Catalogs > Drives Catalog > PowerFlex 755
PowerFlex 755
| Introduction | Conformity to Standards | Drive Description | Catalog Number Explanation | Hardware Control Options | Factory Installed Options | User Installed Options |
To interpret the meaning of a catalog number, match the values of the catalog number code in positions a, b, c, etc. with the tables labeled a, b, c, etc. below.
| 20G | 1 | 1 | N | D | 248 | A | A | 0 | N | N | N | N | N | |||||||||||||
| a | b | c | d | e | f | g | h |
| a | |
| Drive | |
| Code | Type |
| 20G | PowerFlex 755 |
| b |
| Future Use |
| c | ||
| Input Type | ||
| Code | Description | Frames |
| 1 | 6 Pulse, w/DC Terminals | 2…7 |
| A | 6 Pulse, w/o DC Terminals | 6, 7 |
| d | |
| Enclosure | |
| Code | Description |
| F | Flange (NEMA/UL Type 4X back) § |
| G | IP54, NEMA/UL Type 12 § |
| N | IP20/IP00, NEMA/UL Type Open T |
| For Frames 6…7 a User Installed Flange Kit is available that provides a NEMA/UL Type 4X back. | |
| § Frames 2…5 only. | |
| T Frames 2…5 are IP20, Frames 6…7 are IP00. | |
| e | |
| Voltage Rating | |
| Code | Voltage |
| C | 400V AC |
| D | 480V AC |
| f1 | ||||
| ND Rating | ||||
| 400V, 50 Hz Input | ||||
| Code | Amps | kW | Frame | |
| Enclosure Codes F and N | Enclosure Code G | |||
| 015 | 15.4 | 7.5 | 2 | 2 |
| 022 | 22 | 11 | 2 | 2 |
| 030 | 30 | 15 | 3 | 3 |
| 037 | 37 | 18.5 | 3 | 3 |
| 043 | 43 | 22 | 3 | 3 |
| 060 | 60 | 30 | 4 | 4 |
| 072 | 72 | 37 | 4 | 5 |
| 085 | 85 | 45 | 5 | 5 |
| 104 | 104 | 55 | 5 | |
| 140 | 140 | 75 | 6 | |
| 170 | 170 | 90 | 6 | |
| 205 | 205 | 110 | 6 | |
| 260 | 260 | 132 | 6 | |
| 302 | 302 | 160 | 7 | |
| 367 | 367 | 200 | 7 | |
| 456 | 456 | 250 | 7 | |
| f2 | ||||
| ND Rating | ||||
| 480V, 60 Hz Input | ||||
| Code | Amps | Hp | Frame | |
| Enclosure Codes F and N | Enclosure Code G | |||
| 014 | 14 | 10 | 2 | 2 |
| 022 | 22 | 15 | 2 | 2 |
| 027 | 27 | 20 | 3 | 3 |
| 034 | 34 | 25 | 3 | 3 |
| 040 | 40 | 30 | 3 | 3 |
| 052 | 52 | 40 | 4 | 4 |
| 065 | 65 | 50 | 4 | 5 |
| 077 | 77 | 60 | 5 | 5 |
| 096 | 96 | 75 | 5 | |
| 125 | 125 | 100 | 6 | |
| 156 | 156 | 125 | 6 | |
| 186 | 186 | 150 | 6 | |
| 248 | 248 | 200 | 6 | |
| 302 | 302 | 250 | 7 | |
| 361 | 361 | 300 | 7 | |
| 415 | 415 | 350 | 7 | |
| g | ||
| Filtering and CM Cap Configuration | ||
| Code | Filtering | Default CM Cap Connection |
| A Ø | Yes | Jumper Removed |
| J Ø | Yes | Jumper Installed |
| Ø In all cases, jumpers are included for field reconfiguration as desired. | ||
| h | ||
| Dynamic Braking | ||
| Code | Internal Resistor z | Internal Transistor ª |
| A | No | Yes |
| B | Yes | Yes |
| N | No | No |
| z Frame 2 only. | ||
| ª Standard on Frames 2…5, Optional on Frames 6…7. | ||