Installed Options for descriptions.

Flange Mount
Front = IP20, NEMA/UL Type Open, Back/Heatsink = IP66, NEMA/UL Type 4X/12 (Position d = F)


380…480V AC, Three-Phase Drives
480V AC Input 380…400V AC Input Frame Size
Output Amps Normal Duty Hp Heavy Duty Hp Cat. No. ¬  Output Amps Normal Duty kW Heavy Duty kW Cat. No. ¬ 
Cont. 1 Min. 3 Sec. Cont. 1 Min. 3 Sec.
14 (11) 15.4 (16.5) 21 (21) 10 7.5 20G11FD014AA0NNNNN 15.4 (11.5) 16.9 (17.3) 23.1 (23.1) 7.5 5.5 20G11FC015JA0NNNNN 2
22 (14) 24.2 (24.2) 33 (33) 15 10 20G11FD022AA0NNNNN 22 (15.4) 24.2 (24.2) 33 (33) 11 7.5 20G11FC022JA0NNNNN 2
27 (22) 29.7 (33) 40.5 (40.5) 20 15 20G11FD027AA0NNNNN 30 (22) 33 (33) 45 (45) 15 11 20G11FC030JA0NNNNN 3
34 (27) 37.4 (40.5) 51 (51) 25 20 20G11FD034AA0NNNNN 37 (30) 40.7 (45) 55.5 (55.5) 18.5 15 20G11FC037JA0NNNNN 3
40 (34) 44 (51) 60 (61.2) 30 25 20G11FD040AA0NNNNN 43 (37) 47.3 (55.5) 64.5 (66.6) 22 18.5 20G11FC043JA0NNNNN 3
52 (40) 57.2 (60) 78 (78) 40 30 20G11FD052AA0NNNNN 60 (43) 66 (66) 90 (90) 30 22 20G11FC060JA0NNNNN 4
65 (52) 71.5 (78) 97.5 (97.5) 50 40 20G11FD065AA0NNNNN 72 (60) 79.2 (90) 108 (108) 37 30 20G11FC072JA0NNNNN 4
77 (65) 84.7 (97.5) 115.5 (117) 60 50 20G11FD077AA0NNNNN 85 (72) 93.5 (108) 127.5 (129.6) 45 37 20G11FC085JA0NNNNN 5
96 (77) 105.6 (115.5) 144 (144) 75 60 20G11FD096AA0NNNNN 104 (85) 114.4 (127.5) 156 (156) 55 45 20G11FC104JA0NNNNN 5
  
¬ Refer to the Catalog Number Explanation or Factory Installed Options for descriptions.

DC Input Drives

DC input drives will use the same catalog number as the corresponding AC input drives. Frames 2…5 include DC input terminals. DC Bus Bars are a factory installed option for Frames 6…7 (see Factory Installed Options). User installed kits are also available (see DC Bus Bar Option Kits).

Factory Installed Options

DC Terminals/Bus Bars
Description Frame Cat. Code
DC Terminals 2…5 1
DC Bus Bars 6 1
7 1
  

Internal Brake IGBT and Brake Resistor
Drive Input Voltage Description Frame Cat. Code
(Position h)
380…480V AC Brake IGBT Only 2…5 A
6 A
7 A
Brake IGBT w/Internal DB Resistor (68 ohms) 2 B
No Brake IGBT or Internal DB Resistor All N
  

User Installed Options

Human Interface Modules
Description Cat. No.
No HIM (Blank Plate) 20-HIM-A0
Enhanced, LCD, Full Numeric 20-HIM-A6
Enhanced, LCD, Full Numeric, NEMA/UL Type 4 ‡  20-HIM-C6S
Wireless Interface Module 20-WIM-N1
Wireless Interface Module, Remote (Panel Mount) ‡  20-WIM-N4S
  
‡ Includes an interface cable (1202-C30) for connection to drive.

Human Interface Module Accessories
Description Cat. No.
Bezel Kit for LCD HIMs, NEMA/UL Type 1 ‡  20-HIM-B1
PowerFlex HIM Interface Cable, 1 m (39 in) §  20-HIM-H10
Cable Kit (Male-Female) Ø 
0.33 Meters (1.1 Feet)
1202-H03
1 Meter (3.3 Feet)
1202-H10
3 Meter (9.8 Feet)
1202-H30
9 Meter (29.5 Feet)
1202-H90
DPI/SCANport™ One to Two Port Splitter Cable 1203-S03
  
‡ Includes an interface cable (1202-C30) for connection to drive.
§ Required only when HIM is used as handheld or remote.
Ø Required in addition to 20-HIM-H10 for distances up to a total maximum of 10 Meters (32.8 Feet).

Communication Option Kits
Description Cat. No.
DeviceNet Option Module 20-750-DNET
Communication Carrier Card ¬  20-750-20COMM
  
¬ Allows the use of a Legacy Communication Adapter with the PowerFlex 755 (see Legacy Communication Option Kits).

Control and I/O Options
Description Cat. No.
2262 I/O (24V) with 2 Relay Outputs 20-750-2262C-2R
2262 I/O (115V) with 2 Relay Outputs 20-750-2262D-2R
2263 I/O (24V) with 1 Relay and 2 Transistor Outputs 20-750-2263C-1R2T
  

Safety Options and Auxiliary Control Power Supply
Description Cat. No.
Safe Torque Off 20-750-S
Safe Speed Monitor 20-750-S1
24V Aux Power Supply 20-750-APS
  

Feedback Option Kits
Description Cat. No.
Incremental Encoder 20-750-ENC-1
Dual Incremental Encoder 20-750-DENC-1
Universal Feedback 20-750-UFB-1
  

Flange Adapter Kit
NEMA/UL Frame Cat. No.
Type 1 2 20-750-FLNG1-F2
Type 1 3 20-750-FLNG1-F3
Type 1 4 20-750-FLNG1-F4
Type 1 5 20-750-FLNG1-F5
Type 4X 6 20-750-FLNG4-F6
Type 4X 7 20-750-FLNG4-F7
  

EMC Option Kits
Description Frame Cat. No.
EMC Plate with Core 2 20-750-EMC1-F2
EMC Plate with Core 3 20-750-EMC1-F3
EMC Plate with Cores 4 20-750-EMC1-F4
EMC Plate with Cores 5 20-750-EMC1-F5
EMC Core 2 20-750-EMC2-F2
EMC Core 3 20-750-EMC2-F3
EMC Cores 4…5 20-750-EMC2-F45
  

NEMA/UL Type 1 Option Kits
Description Frame Cat. No.
NEMA/UL Type 1 Kit 2 20-750-NEMA1-F2
NEMA/UL Type 1 Kit 3 20-750-NEMA1-F3
NEMA/UL Type 1 Kit 4 20-750-NEMA1-F4
NEMA/UL Type 1 Kit 5 20-750-NEMA1-F5
NEMA/UL Type 1 Kit 6 20-750-NEMA1-F6
NEMA/UL Type 1 Kit 7 20-750-NEMA1-F7
  

DC Bus Bar Option Kits
Description Frame Cat. No.
DC Terminals 2…5 Standard
DC Bus Bars 6 20-750-DCBB1-F6
7 20-750-DCBB1-F7
  

Internal Dynamic Brake Resistor Kits

These resistors have a limited duty cycle. Refer to the PowerFlex Dynamic Braking Selection Guide to determine if an internal resistor will be sufficient for your application. An external resistor may be required.

Drive Input Voltage Brake Resistance Frame Cat. No.
W
380…480V AC Internal Brake Resistor, 68 ohms 2 20-750-DB1-D2
  

Dynamic Brake, Chopper Only Kits
Description Rating Cat. No.
380…480V AC 9A 1336-WB009
35A 1336-WB035
110A 1336-WB110
  

Legacy Communication Options

Most legacy communication adapters (20-COMM) can be used with the PowerFlex 755. However, the restrictions stated below do apply.

Legacy Adapter Compatibility
Adapter Accesses Ports 1…6 for I/O Accesses Port 7… 14 Devices Supports Drive Add On Profiles Supports Asian-Languages Ø 
20-COMM-B Not Compatible
20-COMM-C üT  ü v3.001 §  ü §  ü v3.001 § 
20-COMM-D ü v2.005 §  Not Compatible
20-COMM-E ü v4.001 §  ü §  ü v4.001 § 
20-COMM-H ü‡  Not Compatible
20-COMM-I üT 
20-COMM-K
20-COMM-L Not Compatible
20-COMM-M üT  ü v2.001 §  Not Compatible ü v2.001 § 
20-COMM-P Not Compatible
20-COMM-Q ü v3.001 §  ü §  ü v3.001 § 
20-COMM-R Not Compatible
20-COMM-S
  
T Controller must be capable of reading/writing 32-bit floating point (REAL) values.
‡ Only works in the Modbus RTU mode.
§ Requires this adapter firmware version or higher.
§ Requires firmware version v1.05 or higher of the drive Add On Profiles for RSLogix 5000 version v16 or higher.
Ø Chinese, Japanese, and Korean languages are supported at the time of publication.

Legacy Communication Option Kits
Description Cat. No.
ControlNet™ Communication Adapter (Coax) 20-COMM-C
ControlNet™ Communication Adapter (Coax) Conformal Coat 20-COMM-C-MX3
DeviceNet™ Communication Adapter 20-COMM-D
DeviceNet™ Communication Adapter Conformal Coat 20-COMM-D-MX3
EtherNet/IP™ Communication Adapter 20-COMM-E
EtherNet/IP™ Communication Adapter Conformal Coat 20-COMM-E-MX3
HVAC Communication Adapter v  20-COMM-H
HVAC Communication Adapter Conformal Coat v  20-COMM-H-MX3
Interbus™ Communication Adapter 20-COMM-I
CANopen® Communication Adapter 20-COMM-K
Modbus/TCP Communication Adapter 20-COMM-M
PROFIBUS™ DP Communication Adapter 20-COMM-P
ControlNet™ Communication Adapter (Fiber) 20-COMM-Q
Remote I/O Communication Adapter 20-COMM-R
Remote I/O Communication Adapter Conformal Coat 20-COMM-R-MX3
RS485 DF1 Communication Adapter 20-COMM-S
RS485 DF1 Communication Adapter Conformal Coat 20-COMM-S-MX3
External Communications Kit Power Supply 20-XCOMM-AC-PS1
DPI External Communications Kit 20-XCOMM-DC-BASE
External DPI I/O Option Board ‡  20-XCOMM-IO-OPT1
Compact I/O Module (3 Channel) 1769-SM1
ControlNet Ex Right-Angle T-Tap 1786-TPR
Serial Null Modem Adapter 1203-SNM
Smart Self-powered Serial Converter (RS232) includes 1203-SFC and 1202-C10 Cables 1203-SSS
Universal Serial Bus™ (USB) Converter includes 2m USB, 20-HIM-H10 & 22-HIM-H10 Cables 1203-USB
  
‡ For use only with DPI External Communications Kits 20-XCOMM-DC-BASE.
v  Only Modbus RTU can be used.

PC Programming Software
Description
DriveTools™ SP Software ª 
DriveExplorer™ Software (Lite/Full) ª v 
 
ª Set-up wizards are available for use with DriveTools SP and DriveExplorer (Lite/Full).
v DriveExplorer Lite is available for free download at: http://www.ab.com/drives/driveexplorer/free_download.html.

Terminators
Description ª  Cat. No.
for use with 1.5 kW (2 Hp) & up drives 1204-TFB2
  
ª Refer to Appendix A of publication DRIVES-IN001 for selection information.

Reflected Wave Reduction Modules w/Common Mode Choke
Description ª  Cat. No.
17A with Common Mode Choke 1204-RWC-17-A
  
ª Refer to Appendix A of publication DRIVES-IN001 for selection information.

Reflected Wave Reduction Modules
Voltage Drive Cat. No.
20G…
ND Hp Cat. No.
400/480V AC 014 10 1321-RWR18-DP
022 15 1321-RWR25-DP
027 20 1321-RWR25-DP
034 25 1321-RWR35-DP
040 30 1321-RWR45-DP
052 40 1321-RWR55-DP
065 50 1321-RWR80-DP
077 60 1321-RWR80-DP
096 75 1321-RWR100-DP
125 100 1321-RWR130-DP
156 125 1321-RWR160-DP
186 150 1321-RWR200-DP
248 200 1321-RWR250-DP
302 250 1321-RWR320-DP
  

Isolation Transformers
Motor Rating kW (Hp) 460V, 60 Hz, Three-Phase, 460V Primary & 460V Secondary
IP32 (NEMA Type 3R)
Cat. No.
7.5 (10) 1321-3TW014-BB
11 (15) 1321-3TW020-BB
15 (20) 1321-3TW027-BB
18.5 (25) 1321-3TW034-BB
22 (30) 1321-3TW040-BB
30 (40) 1321-3TW051-BB
37 (50) 1321-3TH063-BB
45 (60) 1321-3TH075-BB
55 (75) 1321-3TH093-BB
75 (100) 1321-3TH118-BB
90 (125) 1321-3TH145-BB
110 (150) 1321-3TH175-BB
132 (200) 1321-3TH220-BB
160 (250) 1321-3TH275-BB
200 (300) 1321-3TH330-BB
250 (350) 1321-3TH440-BB
  

Input and Output Line Reactors - 480V, 60 Hz, Three-Phase, 3% Impedance
Drive Cat. No.
20GD…
Duty Hp Input Line Reactor T  Output Line Reactor T 
IP00 (Open Style) IP11 (NEMA Type 1) IP00 (Open Style) IP11 (NEMA Type 1)
Cat. No. Cat. No. Cat. No. Cat. No.
014 Normal Duty 10 1321-3R18-B 1321-3RA18-B 1321-3R18-B 1321-3RA18-B
022 Heavy Duty 10 1321-3R18-B 1321-3RA18-B 1321-3R25-B 1321-3RA25-B
022 Normal Duty 15 1321-3R25-B 1321-3RA25-B 1321-3R25-B 1321-3RA25-B
027 Heavy Duty 15 1321-3R25-B 1321-3RA25-B 1321-3R25-B 1321-3RA25-B
027 Normal Duty 20 1321-3R35-B 1321-3RA35-B 1321-3R25-B 1321-3RA25-B
034 Heavy Duty 20 1321-3R35-B 1321-3RA35-B 1321-3R35-B 1321-3RA35-B
034 Normal Duty 25 1321-3R35-B 1321-3RA35-B 1321-3R35-B 1321-3RA35-B
040 Heavy Duty 25 1321-3R35-B 1321-3RA35-B 1321-3R45-B 1321-3RA45-B
040 Normal Duty 30 1321-3R45-B 1321-3RA45-B 1321-3R45-B 1321-3RA45-B
052 Heavy Duty 30 1321-3R45-B 1321-3RA45-B 1321-3R55-B 1321-3RA55-B
052 Normal Duty 40 1321-3R55-B 1321-3RA55-B 1321-3R55-B 1321-3RA55-B
065 Heavy Duty 40 1321-3R55-B 1321-3RA55-B 1321-3R80-B 1321-3RA80-B
065 Normal Duty 50 1321-3R80-B 1321-3RA80-B 1321-3R80-B 1321-3RA80-B
077 Heavy Duty 50 1321-3R80-B 1321-3RA80-B 1321-3R80-B 1321-3RA80-B
077 Normal Duty 60 1321-3R80-B 1321-3RA80-B 1321-3R80-B 1321-3RA80-B
096 Heavy Duty 60 1321-3R80-B 1321-3RA80-B 1321-3R80-B 1321-3RA80-B
096 Normal Duty 75 1321-3R100-B 1321-3RA100-B 1321-3R100-B 1321-3RA100-B
125 Heavy Duty 75 1321-3R100-B 1321-3RA100-B 1321-3R100-B 1321-3RA100-B
125 Normal Duty 100 1321-3R130-B 1321-3RA130-B 1321-3R130-B 1321-3RA130-B
156 Heavy Duty 100 1321-3R130-B 1321-3RA130-B 1321-3R130-B 1321-3RA130-B
156 Normal Duty 125 1321-3R160-B 1321-3RA160-B 1321-3R160-B 1321-3RA160-B
186 Heavy Duty 125 1321-3R160-B 1321-3RA160-B 1321-3R160-B 1321-3RA160-B
186 Normal Duty 150 1321-3R200-B 1321-3RA200-B 1321-3R200-C 1321-3RA200-C
248 Heavy Duty 150 1321-3R200-B 1321-3RA200-B 1321-3R200-C 1321-3RA200-C
248 Normal Duty 200 1321-3RB250-B 1321-3RAB250-B 1321-3RB250-B 1321-3RAB250-B
302 Heavy Duty 200 1321-3RB320-B 1321-3RAB320-B 1321-3RB320-B 1321-3RAB320-B
302 Normal Duty 250 1321-3RB320-B 1321-3RAB320-B 1321-3RB320-B 1321-3RAB320-B
361 Heavy Duty 200 1321-3RB320-B 1321-3RAB320-B 1321-3RB320-B 1321-3RAB320-B
361 Normal Duty 300 1321-3RB400-B 1321-3RAB400-B 1321-3RB400-B 1321-3RAB400-B
415 Heavy Duty 300 1321-3RB400-B 1321-3RAB400-B 1321-3RB400-B 1321-3RAB400-B
415 Normal Duty 350 1321-3RB400-B 1321-3RAB400-B 1321-3RB400-B 1321-3RAB400-B
  
T  Input line reactors were sized based on the NEC fundamental motor amps. Output line reactors were sized based on the VFD rated output currents.

Input and Output Line Reactors - 480V, 60 Hz, Three-Phase, 5% Impedance
Drive Cat. No.
20GD …
Duty Hp Input Line Reactor T  Output Line Reactor T 
IP00 (Open Style) IP11 (NEMA Type 1) IP00 (Open Style) IP11 (NEMA Type 1)
Cat. No. Cat. No. Cat. No. Cat. No.
014 Normal Duty 10 1321-3R18-C 1321-3RA18-C 1321-3R18-C 1321-3RA18-C
022 Heavy Duty 10 1321-3R18-C 1321-3RA18-C 1321-3R25-C 1321-3RA25-C
022 Normal Duty 15 1321-3R25-C 1321-3RA25-C 1321-3R25-C 1321-3RA25-C
027 Heavy Duty 15 1321-3R25-C 1321-3RA25-C 1321-3R25-C 1321-3RA25-C
027 Normal Duty 20 1321-3R35-C‡  1321-3RA35-C‡  1321-3R25-C 1321-3RA25-C
034 Heavy Duty 20 1321-3R35-C‡  1321-3RA35-C‡  1321-3R35-C 1321-3RA35-C
034 Normal Duty 25 1321-3R35-C 1321-3RA35-C 1321-3R35-C 1321-3RA35-C
040 Heavy Duty 25 1321-3R35-C 1321-3RA35-C 1321-3R45-C 1321-3RA45-C
040 Normal Duty 30 1321-3R45-C 1321-3RA45-C 1321-3R45-C 1321-3RA45-C
052 Heavy Duty 30 1321-3R45-C 1321-3RA45-C 1321-3R55-C 1321-3RA55-C
052 Normal Duty 40 1321-3R55-C 1321-3RA55-C 1321-3R55-C 1321-3RA55-C
065 Heavy Duty 40 1321-3R55-C 1321-3RA55-C 1321-3R80-C 1321-3RA80-C
065 Normal Duty 50 1321-3R80-C 1321-3RA80-C 1321-3R80-C 1321-3RA80-C
077 Heavy Duty 50 1321-3R80-C 1321-3RA80-C 1321-3R80-C 1321-3RA80-C
077 Normal Duty 60 1321-3R80-C 1321-3RA80-C 1321-3R80-C 1321-3RA80-C
096 Heavy Duty 60 1321-3R80-C 1321-3RA80-C 1321-3R80-C 1321-3RA80-C
096 Normal Duty 75 1321-3R100-C 1321-3RA100-C 1321-3R100-C 1321-3RA100-C
125 Heavy Duty 75 1321-3R100-C 1321-3RA100-C 1321-3R100-C 1321-3RA100-C
125 Normal Duty 100 1321-3R130-C 1321-3RA130-C 1321-3R130-C 1321-3RA130-C
156 Heavy Duty 100 1321-3R130-C 1321-3RA130-C 1321-3R130-C 1321-3RA130-C
156 Normal Duty 125 1321-3R160-C 1321-3RA160-C 1321-3R160-C 1321-3RA160-C
186 Heavy Duty 125 1321-3R160-C 1321-3RA160-C 1321-3R160-C 1321-3RA160-C
186 Normal Duty 150 1321-3R200-C 1321-3RA200-C 1321-3R200-C‡  1321-3RA200-C‡ 
248 Heavy Duty 150 1321-3R200-C 1321-3RA200-C 1321-3R200-C‡  1321-3RA200-C‡ 
248 Normal Duty 200 1321-3RB250-C 1321-3RAB250-C 1321-3RB250-C 1321-3RAB250-C
302 Heavy Duty 200 1321-3RB320-C 1321-3RAB320-C 1321-3RB320-C 1321-3RAB320-C
302 Normal Duty 250 1321-3RB320-C 1321-3RAB320-C 1321-3RB320-C 1321-3RAB320-C
361 Heavy Duty 250 1321-3RB320-C 1321-3RAB320-C 1321-3RB320-C 1321-3RAB320-C
361 Normal Duty 300 1321-3RB400-C 1321-3RAB400-C 1321-3RB400-C 1321-3RAB400-C
415 Heavy Duty 300 1321-3RB400-C 1321-3RAB400-C 1321-3RB400-C 1321-3RAB400-C
415 Normal Duty 350 1321-3R500-C 1321-3RA500-C 1321-3RB400-C 1321-3RAB400-C
  
T  Input line reactors were sized based on the NEC fundamental motor amps. Output line reactors were sized based on the VFD rated output currents.
‡ 4% impedance.