IP00/IP20, NEMA/UL Type Open (Position d = N) T 

380…480V AC, Three-Phase Drives
480V AC Input 380…400V AC Input Frame Size
Output Amps Normal Duty Hp Heavy Duty Hp Cat. No. ¬  Output Amps Normal Duty kW Heavy Duty kW Cat. No. ¬ 
Cont. 1 Min. 3 Sec. Cont. 1 Min. 3 Sec.
14 (11) 15.4 (16.5) 21 (21) 10 7.5 20G11ND014AA0NNNNN 15.4 (11.5) 16.9 (17.3) 23.1 (23.1) 7.5 5.5 20G11NC015JA0NNNNN 2
22 (14) 24.2 (24.2) 33 (33) 15 10 20G11ND022AA0NNNNN 22 (15.4) 24.2 (24.2) 33 (33) 11 7.5 20G11NC022JA0NNNNN 2
27 (22) 29.7 (33) 40.5 (40.5) 20 15 20G11ND027AA0NNNNN 30 (22) 33 (33) 45 (45) 15 11 20G11NC030JA0NNNNN 3
34 (27) 37.4 (40.5) 51 (51) 25 20 20G11ND034AA0NNNNN 37 (30) 40.7 (45) 55.5 (55.5) 18.5 15 20G11NC037JA0NNNNN 3
40 (34) 44 (51) 60 (61.2) 30 25 20G11ND040AA0NNNNN 43 (37) 47.3 (55.5) 64.5 (66.6) 22 18.5 20G11NC043JA0NNNNN 3
52 (40) 57.2 (60) 78 (78) 40 30 20G11ND052AA0NNNNN 60 (43) 66 (66) 90 (90) 30 22 20G11NC060JA0NNNNN 4
65 (52) 71.5 (78) 97.5 (97.5) 50 40 20G11ND065AA0NNNNN 72 (60) 79.2 (90) 108 (108) 37 30 20G11NC072JA0NNNNN 4
77 (65) 84.7 (97.5) 115.5 (117) 60 50 20G11ND077AA0NNNNN 85 (72) 93.5 (108) 127.5 (129.6) 45 37 20G11NC085JA0NNNNN 5
96 (77) 105.6 (115.5) 144 (144) 75 60 20G11ND096AA0NNNNN 104 (85) 114.4 (127.5) 156 (156) 55 45 20G11NC104JA0NNNNN 5
125 (96) 137.5 (144) 187.5 (187.5) 100 75 20G1AND125AN0NNNNN 140 (104) 154 (156) 210 (210) 75 55 20G1ANC140JN0NNNNN 6
156 (125) 171.6 (187.5) 234 (234) 125 100 20G1AND156AN0NNNNN 170 (140) 187 (210) 255 (255) 90 75 20G1ANC170JN0NNNNN 6
186 (156) 204.6 (234) 279 (280.8) 150 125 20G1AND186AN0NNNNN 205 (170) 225.5 (255) 307.5 (307.5) 110 90 20G1ANC205JN0NNNNN 6
248 (186) 272.8 (279) 372 (372) 200 150 20G1AND248AN0NNNNN 260 (205) 286 (307.5) 390 (390) 132 110 20G1ANC260JN0NNNNN 6
302 (248) 332.2 (372) 453 (453) 250 200 20G1AND302AN0NNNNN 302 (260) 332.2 (390) 453 (468) 160 132 20G1ANC302JN0NNNNN 7
361 (302) 397.1 (453) 541.5 (543.6) 300 250 20G1AND361AN0NNNNN 367 (302) 403.7 (453) 550.5 (550.5) 200 160 20G1ANC367JN0NNNNN 7
415 (361) 456.5 (541.5) 622.5 (649.8) 350 300 20G1AND415AN0NNNNN 456 (367) 501.6 (550.5) 684 (684) 250 200 20G1ANC456JN0NNNNN 7
  
¬ Refer to the Catalog Number Explanation or Factory Installed Options for descriptions.
T Frames 2…5 are IP20, Frames 6…7 are IP00.

IP54, NEMA/UL Type 12 (Position d = G)

380…480V AC, Three-Phase Drives
480V AC Input 380…400V AC Input Frame Size
Output Amps Normal Duty Hp Heavy Duty Hp Cat. No. ¬  Output Amps Normal Duty kW Heavy Duty kW Cat. No. ¬ 
Cont. 1 Min. 3 Sec. Cont. 1 Min. 3 Sec.
14 (11) 15.4 (16.5) 21 (21) 10 7.5 20G11GD014AA0NNNNN 15.4 (11.5) 16.9 (17.3) 23.1 (23.1) 7.5 5.5 20G11GC015JA0NNNNN 2
22 (14) 24.2 (24.2) 33 (33) 15 10 20G11GD022AA0NNNNN 22 (15.4) 24.2 (24.2) 33 (33) 11 7.5 20G11GC022JA0NNNNN 2
27 (22) 29.7 (33) 40.5 (40.5) 20 15 20G11GD027AA0NNNNN 30 (22) 33 (33) 45 (45) 15 11 20G11GC030JA0NNNNN 3
34 (27) 37.4 (40.5) 51 (51) 25 20 20G11GD034AA0NNNNN 37 (30) 40.7 (45) 55.5 (55.5) 18.5 15 20G11GC037JA0NNNNN 3
40 (34) 44 (51) 60 (61.2) 30 25 20G11GD040AA0NNNNN 43 (37) 47.3 (55.5) 64.5 (66.6) 22 18.5 20G11GC043JA0NNNNN 3
52 (40) 57.2 (60) 78 (78) 40 30 20G11GD052AA0NNNNN 60 (43) 66 (66) 90 (90) 30 22 20G11GC060JA0NNNNN 4
65 (52) 71.5 (78) 97.5 (97.5) 50 40 20G11GD065AA0NNNNN 72 (60) 79.2 (90) 108 (108) 37 30 20G11GC072JA0NNNNN 5
77 (65) 84.7 (97.5) 115.5 (117) 60 50 20G11GD077AA0NNNNN 85 (72) 93.5 (108) 127.5 (129.6) 45 37 20G11GC085JA0NNNNN 5
  
¬ Refer to the Catalog Number Explanation or Factory Installed Options for descriptions.

Flange Mount
Front = IP20, NEMA/UL Type Open, Back/Heatsink = IP66, NEMA/UL Type 4X/12 (Position d = F)


380…480V AC, Three-Phase Drives
480V AC Input 380…400V AC Input Frame Size
Output Amps Normal Duty Hp Heavy Duty Hp Cat. No. ¬  Output Amps Normal Duty kW Heavy Duty kW Cat. No. ¬ 
Cont. 1 Min. 3 Sec. Cont. 1 Min. 3 Sec.
14 (11) 15.4 (16.5) 21 (21) 10 7.5 20G11FD014AA0NNNNN 15.4 (11.5) 16.9 (17.3) 23.1 (23.1) 7.5 5.5 20G11FC015JA0NNNNN 2
22 (14) 24.2 (24.2) 33 (33) 15 10 20G11FD022AA0NNNNN 22 (15.4) 24.2 (24.2) 33 (33) 11 7.5 20G11FC022JA0NNNNN 2
27 (22) 29.7 (33) 40.5 (40.5) 20 15 20G11FD027AA0NNNNN 30 (22) 33 (33) 45 (45) 15 11 20G11FC030JA0NNNNN 3
34 (27) 37.4 (40.5) 51 (51) 25 20 20G11FD034AA0NNNNN 37 (30) 40.7 (45) 55.5 (55.5) 18.5 15 20G11FC037JA0NNNNN 3
40 (34) 44 (51) 60 (61.2) 30 25 20G11FD040AA0NNNNN 43 (37) 47.3 (55.5) 64.5 (66.6) 22 18.5 20G11FC043JA0NNNNN 3
52 (40) 57.2 (60) 78 (78) 40 30 20G11FD052AA0NNNNN 60 (43) 66 (66) 90 (90) 30 22 20G11FC060JA0NNNNN 4
65 (52) 71.5 (78) 97.5 (97.5) 50 40 20G11FD065AA0NNNNN 72 (60) 79.2 (90) 108 (108) 37 30 20G11FC072JA0NNNNN 4
77 (65) 84.7 (97.5) 115.5 (117) 60 50 20G11FD077AA0NNNNN 85 (72) 93.5 (108) 127.5 (129.6) 45 37 20G11FC085JA0NNNNN 5
96 (77) 105.6 (115.5) 144 (144) 75 60 20G11FD096AA0NNNNN 104 (85) 114.4 (127.5) 156 (156) 55 45 20G11FC104JA0NNNNN 5
  
¬ Refer to the Catalog Number Explanation or Factory Installed Options for descriptions.