PowerFlex 700H

Click to enlarge - pf700H_angl


The PowerFlex 700H drive is ideal for high power applications requiring speed control performance. This drive provides excellent torque at low speeds for demanding speed control applications and has configurable control modes for a wide variety of applications. The PowerFlex 700H also has an ATEX certified option for drives that operate in potentially explosive environments.

at a glance …
Ratings
    380…480V:
    500…600V:690:
    

132…1200 kW / 200…1900 Hp / 261…2150 A
150…2400 Hp / 170…2250 A
160…2300 kW / 170…2250 A
Motor Control
  • V/Hz control

  • Sensorless Vector Control
  • Communications Common Industrial Protocol (see Communication Option Kits)
    User Interface HIM (see Human Interface Modules for options)
    Enclosures
  • IP21, NEMA Type 1
  • Safety
  • DriveGuard Safe Torque-Off / EN954-1 Cat. 3
  • Certifications
  • ATEX Certified with Safe Torque-Off

  • C-Tick

  • c-UL, UL

  • CE - with Rittal Enclosure

  • IEC (Designed to Meet) - with Rittal Enclosure

  • TÜV FS ISO/EN13849-1 (EN954-1) with Safe Torque-Off option
  • Additional Information PowerFlex 700H Technical Data, publication 20C-TD001
    PowerFlex 700H Installation Manual, publication PFLEX-IN006
    PowerFlex 700H Programming Manual, publication 20C-PM001
     

    To interpret the meaning of a catalog number, match the values of the catalog number code in positions a, b, c, etc. with the tables labeled a, b, c, etc. below.

    20C    D    261    A    3    A    Y    N    B    N    N    0
    a    b    c1…c4    d    e    f    g    h    i    j    k    l

    a
    Drive
    Code Type
    20C PowerFlex 700H

    b
    Voltage Rating
    Code Voltage Ph.
    C 400V AC 3
    D 480V AC 3
    E 600V AC 3
    F 690V AC 3

    c1
    Rating
    400V, 50Hz Input
    Code Amps - ND (HD) kW - ND (HD)
    261 261 (205) 132 (110)
    300 300 (245) 160 (132)
    385 385 (300) 200 (160)
    460 460 (385) 250 (200)
    500 500 (420) 250 (250)
    590 590 (520) 315 (250)
    650 650 (590) 355 (315)
    730 730 (650) 400 (355)
    820 820 (730) 450 (400)
    920 920 (820) 500 (450)
    1K0 1030 (920) 560 (500)
    1K1 1150 (1030) 630 (560)
    1K3 1300 (1150) 710 (630)
    1K4 1450 (1200) 800 (710)
    1K7 1770 (1600) 1000 (900)
    2K1 2150 (1940) 1200 (1100)

    c2
    Rating
    480V, 60Hz Input
    Code Amps - ND (HD) Hp - ND (HD)
    261 261 (205) 200 (150)
    300 300 (245) 250 (200)
    385 385 (300) 300 (250)
    460 460 (385) 350 (300)
    500 500 (420) 450 (350)
    590 590 (520) 500 (450)
    650 650 (590) 500 (500)
    730 730 (650) 600 (500)
    820 820 (730) 700 (600)
    920 920 (820) 800 (700)
    1K0 1030 (920) 900 (800)
    1K1 1150 (1030) 1000 (900)
    1K3 1300 (1150) 1100 (1000)
    1K4 1450 (1200) 1250 (1000)
    1K7 1770 (1600) 1500 (1400)
    2K1 2150 (1940) 1900 (1700)

    c3
    Rating
    600V, 60Hz Input
    Code Amps - ND (HD) Hp - ND (HD)
    170 170 (144) 150 (150)
    208 208 (170) 200 (150)
    261 261 (208) 250 (200)
    325 325 (261) 350 (250)
    385 385 (325) 400 (350)
    416 416 (325) 450 (350)
    460 460 (385) 500 (400)
    502 502 (460) 500 (500)
    590 590 (502) 600 (500)
    650 650 (590) 700 (650)
    750 750 (650) 800 (700)
    820 820 (750) 900 (700)
    920 920 (820) 1000 (900)
    1K0 1030 (920) 1100 (1000)
    1K1 1180 (1030) 1300 (1100)
    1K5 1500 (1300) 1600 (1400)
    1K9 1900 (1500) 2000 (1600)
    2K2 2250 (1900) 2400 (2000)

    c4
    Rating
    690V, 50Hz Input
    Code Amps - ND (HD) kW - ND (HD)
    170 170 (144) 160 (132)
    208 208 (170) 200 (160)
    261 261 (208) 250 (200)
    325 325 (261) 315 (250)
    385 385 (325) 355 (315)
    416 416 (325) 400 (315)
    460 460 (385) 450 (355)
    502 502 (460) 500 (450)
    590 590 (502) 560 (500)
    650 650 (590) 630 (560)
    750 750 (650) 710 (630)
    820 820 (750) 800 (630)
    920 920 (820) 900 (800)
    1K0 1030 (920) 1000 (900)
    1K1 1180 (1030) 1100 (1000)
    1K5 1500 (1300) 1500 (1300)
    1K9 1900 (1500) 1900 (1500)
    2K2 2250 (1900) 2300 (1900)

    d
    Enclosure
    Code Enclosure
    A IP21, NEMA Type 1 (Frame 9)
    Rittal Enclosure (Frames 10 & Up)
    B IP20, NEMA Type 1, MCC ♣ 
    H IP54, NEMA Type 12, Rittal ♣ 
    K IP20, NEMA Type 1, MCC
    with Conformal Coat ♣ 
    M IP21, NEMA Type 1 (Frame 9)
    Rittal Enclosure (Frames 10 & Up)
    with Conformal Coat
    W IP54, NEMA Type 12, Rittal
    with Conformal Coat ♣ 
    ♣  Frame 10 & up only.

    e
    HIM
    Code Operator Interface
    0 Blank Cover
    3 Full Numeric LCD, Drive Mounted
    C Full Numeric LCD, Door Mount ⋆ 
    ⋆  IP21, NEMA Type 1 Frame 10 & up only.

    f
    Documentation
    Code Type
    A Manual

    g
    Brake
    Code w/Brake IGBT ‡ 
    Y Yes
    N No
    ‡  Brake IGBT is available on Frame 9 drives only.

    h
    Brake Resistor
    Code w/Resistor
    N No

    i
    Emission
    Code CE Filter CM Choke dv/dt Filter
    B Yes No No
    C ♦  No No Yes
    E ∆  Yes No Yes
    N §  No No No
    ♦ Frame 14 DC input drives only.
    ∆ Only available on Frame 14 AC input drives.
    § For use on ungrounded or resistive grounded distribution systems (Frame 9 drives only).

    j
    Comm Slot
    Code Version
    N None

    k
    I/O
    Code I/O Volts
    A 24V DC
    B 115V AC
    G 24V DC with Disable
    N None

    l
    Feedback
    Code Type
    0 None

    The catalog numbers listed below are for base drives in their respective power ratings. Click "Build a Catalog Number" to configure a drive for ordering. For detailed drive information, refer to the PowerFlex 700H Technical Data, publication 20C-TD001.

    IP21, NEMA Type 1

    380…480V AC, Three-Phase Drives with 24V DC I/O
    480V AC Input 400V AC Input Frame Size
    Output Amps ⋆  Normal Duty Hp Heavy Duty Hp Cat. No. ♣  Output Amps ⋆  Normal Duty kW Heavy Duty kW Cat. No. ♣ 
    Cont. 1 Min. 2 Sec. ‡  Cont. 1 Min. 2 Sec. ‡ 
    261 (205) 287 (308) 410 (410) 200 150 20CD261A0ANNBNA0 261 (205) 287 (308) 410 (410) 132 110 20CC261A0ANNBNA0 9
    300 (245) 330 (368) 450 (490) 250 200 20CD300A0ANNBNA0 300 (245) 330 (368) 450 (490) 160 132 20CC300A0ANNBNA0 9
    385 (300) 424 (450) 600 (600) 300 250 20CD385A0ANNBNA0 385 (300) 424 (450) 600 (600) 200 160 20CC385A0ANNBNA0 10
    460 (385) 506 (578) 770 (770) 350 300 20CD460A0ANNBNA0 460 (385) 506 (578) 770 (770) 250 200 20CC460A0ANNBNA0 10
    500 (420) 550 (630) 750 (840) 450 350 20CD500A0ANNBNA0 500 (420) 550 (630) 750 (840) 250 250 20CC500A0ANNBNA0 10
    590 (520) 649 (780) 956 (956) 500 450 20CD590A0ANNBNA0 590 (520) 649 (780) 956 (956) 315 250 20CC590A0ANNBNA0 11
    650 (590) 715 (885) 1062 (1062) 500 500 20CD650A0ANNBNA0 650 (590) 715 (885) 1062 (1062) 355 315 20CC650A0ANNBNA0 11
    730 (650) 803 (975) 1095 (1170) 600 500 20CD730A0ANNBNA0 730 (650) 803 (975) 1095 (1170) 400 355 20CC730A0ANNBNA0 11
    820 (730) 902 (1095) 1230 (1314) 700 600 20CD820A0ANNBNA0 820 (730) 902 (1095) 1230 (1314) 450 400 20CC820A0ANNBNA0 12
    920 (820) 1012 (1230) 1380 (1476) 800 700 20CD920A0ANNBNA0 920 (820) 1012 (1230) 1380 (1476) 500 450 20CC920A0ANNBNA0 12
    1030 (920) 1133 (1370) 1555 (1600) 900 800 20CD1K0A0ANNBNA0 1030 (920) 1133 (1370) 1555 (1600) 560 500 20CC1K0A0ANNBNA0 12
    1150 (1030) 1265 (1545) 1620 (1620) 1000 900 20CD1K1A0ANNBNA0 1150 (1030) 1265 (1545) 1620 (1620) 630 560 20CC1K1A0ANNBNA0 13
    1300 (1150) 1430 (1725) 2079 (2079) 1200 1000 20CD1K3A0ANNBNA0 1300 (1150) 1430 (1725) 2079 (2079) 710 630 20CC1K3A0ANNBNA0 13
    1450 (1200) 1595 (1800) 2175 (2400) 1250 1000 20CD1K4A0ANNBNA0 1450 (1200) 1595 (1800) 2175 (2400) 800 710 20CC1K4A0ANNBNA0 13
    1770 (1600) 1947 (2400) 2655 (2880) 1500 1400 20CD1K7A0ANNENA0 1770 (1600) 1947 (2400) 2655 (2880) 1000 900 20CC1K7A0ANNENA0 14
    2150 (1940) 2365 (2910) 3225 (3492) 1900 1700 20CD2K1A0ANNENA0 2150 (1940) 2365 (2910) 3225 (3492) 1200 1100 20CC2K1A0ANNENA0 14
    ⋆ These drives have dual current ratings; normal duty applications and heavy duty applications (in parenthesis). The drive may be operated at either rating.
    ‡ The 2 sec. output current is only available at initial start or drive operating at light load.
    ♣ Frames 10 & up include a Rittal enclosure.

    600…690V AC, Three-Phase Drives with 24V DC I/O
    600V AC Input 690V AC Input Frame Size
    Output Amps ⋆  Normal Duty Hp Heavy Duty Hp Cat. No. ♣  Output Amps ⋆  Normal Duty kW Heavy Duty kW Cat. No. ♣ 
    Cont. 1 Min. 2 Sec. ‡  Cont. 1 Min. 2 Sec. ‡ 
    170 (144) 187 (216) 245 (245) 150 150 20CE170A0ANNBNA0 170 (144) 187 (216) 245 (245) 160 132 20CF170A0ANNBNA0 9
    208 (170) 230 (250) 289 (289) 200 150 20CE208A0ANNBNA0 208 (170) 230 (250) 289 (289) 200 160 20CF208A0ANNBNA0 9
    261 (208) 287 (312) 375 (375) 250 200 20CE261A0ANNBNA0 261 (208) 287 (312) 375 (375) 250 200 20CF261A0ANNBNA0 10
    325 (261) 358 (392) 470 (470) 350 250 20CE325A0ANNBNA0 325 (261) 358 (392) 470 (470) 315 250 20CF325A0ANNBNA0 10
    385 (325) 424 (488) 585 (585) 400 350 20CE385A0ANNBNA0 385 (325) 424 (488) 585 (585) 355 315 20CF385A0ANNBNA0 10
    416 (325) 458 (488) 585 (585) 450 350 20CE416A0ANNBNA0 416 (325) 458 (488) 585 (585) 400 315 20CF416A0ANNBNA0 10
    460 (385) 506 (578) 693 (693) 500 400 20CE460A0ANNBNA0 460 (385) 506 (578) 693 (693) 450 355 20CF460A0ANNBNA0 11
    502 (460) 552 (690) 828 (828) 500 500 20CE502A0ANNBNA0 502 (460) 552 (690) 828 (828) 500 450 20CF502A0ANNBNA0 11
    590 (502) 649 (753) 885 (904) 600 500 20CE590A0ANNBNA0 590 (502) 649 (753) 885 (904) 560 500 20CF590A0ANNBNA0 11
    650 (590) 715 (885) 1062 (1062) 700 650 20CE650A0ANNBNA0 650 (590) 715 (885) 1062 (1062) 630 560 20CF650A0ANNBNA0 12
    750 (650) 825 (975) 1170 (1170) 800 700 20CE750A0ANNBNA0 750 (650) 825 (975) 1170 (1170) 710 630 20CF750A0ANNBNA0 12
    820 (750) 902 (975) 1170 (1170) 900 700 20CE820A0ANNBNA0 820 (750) 902 (975) 1170 (1170) 800 630 20CF820A0ANNBNA0 12
    920 (820) 1012 (1230) 1380 (1410) 1000 900 20CE920A0ANNBNA0 920 (820) 1012 (1230) 1380 (1410) 900 800 20CF920A0ANNBNA0 13
    1030 (920) 1133 (1380) 1545 (1755) 1100 1000 20CE1K0A0ANNBNA0 1030 (920) 1133 (1380) 1545 (1755) 1000 900 20CF1K0A0ANNBNA0 13
    1180 (1030) 1298 (1463) 1755 (1755) 1300 1100 20CE1K1A0ANNBNA0 1180 (1030) 1298 (1463) 1755 (1755) 1100 1000 20CF1K1A0ANNBNA0 13
    1500 (1300) 1650 (1950) 2250 (2340) 1600 1400 20CE1K5A0ANNENA0 1500 (1300) 1650 (1950) 2250 (2340) 1500 1300 20CF1K5A0ANNENA0 14
    1900 (1500) 2090 (2250) 2700 (2700) 2000 1600 20CE1K9A0ANNENA0 1900 (1500) 2090 (2250) 2700 (2700) 1900 1500 20CF1K9A0ANNENA0 14
    2250 (1900) 2475 (2782) 3335 (3335) 2400 2000 20CE2K2A0ANNENA0 2250 (1900) 2475 (2782) 3335 (3335) 2300 1900 20CF2K2A0ANNENA0 14
    ⋆ These drives have dual current ratings; normal duty applications and heavy duty applications (in parenthesis). The drive may be operated at either rating.
    ‡ The 2 sec. output current is only available at initial start or drive operating at light load.
    ♣ Frames 10 & up include a Rittal enclosure.

    IP20, NEMA Type 1, MCC

    380…480V AC, Three-Phase Drives with 24V DC I/O
    480V AC Input 400V AC Input Frame Size
    Output Amps ⋆  Normal Duty Hp Heavy Duty Hp Cat. No. Output Amps ⋆  Normal Duty kW Heavy Duty kW Cat. No.
    Cont. 1 Min. 2 Sec. ‡  Cont. 1 Min. 2 Sec. ‡ 
    385 (300) 424 (450) 600 (600) 300 250 20CD385B0ANNBNA0 385 (300) 424 (450) 600 (600) 200 160 20CD385B0ANNBNA0 10
    460 (385) 506 (578) 770 (770) 350 300 20CD460B0ANNBNA0 460 (385) 506 (578) 770 (770) 250 200 20CD460B0ANNBNA0 10
    500 (420) 550 (630) 750 (840) 450 350 20CD500B0ANNBNA0 500 (420) 550 (630) 750 (840) 250 250 20CD500B0ANNBNA0 10
    590 (520) 649 (780) 956 (956) 500 450 20CD590B0ANNBNA0 590 (520) 649 (780) 956 (956) 315 250 20CD590B0ANNBNA0 11
    650 (590) 715 (885) 1062 (1062) 500 500 20CD650B0ANNBNA0 650 (590) 715 (885) 1062 (1062) 355 315 20CD650B0ANNBNA0 11
    730 (650) 803 (975) 1095 (1170) 600 500 20CD730B0ANNBNA0 730 (650) 803 (975) 1095 (1170) 400 355 20CD730B0ANNBNA0 11
    820 (730) 902 (1095) 1230 (1314) 700 600 20CD820B0ANNBNA0 820 (730) 902 (1095) 1230 (1314) 450 400 20CD820B0ANNBNA0 12
    920 (820) 1012 (1230) 1380 (1476) 800 700 20CD920B0ANNBNA0 920 (820) 1012 (1230) 1380 (1476) 500 450 20CD920B0ANNBNA0 12
    1030 (920) 1133 (1370) 1555 (1600) 900 800 20CD1K0B0ANNBNA0 1030 (920) 1133 (1370) 1555 (1600) 560 500 20CD1K0B0ANNBNA0 12
    ⋆ These drives have dual current ratings; normal duty applications and heavy duty applications (in parenthesis). The drive may be operated at either rating.
    ‡ The 2 sec. output current is only available at initial start or drive operating at light load.

    600V AC, Three-Phase Drives with 24V DC I/O
    600V AC Input Frame Size
    Output Amps ⋆  Normal Duty Hp Heavy Duty Hp Cat. No.
    Cont. 1 Min. 2 Sec. ‡ 
    261 (208) 287 (312) 375 (375) 250 200 20CE261B0ANNBNA0 10
    325 (261) 358 (392) 470 (470) 350 250 20CE325B0ANNBNA0 10
    385 (325) 424 (488) 585 (585) 400 350 20CE385B0ANNBNA0 10
    416 (325) 458 (488) 585 (585) 450 350 20CE416B0ANNBNA0 10
    460 (385) 506 (578) 693 (693) 500 400 20CE460B0ANNBNA0 11
    502 (460) 552 (690) 828 (828) 500 500 20CE502B0ANNBNA0 11
    590 (502) 649 (753) 885 (904) 600 500 20CE590B0ANNBNA0 11
    650 (590) 715 (885) 1062 (1062) 700 650 20CE650B0ANNBNA0 12
    750 (650) 825 (975) 1170 (1170) 800 700 20CE750B0ANNBNA0 12
    820 (750) 902 (975) 1170 (1170) 900 700 20CE820B0ANNBNA0 12
    ⋆ These drives have dual current ratings; normal duty applications and heavy duty applications (in parenthesis). The drive may be operated at either rating.
    ‡ The 2 sec. output current is only available at initial start or drive operating at light load.

    IP54, NEMA Type 12, Rittal

    380…480V AC, Three-Phase Drives with 24V DC I/O
    480V AC Input 400V AC Input Frame Size
    Output Amps ⋆  Normal Duty Hp Heavy Duty Hp Cat. No. Output Amps ⋆  Normal Duty kW Heavy Duty kW Cat. No.
    Cont. 1 Min. 2 Sec. ‡  Cont. 1 Min. 2 Sec. ‡ 
    385 (300) 424 (450) 600 (600) 300 250 20CD385H0ANNBNA0 385 (300) 424 (450) 600 (600) 200 160 20CC385H0ANNBNA0 10
    460 (385) 506 (578) 770 (770) 350 300 20CD460H0ANNBNA0 460 (385) 506 (578) 770 (770) 250 200 20CC460H0ANNBNA0 10
    500 (420) 550 (630) 750 (840) 450 350 20CD500H0ANNBNA0 500 (420) 550 (630) 750 (840) 250 250 20CC500H0ANNBNA0 10
    590 (520) 649 (780) 956 (956) 500 450 20CD590H0ANNBNA0 590 (520) 649 (780) 956 (956) 315 250 20CC590H0ANNBNA0 11
    650 (590) 715 (885) 1062 (1062) 500 500 20CD650H0ANNBNA0 650 (590) 715 (885) 1062 (1062) 355 315 20CC650H0ANNBNA0 11
    730 (650) 803 (975) 1095 (1170) 600 500 20CD730H0ANNBNA0 730 (650) 803 (975) 1095 (1170) 400 355 20CC730H0ANNBNA0 11
    820 (730) 902 (1095) 1230 (1314) 700 600 20CD820H0ANNBNA0 820 (730) 902 (1095) 1230 (1314) 450 400 20CC820H0ANNBNA0 12
    920 (820) 1012 (1230) 1380 (1476) 800 700 20CD920H0ANNBNA0 920 (820) 1012 (1230) 1380 (1476) 500 450 20CC920H0ANNBNA0 12
    1030 (920) 1133 (1370) 1555 (1600) 900 800 20CD1K0H0ANNBNA0 1030 (920) 1133 (1370) 1555 (1600) 560 500 20CC1K0H0ANNBNA0 12
    1150 (1030) 1265 (1545) 1620 (1620) 1000 900 20CD1K1H0ANNBNA0 1150 (1030) 1265 (1545) 1620 (1620) 630 560 20CC1K1H0ANNBNA0 13
    1300 (1150) 1430 (1725) 2079 (2079) 1200 1000 20CD1K3H0ANNBNA0 1300 (1150) 1430 (1725) 2079 (2079) 710 630 20CC1K3H0ANNBNA0 13
    1450 (1200) 1595 (1800) 2175 (2400) 1250 1000 20CD1K4H0ANNBNA0 1450 (1200) 1595 (1800) 2175 (2400) 800 710 20CC1K4H0ANNBNA0 13
    1770 (1600) 1947 (2400) 2655 (2880) 1500 1400 20CD1K7H0ANNENA0 1770 (1600) 1947 (2400) 2655 (2880) 1000 900 20CC1K7H0ANNENA0 14
    2150 (1940) 2365 (2910) 3225 (3492) 1900 1700 20CD2K1H0ANNENA0 2150 (1940) 2365 (2910) 3225 (3492) 1200 1100 20CC2K1H0ANNENA0 14
    ⋆ These drives have dual current ratings; normal duty applications and heavy duty applications (in parenthesis). The drive may be operated at either rating.
    ‡ The 2 sec. output current is only available at initial start or drive operating at light load.

    600…690V AC, Three-Phase Drives with 24V DC I/O
    600V AC Input 690V AC Input Frame Size
    Output Amps ⋆  Normal Duty Hp Heavy Duty Hp Cat. No. Output Amps ⋆  Normal Duty kW Heavy Duty kW Cat. No.
    Cont. 1 Min. 2 Sec. ‡  Cont. 1 Min. 2 Sec. ‡ 
    261 (208) 287 (312) 375 (375) 250 200 20CE261H0ANNBNA0 261 (208) 287 (312) 375 (375) 250 200 20CF261H0ANNBNA0 10
    325 (261) 358 (392) 470 (470) 350 250 20CE325H0ANNBNA0 325 (261) 358 (392) 470 (470) 315 250 20CF325H0ANNBNA0 10
    385 (325) 424 (488) 585 (585) 400 350 20CE385H0ANNBNA0 385 (325) 424 (488) 585 (585) 355 315 20CF385H0ANNBNA0 10
    416 (325) 458 (488) 585 (585) 450 350 20CE416H0ANNBNA0 416 (325) 458 (488) 585 (585) 400 315 20CF416H0ANNBNA0 10
    460 (385) 506 (578) 693 (693) 500 400 20CE460H0ANNBNA0 460 (385) 506 (578) 693 (693) 450 355 20CF460H0ANNBNA0 11
    502 (460) 552 (690) 828 (828) 500 500 20CE502H0ANNBNA0 502 (460) 552 (690) 828 (828) 500 450 20CF502H0ANNBNA0 11
    590 (502) 649 (753) 885 (904) 600 500 20CE590H0ANNBNA0 590 (502) 649 (753) 885 (904) 560 500 20CF590H0ANNBNA0 11
    650 (590) 715 (885) 1062 (1062) 700 650 20CE650H0ANNBNA0 650 (590) 715 (885) 1062 (1062) 630 560 20CF650H0ANNBNA0 12
    750 (650) 825 (975) 1170 (1170) 800 700 20CE750H0ANNBNA0 750 (650) 825 (975) 1170 (1170) 710 630 20CF750H0ANNBNA0 12
    820 (750) 902 (975) 1170 (1170) 900 700 20CE820H0ANNBNA0 820 (750) 902 (975) 1170 (1170) 800 630 20CF820H0ANNBNA0 12
    920 (820) 1012 (1230) 1380 (1410) 1000 900 20CE920H0ANNBNA0 920 (820) 1012 (1230) 1380 (1410) 900 800 20CF920H0ANNBNA0 13
    1030 (920) 1133 (1380) 1545 (1755) 1100 1000 20CE1K0H0ANNBNA0 1030 (920) 1133 (1380) 1545 (1755) 1000 900 20CF1K0H0ANNBNA0 13
    1180 (1030) 1298 (1463) 1755 (1755) 1300 1100 20CE1K1H0ANNBNA0 1180 (1030) 1298 (1463) 1755 (1755) 1100 1000 20CF1K1H0ANNBNA0 13
    1500 (1300) 1650 (1950) 2250 (2340) 1600 1400 20CE1K5H0ANNENA0 1500 (1300) 1650 (1950) 2250 (2340) 1500 1300 20CF1K5H0ANNENA0 14
    1900 (1500) 2090 (2250) 2700 (2700) 2000 1600 20CE1K9H0ANNENA0 1900 (1500) 2090 (2250) 2700 (2700) 1900 1500 20CF1K9H0ANNENA0 14
    2250 (1900) 2475 (2782) 3335 (3335) 2400 2000 20CE2K2H0ANNENA0 2250 (1900) 2475 (2782) 3335 (3335) 2300 1900 20CF2K2H0ANNENA0 14
    ⋆ These drives have dual current ratings; normal duty applications and heavy duty applications (in parenthesis). The drive may be operated at either rating.
    ‡ The 2 sec. output current is only available at initial start or drive operating at light load.

    Human Interface Modules
                 
    Click to enlarge - 20him_blank Click to enlarge - 20him_a3 Click to enlarge - 20him_a5 Click to enlarge - 20him_a6 Click to enlarge - 20him_c3s Click to enlarge - 20him_c5s Click to enlarge - 20him_c6s
    Blank Plate 20-HIM-A3 20-HIM-A5 20-HIM-A6 20-HIM-C3S 20-HIM-C5S 20-HIM-C6S

    Human Interface Modules
    Description Cat. No. Used with PowerFlex Drive
    70 700 700H 700S 700L 753/755
    No HIM (Blank Plate), Handheld/Local (Drive Mount) 20-HIM-A0 ü ü ü ü ü ü
    LCD Display, Full Numeric Keypad, Handheld/Local (Drive Mount) 20-HIM-A3 ü ü ü ü ü  
    LCD Display, Programmer Only, Handheld/Local (Drive Mount) 20-HIM-A5 ü ü ü ü ü  
    Enhanced, LCD, Full Numeric Keypad, Handheld/Local (Drive Mount) 20-HIM-A6 ü ü ü ü ü ü § 
    Remote (Panel Mount) LCD Display, Full Numeric Keypad ⋆ ‡  20-HIM-C3S ü ü ü ü ü  
    Remote (Panel Mount) LCD Display, Programmer Only ⋆ ‡  20-HIM-C5S ü ü ü ü ü  
    Enhanced, LCD, Full Numeric Keypad ⋆ ‡  20-HIM-C6S ü ü ü ü ü ü ♦ 
    ⋆ IP66, NEMA Type 4X/12 - For indoor use only.
    ‡ Includes a 1202-C30 interface cable (3 meters) for connection to drive.
    § Select for Frames 2…5 IP54, NEMA/UL Type 12 drives.
    ♦ Select for Frames 6…7 IP54, NEMA/UL Type 12 drives.

    Human Interface Module Accessories
    Description Cat. No. Used with PowerFlex Drive
    70 700 700H 700S 700L 753/755
    Bezel Kit for LCD HIMs, NEMA Type 1 ‡  20-HIM-B1 ü ü ü ü ü ü
    PowerFlex HIM Interface Cable, 1 m (39 in) ♣  20-HIM-H10 ü ü ü ü ü ü
    Comm Option Cable Kit (Male-Male)              
    0.33 Meters (1.1 Feet) 1202-C03 ü ü ü ü ü ü
    1 Meter (3.3 Feet) 1202-C10 ü ü ü ü ü ü
    3 Meter (9.8 Feet) 1202-C30 ü ü ü ü ü ü
    9 Meter (29.5 Feet) 1202-C90 ü ü ü ü ü ü
    Cable Kit (Male-Female) ∆               
    0.33 Meters (1.1 Feet) 1202-H03 ü ü ü ü ü ü
    1 Meter (3.3 Feet) 1202-H10 ü ü ü ü ü ü
    3 Meter (9.8 Feet) 1202-H30 ü ü ü ü ü ü
    9 Meter (29.5 Feet) 1202-H90 ü ü ü ü ü ü
    DPI™ Cable Kit with Connectors, Tools and 100 m (328 ft) Cable 1202-CBL-KIT-100M ü ü ü ü ü ü
    DPI Cable Connector Kit 1202-TB-KIT-SET ü ü ü ü ü ü
    DPI/SCANport™ One to Two Port Splitter Cable 1203-S03 ü ü ü ü ü ü
    ‡ Includes a 1202-C30 interface cable (3 meters) for connection to drive.
    ♣ Required only when HIM is used as handheld or remote.
    ∆ Required in addition to 20-HIM-H10 for distances up to a total maximum of 10 Meters (32.8 Feet).

    Communication Option Kits
    Description Cat. No. Used with PowerFlex Drive
    70 700 700H 700S 700L 753/755
    BACnet/IP Option Module 20-750-BNETIP           ü
    BACnet® MS/TP RS485 Communication Adapter 20-COMM-B ü ü ü      
    Coaxial ControlNet™ Option Module 20-750-CNETC           ü
    ControlNet™ Communication Adapter (Coax) 20-COMM-C ü ü ü ü ü ü § 
    ControlNet™ Communication Adapter (Coax) Conformal Coat 20-COMM-C-MX3 ü ü ü ü ü ü § 
    DeviceNet™ Option Module 20-750-DNET           ü
    DeviceNet™ Communication Adapter 20-COMM-D ü ü ü ü ü ü § 
    DeviceNet™ Communication Adapter Conformal Coat 20-COMM-D-MX3 ü ü ü ü ü ü § 
    Dual-port EtherNet/IP Option Module 20-750-ENETR           ü
    EtherNet/IP™ Communication Adapter 20-COMM-E ü ü ü ü ü ü § 
    EtherNet/IP™ Communication Adapter Conformal Coat 20-COMM-E-MX3 ü ü ü ü ü ü § 
    HVAC Communication Adapter 20-COMM-H ü ü ü ü ♠  ü ü § 
    CANopen® Communication Adapter 20-COMM-K ü ü ü ü ü ü § 
    LonWorks® Communication Adapter 20-COMM-L ü ü ü     ü § 
    Modbus/TCP Communication Adapter 20-COMM-M ü ü ü ü ü ü § 
    Profibus DPV1 Option Module 20-750-PBUS           ü
    Single-port Profinet IO Option Module 20-750-PNET           ü ♣ 
    Dual-port Profinet IO Option Module 20-750-PNET2P           ü ♣ 
    PROFIBUS™ DP Communication Adapter 20-COMM-P ü ü ü ü ü ü § 
    ControlNet™ Communication Adapter (Fiber) 20-COMM-Q ü ü ü ü ü ü § & 
    Remote I/O Communication Adapter ∆  20-COMM-R ü ü ü ü ü ü § 
    Remote I/O Communication Adapter Conformal Coat ∆  20-COMM-R-MX3 ü ü ü ü ü ü § 
    RS485 DF1 Communication Adapter 20-COMM-S ü ü ü ü ü ü § 
    RS485 DF1 Communication Adapter Conformal Coat 20-COMM-S-MX3 ü ü ü ü ü ü § 
    External Communications Kit Power Supply 20-XCOMM-AC-PS1 ü ü ü ü ü ü
    DPI External Communications Kit 20-XCOMM-DC-BASE ü ü ü ü ü ü
    External DPI I/O Option Board ♦  20-XCOMM-IO-OPT1 ü ü ü ü ü ü
    PowerFlex Compact I/O to DPI/SCANport Module 1769-SM1 ü ü ü ü ü ü
    DriveLogix ControlNet Communication Adapter (Coax) ‡  1788-CNC       ü ü ▶   
    DriveLogix Comm Option, ControlNet Redundant (Coax) ‡  1788-CNCR       ü ü ▶   
    DriveLogix Comm Option, ControlNet (Fiber) ‡  1788-CNF       ü ü ▶   
    DriveLogix Comm Option, ControlNet Redundant (Fiber) ‡  1788-CNFR       ü ü ▶   
    DriveLogix Comm Option, DeviceNet (Open Conn.) ‡  1788-DNBO       ü ü ▶   
    DriveLogix Comm Option, EtherNet/IP (Twisted Pair) ‡  1788-ENBT       ü ü ▶   
    DriveLogix5730 Comm Option, Embedded EtherNet/IP 20D-DL2-ENET0       ü ü ▶   
    ♦ For use only with DPI External Communications Kits 20-XCOMM-DC-BASE.
    ♠ Only Modbus RTU can be used.
    ‡ For use with DriveLogix option only. Requires Logix Expansion Board (20D-DL2-LEB0).
    § Requires a Communication Carrier Card (20-750-20COMM or 20-750-20COMM-F1). Refer to PowerFlex 750-Series Legacy Communication Compatibility for compatibility details.
    ▶ When using a PowerFlex 700S control.
    ∆ This item has Silver Series status. For information, refer to http://www.ab.com/silver.
    & Not supported in Frame 1.
    ♣ Contact your local Rockwell Automation sales office or Allen-Bradley distributor for availability.

    Communication Accessories
    Description Cat. No. Used with PowerFlex Drive
    70 700 700H 700S 700L 753/755
    Serial Null Modem Adapter 1203-SNM ü ü ü ü ü ü
    Smart Self-powered Serial Converter (RS232) includes 1203-SFC and 1202-C10 Cables 1203-SSS ü ü ü ü ü ü
    Universal Serial Bus™ (USB) Converter includes 2m USB, 20-HIM-H10 & 22-HIM-H10 Cables 1203-USB ü ü ü ü ü ü
    ControlNet T-tap right angle 1786-TPR       ü ü ü
    Communication Carrier Card for PowerFlex 750-Series Frame 1 drives 20-750-20COMM-F1           ü
    Communication Carrier Card for PowerFlex 750-Series Frame 2 or higher drives 20-750-20COMM           ü
      

    PowerFlex 750-Series Legacy Communication Compatibility

    Most legacy communication adapters (20-COMM) can be used with the PowerFlex 753/755. However, the restrictions stated below do apply.

    Frame 1 - It is recommended that the 20-750-20COMM-F1 Communication Carrier Card only be installed in Port 4. Port 5 will not be accessible when this module is installed.

    Frames 2 and larger - It is recommended that the 20-750-20COMM Communication Carrier Card be installed in Port 6. Using Port 4 or 5 will make the adjacent left port inaccessible to other option modules and may interfere with network cable connections.


    Adapter Accesses Ports 2, 3 and 6
    for I/O Connections
    (Implicit & Explicit Messaging)
    Accesses Port 7…14 Devices Supports Drive Add On Profiles Supports Asian-Languages ♦ 
    20-COMM-B Not Compatible
    20-COMM-C ü‡  ü v3.001 ♣  ü ∆  ü v3.001 ♣ 
    20-COMM-D Not Compatible
    20-COMM-E ü v4.001 ♣  ü ∆  ü v4.001 ♣ 
    20-COMM-H ü v2.009 §  Not Compatible
    20-COMM-K ü v1.001 ♣ 
    20-COMM-L ü v1.007 ♣ 
    20-COMM-M ü‡  ü v2.001 ♣  Not Compatible ü v2.001 ♣ 
    20-COMM-Q ü‡  ü v3.001 ♣  ü ∆  ü v3.001 ♣ 
    20-COMM-R Not Compatible
    20-COMM-S
    ‡ Controller must be capable of reading/writing 32-bit floating point (REAL) values.
    § Supports all three modes of operation (RTU, P1, N2).
    ♣ Requires this adapter firmware version or higher.
    ∆ Requires firmware version v1.05 or higher of the drive Add On Profiles for RSLogix 5000 version v16 or higher.
    ♦ Chinese, Japanese, and Korean languages are supported at the time of publication.

    Feedback Options
    Description Cat. No. Used with PowerFlex Drive
    70 700 700H 700S 700L 753/755
    5V/12V Encoder &  20A-ENC-1 ü          
    12V/5V Encoder 20B-ENC-1   ü     ü  
    12V/5V Encoder with Conformal Coat 20B-ENC-1-MX3   ü        
    Multi-Device Interface ♦  20D-MDI-C2       ü ü ▶   
    2nd Encoder, 5V/12V ♦  20D-P2-ENC0       ü ü ▶   
    Resolver ♦  20D-RES-A1       ü ü ▶   
    Stegmann High Resolution Hyperface Encoder ♦  20D-STEG-B1       ü ü ▶   
    Heidenhain High Resolution EnDat Encoder 20D-HEID-D0       ü ü ▶   
    Incremental Encoder 20-750-ENC-1           ü ♠ 
    Dual Incremental Encoder 20-750-DENC-1           ü ♠ 
    Universal Feedback (includes Stegmann, Heidenhain, SSI, Biss, 5V Incremental) 20-750-UFB-1           ü ⋆ 
    & Works only with PowerFlex 70 Enhanced Control.
    ♦ Requires Expanded Cassette
    # When using a PowerFlex 700 with Vector Control.
    ⋆ PowerFlex 755 only.
    ▶ When using a PowerFlex 700S control.
    ♠ Homing and registration functions are not supported when using this device with RSLogix 5000 embedded motion instructions. To use these functions, the Universal Feedback Board (20-750-UFB-1) must be used.

    I/O Option Kits
    Description Cat. No. Used with PowerFlex Drive
    70 700 700H 700S 700L 753/755
    24V DC Digital Inputs (6) w/Analog I/O (4), Slot A ♠  20C-DA1-A     ü      
    115V AC Digital Inputs (6) w/Analog I/O (4), Slot A ♠  20C-DA1-B     ü      
    115V AC Digital Outputs (3), Slot B ♠  20C-DO1     ü      
    24V DC I/O with 2 Analog In, 2 Analog Out, 6 Digital In and 2 Relay Outputs 20-750-2262C-2R           ü § 
    115V AC I/O with 2 Analog In, 2 Analog Out, 6 Digital In and 2 Relay Outputs 20-750-2262D-2R           ü § 
    24V DC I/O with 2 Analog In, 2 Analog Out, 6 Digital In, 3 Digital Out, 1 Relay & 2 Transistor Outputs 20-750-2263C-1R2T           ü § 
    ♠ Only one card allowed per slot.
    § I/O option kits are not allowed in CIP motion mode.

    Safety Options
    Description Cat. No. Used with PowerFlex Drive
    70 700 700H 700S 700L 753/755
    DriveGuard Safe Torque-Off 20A-DG01 ü          
    DriveGuard Safe Torque-Off w/2nd Encoder 20D-P2-DG01       ü ü ▶   
    Safe Torque-Off (ATEX capable) ♠  20C-DG1     ü      
    Safe Torque-Off 20-750-S           ü ⋆ 
    Safe Speed Monitor 20-750-S1           ü ⋆ ‡ 
    ♠ Only one card allowed per slot.
    ▶ When using PowerFlex 700S control. This option kit cannot be used on Frame 2 drives, however it is available as a factory installed option.
    ‡ Requires the Dual Incremental Encoder or Universal Feedback Option. Also requires the 20-750-EMCSSM1-F8 EMC Option Kit with Frame 8…9 drives.
    ⋆ Drive can accomodate only one option.

    PowerFlex 700 Control Option Kits
    Control with I/O Factory Installed
    Cat. Code # 
    Cat. No. Used with PowerFlex Drive
    70 700 700H 700S 700L 753/755
    Vector Control - 24V DC with: ▶ 
    60 Hz Maximum NNAD 20B-VECT-C0AD   ü        
    82 Hz Maximum NNAX 20B-VECTB-C0AX   ü        
    Cascading Fan/Pump Control NNAE 20B-VECT-C0AE   ü        
    Pump Off (for Pump Jack) NNBA 20B-VECTB-C0BA   ü        
    Vector Control - 24V DC, Conformal Coat ▶  20B-VECTB-C0-MX3   ü        
    Vector Control - 115V AC ▶  D &  20B-VECTB-D0   ü        
    Vector Control - 115V AC with: ▶ 
    60 Hz Maximum NNAD 20B-VECT-D0AD   ü        
    82 Hz Maximum NNAX 20B-VECTB-D0AX   ü        
    Cascading Fan/Pump Control NNAE 20B-VECT-D0AE   ü        
    Pump Off (for Pump Jack) NNBA 20B-VECT-D0BA   ü        
    Vector Control - 115V AC, Conformal Coat ▶  20B-VECTB-D0-MX3   ü        
    ▶ Vector Control option utilizes DPI Only.
    # This code is entered at the end of the drive catalog number (positions 17…20).
    & This code is entered at position 15 of the drive catalog number.

    PowerFlex 750-Series Option Kits
    Description Frame Cat. No. Used with PowerFlex Drive
    70 700 700H 700S 700L 753/755
    Auxiliary Power Supply 24V Aux Power Supply 2…7 ∆  20-750-APS           ü
    DC Bus Bar Option Kit DC Bus Bars, 380…480V AC drives 6 20-750-DCBB1-F6           ü
    7 20-750-DCBB1-F7           ü
    DC Bus Connection Kit Allows connection of the drive DC bus terminals to the bus rails at the back of the cabinet. 8…10 20-750-BUS1-F8           ü
    EMC Option Kit EMC Plate with Core 1 20-750-EMC1-F1           ü
    2 20-750-EMC1-F2           ü
    3 20-750-EMC1-F3           ü
    EMC Plate with Cores 4 20-750-EMC1-F4           ü
    5 20-750-EMC1-F5           ü
    EMC Core 1 20-750-EMC2-F1           ü
    2 20-750-EMC2-F2           ü
    3 20-750-EMC2-F3           ü
    EMC Cores 4…5 20-750-EMC2-F45           ü
    EMC Core – Inverter-mounted output, for AC Input and DC Input drives. 8…10 20-750-EMCCM1-F8           ü
    EMC Core – Cabinet-mounted input, for Common DC Input drives only. 8…10 20-750-CBPEMCCM1-F8           ü
    EMC Core – Cabinet-mounted input, for AC Input drives only. 8…10 20-750-EMCCM1-F9           ü
    EMC Cores – Required when using the Safe Speed Monitor option 20-750-S1. 8…10 20-750-EMCSSM1-F8           ü
    Door Shielding Kit 8…10 20-750-EMCDK1-F10           ü
    Flange Adapter Kit Converts Open Type drive to external heatsink (flange) with NEMA/UL Type 1 integrity backside. §  2 20-750-FLNG1-F2           ü
    3 20-750-FLNG1-F3           ü
    4 20-750-FLNG1-F4           ü
    5 20-750-FLNG1-F5           ü
    Converts Open Type drive to external heatsink (flange) with NEMA/UL Type 4X/12 integrity backside. 6 20-750-FLNG4-F6           ü
    7 20-750-FLNG4-F7           ü
    L Bus Bar Kit Includes three L-brackets 8…10 20-750-LBRKT1           ü
    NEMA/UL Type 1 Option Kit NEMA/UL Type 1 Kit 1 20-750-NEMA1-F1           ü
    2 20-750-NEMA1-F2           ü
    3 20-750-NEMA1-F3           ü
    4 20-750-NEMA1-F4           ü
    5 20-750-NEMA1-F5           ü
    6 20-750-NEMA1-F6           ü
    7 20-750-NEMA1-F7           ü
    Power Terminal Extension Allows connection of two parallel leads to the AC power terminals. 6 20-750-ACTE1-F6           ü
    Power Terminal Guard Provides additional ingress protection on power terminals. 6 20-750-PTG1-F6           ü
    7 20-750-PTG1-F7           ü
    Remote Control POD Mounting Kit Mounting hardware with 25 m (75 ft) fiber optic and 24V control cables for mounting the control POD in a cabinet that is separate from the drive. 8…10 20-750-RPD1-F8           ü
    Roll-Out Cart ♣  Provides a means to move the power core and allow access to the power terminals. 8…10 20-750-CART1-F8           ü
    ∆ Frame 8 and up drives can be powered from an external 24V DC source, a 20-750-APS is not required.
    § This kit is for use with IP20, NEMA/UL Type 0 drives and will not provide an air-tight or water-tight seal. Where sealing is required (e.g. contaminated, dirty or wet environments), a drive with an “F” enclosure option must be used.
    ♣ Required for Frame 8 and up drives to assist with power wiring.

    Other Options
    Description Cat. No. Used with PowerFlex Drive
    70 700 700H 700S 700L 753/755
    115V AC Interface AK-M9-115VAC-1 ü          
    Frame E Flange Gasket AK-M9-GASKET1-E4 ü          
    Service Connection Board ⋆  SK-M9-SCB1 ü          
    Removable I/O Terminal Block SK-G9-TB1-S1   ü        
    Removable Encoder Terminal Block SK-G9-TB1-ENC1   ü        
    Touch Cover - Converts IP00/Open Type drive to IP20/NEMA/UL Type 1. No wiring space provided. 20-OPT-TC     ü      
    Top Hat - Converts IP00/Open Type drive to IP20/NEMA/UL Type 1. Allows for wiring space. 20-OPT-TH     ü      
    Auxiliary Control Power Supply 20-24V-AUX1       ü    
    PowerFlex 700S Phase II Control with Expanded Cassette 20D-P2-CKE1       ü ü ▶   
    PowerFlex 700S Phase II Control with Slim Cassette 20D-P2-CKS1       ü    
    PowerFlex 700S DriveLogix5730 Phase II Control with Expanded Cassette 20D-DL2-CKE1       ü ü ▶   
    PowerFlex 700S DriveLogix5730 Phase II Control with Slim Cassette 20D-DL2-CKS1       ü    
    ⋆ Provides temporary DPI/HIM connection for NEMA/UL Type 1 and Flange drives with cover removed.
    ▶ When using PowerFlex 700S control and Expanded Cassette.

    SynchLink Accessories
    Description ⋆  Cat. No. Used with PowerFlex Drive
    70 700 700H 700S 700L 753/755
    SynchLink Board 20D-P2-SLB0       ü ü ▶   
    SynchLink Fiber Base Block 1751-SLBA       ü ü ▶   
    SynchLink 4-port Fiber Splitter Block 1751-SL4SP       ü ü ▶   
    SynchLink Fiber Bypass Switch Block 1751-SLBP       ü ü ▶   
    2x3 Meter Fiber Link for Power Monitor/SynchLink 1403-CF003       ü ü ▶   
    2x5 Meter Fiber Link for Power Monitor/SynchLink 1403-CF005       ü ü ▶   
    10 Meter Fiber Link for Power Monitor/SynchLink 1403-CF010       ü ü ▶   
    ⋆ Refer to publication number 1769-SG001 for details on SynchLink.
    ▶ When using PowerFlex 700S control.

    DriveLogix Option Kits
    Description Cat. No. Used with PowerFlex Drive
    70 700 700H 700S 700L 753/755
    Logix Expansion board for DriveLogix5730 ♦  20D-DL2-LEB0       ü ü ▶   
    Industrial Compact Flash 64 MB Memory Card for DriveLogix5730 1784-CF64       ü ü ▶   
    ♦ Requires Expanded Cassette.
    ▶ When using PowerFlex 700S control.

    DriveLogix I/O Cables
    Description Cat. No. Used with PowerFlex Drive
    70 700 700H 700S 700L 753/755
    DriveLogix5730 - Compact I/O cable, 3.28 ft. (1 meter), Left Bus Cap♦ ♣  20D-DL2-CL3       ü ü ▶   
    DriveLogix5730 - Compact I/O cable, 3.28 ft. (1 meter), Right Bus Cap ♦ ♣  20D-DL2-CR3       ü ü ▶   
    Logix5000 RS-232 Programming Cable 1756-CP3       ü ü ▶   
    ♦ Requires Expanded Cassette.
    ♣ Refer to Publication 1769-SG001 for details and selection of Compact I/O.
    ▶ When using PowerFlex 700S control.

    PowerFlex 70 Small Duty Internal Dynamic Brake Resistors

    Limited duty resistors mount directly to the back surface of the drive and require no extra panel space. Internal resistors are non-destructive and do not require a resistor overheat external safety circuit.

    PowerFlex 70 AC Drive Small Duty Internal DB Resistor
    Normal Duty⋆ 
    kW (Hp)
    Heavy Duty⋆ 
    kW (Hp)
    Min DB Res
    Ohms ±10%
    Cat. No. Resistance‡ 
    Ohms ±5%
    Continuous Power
    kW
    Max Energy
    kJ
    Max Braking Torque
    % of ND Motor
    Application Type 1 Application Type 2
    Braking Torque
    % of ND Motor
    Duty Cycle Braking Torque
    % of ND Motor
    Duty Cycle
    200…240 Volt AC Input Drives
    0.37 (0.5) 0.25 (0.33) 33 20AB-DB1-A 62 0.048 8.3 307% 100% 25.9% 150% 17.3%
    0.75 (1.0) 0.55 (0.75) 33 20AB-DB1-A 62 0.048 7.3 300% 100% 12.8% 150% 8.5%
    1.5 (2.0) 1.1 (1.5) 33 20AB-DB1-B 62 0.028 0.8 160% 100% 3.7% 150% 2.5%
    2.2 (3.0) 1.5 (2.0) 33 20AB-DB1-B 62 0.028 0.8 109% 100% 2.5% 109% 2.3%
    4.0 (5.0) 3.0 (3.0) 30 20AB-DB1-C 62 0.040 0.8 60% 60% 3.3% N/A N/A
    5.5 (7.5) 4.0 (5.0) 21 20AB-DB1-D 22 0.036 0.9 117% 100% 1.3% 117% 1.1%
    7.5 (10) 5.5 (7.5) 21 20AB-DB1-D 22 0.036 0.9 86% 86% 1.1% N/A N/A
    400…480 Volt AC Input Drives
    0.37 (0.5) 0.25 (0.33) 68 20AD-DB1-A 115 0.048 8.3 320% 100% 25.9% 150% 17.3%
    0.75 (1.0) 0.55 (0.75) 68 20AD-DB1-A 115 0.048 9.0 259% 100% 12.8% 150% 8.5%
    1.5 (2.0) 1.1 (1.5) 68 20AD-DB1-A 115 0.048 2.4 243% 100% 6.4% 150% 4.3%
    2.2 (3.0) 1.5 (2.0) 68 20AD-DB1-B 115 0.028 0.9 206% 100% 2.5% 150% 1.7%
    4.0 (5.0) 3.0 (3.0) 68 20AD-DB1-B 115 0.028 0.9 129% 100% 1.4% 129% 1.1%
    5.5 (7.5) 4.0 (5.0) 74 20AD-DB1-C 115 0.04 0.9 94% 94% 1.5% N/A N/A
    7.5 (10) 5.5 (7.5) 74 20AD-DB1-C 115 0.04 0.9 69% 69% 1.5% N/A N/A
    11 (15) 7.5 (10) 44 20AD-DB1-D 62 0.036 0.8 87% 87% 0.8% N/A N/A
    15 (20) 11 (15) 31 20AD-DB1-D 62 0.036 0.8 64% 64% 0.8% N/A N/A
    500…600 Volt AC Input Drives
    0.37 (0.5) 0.25 (0.33) 117 20AD-DB1-A 115 0.048 8.3 287% 100% 25.9% 150% 17.3%
    0.75 (1.0) 0.55 (0.75) 117 20AD-DB1-A 115 0.048 9.0 263% 100% 12.8% 150% 8.5%
    1.5 (2.0) 1.1 (1.5) 117 20AD-DB1-A 115 0.048 2.4 243% 100% 6.4% 150% 4.3%
    2.2 (3.0) 1.5 (2.0) 117 20AD-DB1-B 115 0.028 0.9 202% 100% 2.5% 150% 1.7%
    4.0 (5.0) 3.0 (3.0) 80 20AD-DB1-B 115 0.028 0.9 193% 100% 1.4% 150% 0.9%
    5.5 (7.5) 4.0 (5.0) 80 20AD-DB1-C 115 0.04 0.9 147% 100% 1.5% 147% 1.0%
    7.5 (10) 5.5 (7.5) 80 20AD-DB1-C 115 0.04 0.9 108% 100% 1.1% 108% 1.0%
    11 (15) 7.5 (10) 48 N/A N/A N/A N/A N/A N/A N/A N/A N/A
    15 (20) 11 (15) 48 N/A N/A N/A N/A N/A N/A N/A N/A N/A
    ⋆ Duty cycle listed is based on full speed to zero speed deceleration. For constant regen at full speed, duty cycle capability is half of what is listed. Application Type 1 represents maximum capability up to 100% braking torque where possible. Application Type 2 represents more than 100% braking torque where possible, up to a maximum of 150%.
    ‡ Always check resistor Ohms against minimum resistance for drive being used.

    PowerFlex 70 Medium Duty External Dynamic Brake Resistors

    These resistors provide a larger duty cycle capability than the internal type. Includes an internal thermal switch for use in external safety circuit.

    PowerFlex 70 AC Drive Medium Duty External DB Resistor
    Normal Duty⋆ 
    kW (Hp)
    Heavy Duty⋆ 
    kW (Hp)
    Min DB Res
    Ohms ±10%
    Cat. No. Resistance‡ 
    Ohms ±5%
    Continuous Power
    kW
    Max Energy
    kJ
    Max Braking Torque
    % of ND Motor
    Application Type 1 Application Type 2
    Braking Torque
    % of ND Motor
    Duty Cycle Braking Torque
    % of ND Motor
    Duty Cycle
    200…240 Volt AC Input Drives
    0.37 (0.5) 0.25 (0.33) 33 AK-R2-091P500 91 0.086 17 293% 100% 46% 150% 31%
    0.75 (1.0) 0.55 (0.75) 33 AK-R2-091P500 91 0.086 17 218% 100% 23% 150% 15%
    1.5 (2.0) 1.1 (1.5) 33 AK-R2-091P500 91 0.086 17 109% 100% 11% 109% 11%
    2.2 (3.0) 1.5 (2.0) 33 AK-R2-047P500 47 0.166 33 144% 100% 15% 144% 11%
    4.0 (5.0) 3.0 (3.0) 30 AK-R2-047P500 47 0.166 33 79% 79% 11% N/A N/A
    5.5 (7.5) 4.0 (5.0) 23 AK-R2-030P1K2 30 0.26 52 90% 90% 10% N/A N/A
    7.5 (10) 5.5 (7.5) 23 AK-R2-030P1K2 30 0.26 52 66% 66% 10% N/A N/A
    400…480 Volt AC Input Drives
    0.37 (0.5) 0.25 (0.33) 68 AK-R2-360P500 360 0.086 17 305% 100% 47% 150% 31%
    0.75 (1.0) 0.55 (0.75) 68 AK-R2-360P500 360 0.086 17 220% 100% 23% 150% 15%
    1.5 (2.0) 1.1 (1.5) 68 AK-R2-360P500 360 0.086 17 110% 100% 12% 110% 11%
    2.2 (3.0) 1.5 (2.0) 68 AK-R2-120P1K2 120 0.26 52 197% 100% 24% 150% 16%
    4.0 (5.0) 3.0 (3.0) 68 AK-R2-120P1K2 120 0.26 52 124% 100% 13% 124% 10%
    5.5 (7.5) 4.0 (5.0) 74 AK-R2-120P1K2 120 0.26 52 90% 90% 10% N/A N/A
    7.5 (10) 5.5 (7.5) 74 AK-R2-120P1K2 120 0.26 52 66% 66% 10% N/A N/A
    11 (15) §  7.5 (10) §  44 §  60 0.52 104 90% 90% 10% N/A N/A
    15 (20) §  11 (15) §  31 §  60 0.52 104 66% 66% 10% N/A N/A
    500…600 Volt AC Input Drives
    0.37 (0.5) 0.25 (0.33) 117 AK-R2-360P500 360 0.086 17 274% 100% 46% 150% 31%
    0.75 (1.0) 0.55 (0.75) 117 AK-R2-360P500 360 0.086 17 251% 100% 23% 150% 15%
    1.5 (2.0) 1.1 (1.5) 117 AK-R2-360P500 360 0.086 17 172% 100% 11% 150% 8%
    2.2 (3.0) 1.5 (2.0) 117 AK-R2-120P1K2 120 0.26 52 193% 100% 24% 150% 16%
    4.0 (5.0) 3.0 (3.0) 80 AK-R2-120P1K2 120 0.26 52 185% 100% 13% 150% 9%
    5.5 (7.5) 4.0 (5.0) 80 AK-R2-120P1K2 120 0.26 52 141% 100% 9% 141% 7%
    7.5 (10) 5.5 (7.5) 80 AK-R2-120P1K2 120 0.26 52 103% 100% 7% 103% 7%
    11 (15) §  7.5 (10) §  48 §  60 0.52 104 141% 100% 9% 141% 7%
    15 (20) §  11 (15) §  48 §  60 0.52 104 103% 100% 7% 103% 7%
    ⋆ Duty cycle listed is based on full speed to zero speed deceleration. For constant regen at full speed, duty cycle capability is half of what is listed. Application Type 1 represents maximum capability up to 100% braking torque where possible. Application Type 2 represents more than 100% braking torque where possible, up to a maximum of 150%.
    ‡ Always check resistor Ohms against minimum resistance for drive being used.
    § For 11 and 15 kW (15 and 20 Hp) applications, use two 7.5 kW (10 Hp) size resistors wired in parallel.

    Internal Dynamic Brake Resistor Kits

    These resistors have a limited duty cycle. Refer to the PowerFlex Dynamic Braking Selection Guide to determine if an internal resistor will be sufficient for your application. An external resistor may be required.

    Drive Input Voltage Brake Resistance Frame Cat. No. Used with PowerFlex Drive
    W 70 700 700H 700S 700L 753/755
    208…240V AC 62 0 20BB-DB1-0   ü   ü    
    62 1 (except 7.5 Hp) 20BB-DB1-1   ü   ü    
    22 1 (7.5 Hp) 20BB-DB2-1   ü   ü    
    22 2 20BB-DB1-2   ü   ü    
    380…600V AC 115 0 20BD-DB1-0   ü   ü    
    115 1 20BD-DB1-1   ü   ü    
    68 2 20BD-DB1-2   ü   ü    
    62 2 20-750-DB1-D2           ü
      

    Terminators
    Description ‡  Cat. No. Used with PowerFlex Drive
    70 700 700H 700S 700L 753/755
    for use with 3.7 kW (5 Hp) & below drives 1204-TFA1 ü ü   ü ü ü
    for use with 1.5 kW (2 Hp) & up drives 1204-TFB2 ü ü ü ü ü ü
    ‡ Refer to Appendix A of publication Drives-IN001 for selection information.

    Reflected Wave Reduction Modules w/Common Mode Choke
    Description ‡  Cat. No. Used with PowerFlex Drive
    70 700 700H 700S 700L 753/755
    17A with Common Mode Choke 1204-RWC-17-A ü ü ü ü   ü
    ‡ Refer to Appendix A of publication Drives-IN001 for selection information.

    Reflected Wave Reduction Modules
    Voltage ND kW ND Hp Cat. No. Used with PowerFlex Drive
    70 700 700H 700S 700L 753/755
    380…480V AC 4 5 1321-RWR8-DP ü ü   ü   ü
    5.5 7.5 1321-RWR12-DP ü ü   ü   ü
    7.5 10 1321-RWR18-DP ü ü   ü   ü
    11 15 1321-RWR25-DP ü ü   ü   ü
    15 20 1321-RWR35-DP ü ü   ü   ü
    18.5 25 1321-RWR35-DP ü ü   ü   ü
    22 30 1321-RWR45-DP ü ü   ü   ü
    30 40 1321-RWR55-DP ü ü   ü   ü
    37 50 1321-RWR80-DP ü ü   ü   ü
    45 60 1321-RWR80-DP   ü   ü   ü
    55 75 1321-RWR100-DP   ü   ü   ü
    75 100 1321-RWR130-DP   ü   ü   ü
    75 100 1321-RWR160-DP       ü    
    90 125 1321-RWR160-DP   ü   ü   ü
    110 150 1321-RWR200-DP   ü   ü   ü
    149 200 1321-RWR250-DP   ü ü ü   ü
    149 200 1321-RWR320-DP       ü    
    187 250 1321-RWR320-DP   ü ü ü   ü
    500…600V AC 4 5 1321-RWR8-EP ü ü   ü    
    5.5 7.5 1321-RWR8-EP       ü    
    5.5 7.5 1321-RWR12-EP ü ü        
    7.5 10 1321-RWR12-EP ü ü   ü    
    11 15 1321-RWR18-EP ü ü   ü    
    15 20 1321-RWR25-EP ü ü   ü    
    18.5 25 1321-RWR25-EP       ü    
    18.5 25 1321-RWR35-EP ü ü        
    22 30 1321-RWR35-EP ü ü   ü    
    30 40 1321-RWR45-EP ü ü   ü    
    37 50 1321-RWR55-EP ü ü   ü    
    45 60 1321-RWR80-EP   ü   ü    
    55 75 1321-RWR80-EP   ü   ü    
    75 100 1321-RWR100-EP   ü   ü    
    90 125 1321-RWR130-EP   ü   ü    
    110 150 1321-RWR160-EP   ü   ü    
    110 150 1321-RWR200-EP       ü    
    149 200 1321-RWR200-EP       ü    
      

    1492 Wiring System Modules and Cables

    Wiring System Modules and Cables provide an easy means to extend drive control wiring. A pre-wired cable (available in various lengths) plugs into the appropriate drive I/O terminal block. The remaining cable end plugs into the Wiring Module which provides a terminal block for direct I/O connection. See publication 1492-TD008 for detailed information.

    1492 Wiring Module and Cable Selection
    Drive I/O Wiring Module Description Wiring Module Cat. No. PowerFlex 700H Cable (see below) PowerFlex 700S Cable (see below) Used with PowerFlex Drive
    Fixed Terminal Block Removable Terminal Block 70 700 700H 700S 700L 753/755
    Analog I/O (TB1) 6 Channel Isolated - 3 Terminals/Ch. 1492-AIFM6S-3 1492-RAIFM6S-3 1492-ACABxxxZ7H 1492-ACABxxxZ7S     ü ü    
    DC Discrete Digital I/O (TB2) Standard,
    264V AC/DC
    1492-IFM20F 1492-RIFM20F 1492-CABxxxA7H 1492-CABxxxA7S     ü ü    
    Narrow Standard,
    132V AC/DC
    1492-IFM20FN 1492-RIFM20FN 1492-CABxxxA7H 1492-CABxxxA7S     ü ü    
    Extra Terminals
    (2 per I/O), 264V AC/DC
    1492-IFM20F-2 1492-RIFM20F-2 1492-CABxxxA7H 1492-CABxxxA7S     ü ü    
    AC Discrete Digital I/O (20C-DA1-B & 20C-DO1) Standard,
    264V AC/DC
    1492-IFM20F 1492-RIFM20F 1492-CABxxxB7H 1492-CABxxxB7H     ü      
    Narrow Standard,
    132V AC/DC
    1492-IFM20FN 1492-RIFM20FN 1492-CABxxxB7H 1492-CABxxxB7H     ü      
    Extra Terminals
    (2 per I/O), 264V AC/DC
    1492-IFM20F-2 1492-RIFM20F-2 1492-CABxxxB7H 1492-CABxxxB7H     ü      
    Encoder 2 Channel Encoder Input - 4 Outputs 1492-AIFMCE4 1492-ACABxxxX7S 1492-ACABxxxX7S       ü    
    2 Channel Fused Encoder Input - 4 Fused Outputs 1492-AIFMCE4-F 1492-ACABxxxX7S 1492-ACABxxxX7S       ü    
      

    1492 Pre-Wired Cable Assemblies
    Description PowerFlex 700H Cat. No. PowerFlex 700S Cat. No. Used with PowerFlex Drive
    70 700 700H 700S 700L 753/755
    Pre-Wired Cable for Analog I/O
    0.5 Meter (1.6 Feet) 1492-ACAB005Z7H 1492-ACAB005Z7S     ü ü    
    1.0 Meter (3.3 Feet) 1492-ACAB010Z7H 1492-ACAB010Z7S     ü ü    
    2.5 Meters (8.2 Feet) 1492-ACAB025Z7H 1492-ACAB025Z7S     ü ü    
    5.0 Meters (16.4 Feet) 1492-ACAB050Z7H 1492-ACAB050Z7S     ü ü    
    Pre-Wired Cable for Discrete DC I/O
    0.5 Meter (1.6 Feet) 1492-CAB005A7H 1492-CAB005A7S     ü ü    
    1.0 Meter (3.3 Feet) 1492-CAB010A7H 1492-CAB005A7S     ü ü    
    2.5 Meters (8.2 Feet) 1492-CAB025A7H 1492-CAB025A7S     ü ü    
    5.0 Meters (16.4 Feet) 1492-CAB050A7H 1492-CAB050A7S     ü ü    
    Pre-Wired Cable for Discrete AC I/O
    0.5 Meter (1.6 Feet) 1492-CAB005B7H     ü      
    1.0 Meter (3.3 Feet) 1492-CAB010B7H     ü      
    2.5 Meters (8.2 Feet) 1492-CAB025B7H     ü      
    5.0 Meters (16.4 Feet) 1492-CAB050B7H     ü      
    Pre-Wired Cable for Encoder
    0.5 Meter (1.6 Feet) 1492-ACAB005X7S       ü    
    1.0 Meter (3.3 Feet) 1492-ACAB010X7S       ü    
    2.5 Meters (8.2 Feet) 1492-ACAB025X7S       ü    
    5.0 Meters (16.4 Feet) 1492-ACAB050X7S       ü    
     

    Isolation Transformers - IP32, NEMA/UL Type 3R Standalone, 4…6% Nominal Impedance
           
      Click to enlarge - xfmr_sch1 Click to enlarge - xfmr_sch2  
      Diagram 1 Diagram 2  

    Motor Rating Wiring Diagram 240V, 60 Hz, Three-Phase, 240V Primary & 240V Secondary ⋆  460V, 60 Hz, Three-Phase, 460V Primary & 460V Secondary 575V, 60 Hz, Three-Phase 575V Primary & 575V Secondary ⋆  Used with PowerFlex Drive
    kW Hp Cat. No. Cat. No. Cat. No. 70 700 700H 700S 700L 753/755
    0.25 0.33 1 1321-3TW005-AA 1321-3TW005-BB ü ü   ü    
    0.37 0.5 1 1321-3TW005-AA 1321-3TW005-BB 1321-3TW005-CC ü ü   ü    
    0.55 0.75 1 1321-3TW005-AA 1321-3TW005-BB ü ü   ü    
    0.75 1 1 1321-3TW005-AA 1321-3TW005-BB 1321-3TW005-CC ü ü   ü   ü
    1.1 1.5 1 1321-3TW005-AA 1321-3TW005-BB ü ü   ü    
    1.5 2 1 1321-3TW005-AA 1321-3TW005-BB 1321-3TW005-CC ü ü   ü   ü
    2.2 3 1 1321-3TW005-AA 1321-3TW005-BB 1321-3TW005-CC ü ü   ü   ü
    22 30 2 1321-3TW040-AA 1321-3TW040-BB 1321-3TW040-CC ü ü   ü   ü
    30 40 2 1321-3TW051-AA 1321-3TW051-BB 1321-3TW051-CC ü ü   ü   ü
    37 50 2 1321-3TH063-AA 1321-3TH063-BB 1321-3TH063-CC ü ü   ü   ü
    45 60 2 1321-3TH075-AA 1321-3TH075-BB 1321-3TH075-CC   ü   ü   ü
    55 75 2 1321-3TH093-AA 1321-3TH093-BB 1321-3TH093-CC   ü   ü   ü
    75 100 2 1321-3TH118-BB 1321-3TH118-CC   ü   ü   ü
    90 125 2 1321-3TH145-BB 1321-3TH145-CC   ü   ü   ü
    110 150 2 1321-3TH175-BB 1321-3TH175-CC   ü ü ü   ü
    149 200 2 1321-3TH220-BB 1321-3TH220-CC   ü ü ü   ü
    187 250 2 1321-3TH275-BB 1321-3TH275-CC   ü ü     ü
    224 300 2 1321-3TH330-BB 1321-3TH330-CC   ü ü     ü
    224 300 1 1321-3TH330-CC           ü
    261 350 1 1321-3TH440-BB 1321-3TH440-CC   ü ü     ü
    298 400 1 1321-3TH440-BB 1321-3TH440-CC   ü ü      
    298 400 1 1321-3TH440-BB 1321-3TH550-CC           ü
    336 450 1 1321-3TH550-BB 1321-3TH550-CC   ü ü     ü
    373 500 1 1321-3TH550-BB 1321-3TH550-CC   ü ü      
    373 500 1 1321-3TH550-BB 1321-3TH660-CC           ü
    410 550 1 1321-3TH660-CC           ü
    448 600 1 1321-3TH660-BB 1321-3TH660-CC   ü ü      
    448 600 1 1321-3TH660-BB 1321-3TH770-CC           ü
    485 650 1 1321-3TH770-CC   ü ü      
    522 700 1 1321-3TH770-BB 1321-3TH770-CC   ü ü     ü
    597 800 1 1321-3TH880-BB 1321-3TH880-CC           ü
    671 900 900 kVA ‡  950 kVA ‡            ü
    709 950 1000 kVA ‡            ü
    746 1000 1000 kVA ‡  1100 kVA ‡            ü
    821 1100 1200 kVA ‡            ü
    895 1200 1200 kVA ‡            ü
    933 1250 1200 kVA ‡            ü
    1007 1350 1300 kVA ‡            ü
    1119 1500 1500 kVA ‡  1500 kVA ‡            ü
    1492 2000 2000 kVA ‡            ü
      
    ⋆ Not applicable for the PowerFlex 755.
    ‡  1321 Isolation Transformer solution is not available. Approximate drive kVA is listed.

    Input and Output Reactors - 200…240V, 50/60 Hz, Three-Phase, 3% Impedance
    kW Hp Duty Input Line Reactor ‡  Output Reactor ‡  Used with PowerFlex Drive
    IP00
    (Open Style)
    IP11
    (NEMA/UL Type 1)
    IP00
    (Open Style)
    IP11
    (NEMA/UL Type 1)
    70 700 700H 700S 700L 753/755
    0.25 0.33 Heavy 1321-3R2-D 1321-3RA2-D 1321-3R2-D 1321-3RA2-D ü ü   ü    
    0.37 0.5 Normal 1321-3R2-D 1321-3RA2-D 1321-3R2-D 1321-3RA2-D ü ü   ü    
    0.55 0.75 Heavy 1321-3R4-A 1321-3RA4-A 1321-3R4-A 1321-3RA4-A ü ü   ü    
    0.75 1 Normal 1321-3R4-A 1321-3RA4-A 1321-3R4-A 1321-3RA4-A ü ü   ü    
    1.1 1.5 Heavy 1321-3R8-B 1321-3RA8-B 1321-3R8-A 1321-3RA8-A ü ü   ü    
    1.5 2 Normal 1321-3R8-A 1321-3RA8-A 1321-3R8-A 1321-3RA8-A ü ü   ü    
    Heavy 1321-3R8-A 1321-3RA8-A 1321-3R12-A 1321-3RA12-A ü ü   ü    
    2.2 3 Normal 1321-3R12-A 1321-3RA12-A 1321-3R12-A 1321-3RA12-A ü ü   ü    
    Heavy 1321-3R12-A 1321-3RA12-A 1321-3R18-A 1321-3RA18-A ü ü   ü    
    4 5 Normal 1321-3R18-A 1321-3RA18-A 1321-3R18-A 1321-3RA18-A ü ü   ü    
    Heavy 1321-3R18-A 1321-3RA18-A 1321-3R25-A 1321-3RA25-A ü ü   ü    
    5.5 7.5 Normal 1321-3R25-A 1321-3RA25-A 1321-3R25-A 1321-3RA25-A ü ü   ü    
    Heavy 1321-3R25-A 1321-3RA25-A 1321-3R35-A 1321-3RA35-A ü ü   ü    
    7.5 10 Normal 1321-3R35-A 1321-3RA35-A 1321-3R35-A 1321-3RA35-A ü ü   ü    
    Heavy 1321-3R35-A 1321-3RA35-A 1321-3R45-A 1321-3RA45-A ü ü   ü    
    11 15 Normal 1321-3R45-A 1321-3RA45-A 1321-3R45-A 1321-3RA45-A ü ü   ü    
    Heavy 1321-3R45-A 1321-3RA45-A 1321-3R55-A 1321-3RA55-A ü ü   ü    
    15 20 Normal 1321-3R55-A 1321-3RA55-A 1321-3R55-A 1321-3RA55-A ü ü   ü    
    Heavy 1321-3R55-A 1321-3RA55-A 1321-3R80-A 1321-3RA80-A ü ü   ü    
    18.5 25 Normal 1321-3R80-A 1321-3RA80-A 1321-3R80-A 1321-3RA80-A ü ü   ü    
    Heavy 1321-3R80-A 1321-3RA80-A 1321-3R80-A 1321-3RA80-A   ü   ü    
    22 30 Normal 1321-3R80-A 1321-3RA80-A 1321-3R80-A 1321-3RA80-A   ü   ü    
    Heavy 1321-3R80-A 1321-3RA80-A 1321-3R80-A 1321-3RA80-A   ü   ü    
    30 40 Normal 1321-3R100-A 1321-3RA100-A 1321-3R100-A 1321-3RA100-A   ü   ü    
    Heavy 1321-3R100-A 1321-3RA100-A 1321-3R100-A 1321-3RA100-A   ü   ü    
    37 50 Normal 1321-3R130-A 1321-3RA130-A 1321-3R130-A 1321-3RA130-A   ü   ü    
    Heavy 1321-3R130-A 1321-3RA130-A 1321-3R130-A 1321-3RA130-A   ü   ü    
    45 60 Normal 1321-3R160-A 1321-3RA160-A 1321-3R160-A 1321-3RA160-A   ü   ü    
    Heavy 1321-3R160-A 1321-3RA160-A 1321-3R160-A 1321-3RA160-A   ü   ü    
    55 75 Normal 1321-3R200-A 1321-3RA200-A 1321-3R200-A 1321-3RA200-A   ü   ü    
    Heavy 1321-3R200-A 1321-3RA200-A 1321-3R200-A 1321-3RA200-A   ü   ü    
    75 100 Normal 1321-3RB250-A 1321-3RAB250-A 1321-3RB250-A 1321-3RAB250-A   ü   ü    
    ‡ Input line reactors were sized based on the NEC fundamental motor amps. Output line reactors were sized based on the VFD rated output currents.

    Input and Output Reactors - 200…240V, 50/60 Hz, Three-Phase, 5% Impedance
    kW Hp Duty Input Line Reactor ‡  Output Reactor ‡  Used with PowerFlex Drive
    IP00
    (Open Style)
    IP11
    (NEMA/UL Type 1)
    IP00
    (Open Style)
    IP11
    (NEMA/UL Type 1)
    70 700 700H 700S 700L 753/755
    0.25 0.33 Heavy 1321-3R2-A 1321-3RA2-A 1321-3R2-A 1321-3RA2-A ü ü   ü    
    0.37 0.5 Normal 1321-3R2-A 1321-3RA2-A 1321-3R2-A 1321-3RA2-A ü ü   ü    
    0.55 0.75 Heavy 1321-3R4-B 1321-3RA4-B 1321-3R4-B 1321-3RA4-B ü ü   ü    
    0.75 1 Normal 1321-3R4-B 1321-3RA4-B 1321-3R4-B 1321-3RA4-B ü ü   ü    
    1.1 1.5 Heavy 1321-3R8-B 1321-3RA8-B 1321-3R8-B 1321-3RA8-B ü ü   ü    
    1.5 2 Normal 1321-3R8-B 1321-3RA8-B 1321-3R8-B 1321-3RA8-B ü ü   ü    
    Heavy 1321-3R8-B 1321-3RA8-B 1321-3R12-B 1321-3RA12-B ü ü   ü    
    2.2 3 Normal 1321-3R12-B 1321-3RA12-B 1321-3R12-B 1321-3RA12-B ü ü   ü    
    Heavy 1321-3R12-B 1321-3RA12-B 1321-3R18-B 1321-3RA18-B ü ü   ü    
    4 5 Normal 1321-3R18-B 1321-3RA18-B 1321-3R18-B 1321-3RA18-B ü ü   ü    
    Heavy 1321-3R18-B 1321-3RA18-B 1321-3R25-B 1321-3RA25-B ü ü   ü    
    5.5 7.5 Normal 1321-3R25-B 1321-3RA25-B 1321-3R25-B 1321-3RA25-B ü ü   ü    
    Heavy 1321-3R25-B 1321-3RA25-B 1321-3R35-B 1321-3RA35-B ü ü   ü    
    7.5 10 Normal 1321-3R35-B 1321-3RA35-B 1321-3R35-B 1321-3RA35-B ü ü   ü    
    Heavy 1321-3R35-B 1321-3RA35-B 1321-3R45-B 1321-3RA45-B ü ü   ü    
    11 15 Normal 1321-3R45-B 1321-3RA45-B 1321-3R45-B 1321-3RA45-B ü ü   ü    
    Heavy 1321-3R45-B 1321-3RA45-B 1321-3R55-B 1321-3RA55-B ü ü   ü    
    15 20 Normal 1321-3R55-B 1321-3RA55-B 1321-3R55-B 1321-3RA55-B ü ü   ü    
    Heavy 1321-3R55-B 1321-3RA55-B 1321-3R80-B 1321-3RA80-B ü ü   ü    
    18.5 25 Normal 1321-3R80-B 1321-3RA80-B 1321-3R80-B 1321-3RA80-B   ü   ü    
    Heavy 1321-3R80-B 1321-3RA80-B 1321-3R80-B 1321-3RA80-B   ü   ü    
    22 30 Normal 1321-3R80-B 1321-3RA80-B 1321-3R80-B 1321-3RA80-B   ü   ü    
    Heavy 1321-3R80-B 1321-3RA80-B 1321-3R80-B 1321-3RA80-B   ü   ü    
    30 40 Normal 1321-3R100-B 1321-3RA100-B 1321-3R100-B 1321-3RA100-B   ü   ü    
    Heavy 1321-3R100-B 1321-3RA100-B 1321-3R100-B 1321-3RA100-B   ü   ü    
    37 50 Normal 1321-3R130-B 1321-3RA130-B 1321-3R130-B 1321-3RA130-B   ü   ü    
    Heavy 1321-3R130-B 1321-3RA130-B 1321-3R130-B 1321-3RA130-B   ü   ü    
    45 60 Normal 1321-3R160-B 1321-3RA160-B 1321-3R160-B 1321-3RA160-B   ü   ü    
    Heavy 1321-3R160-B 1321-3RA160-B 1321-3R160-B 1321-3RA160-B   ü   ü    
    55 75 Normal 1321-3R200-B 1321-3RA200-B 1321-3R200-B 1321-3RA200-B   ü   ü    
    Heavy 1321-3R200-B 1321-3RA200-B 1321-3R200-B 1321-3RA200-B   ü   ü    
    75 100 Normal 1321-3RB250-B 1321-3RAB250-B 1321-3RB250-B 1321-3RAB250-B   ü   ü    
    ‡ Input line reactors were sized based on the NEC fundamental motor amps. Output line reactors were sized based on the VFD rated output currents.

    Input and Output Reactors - 380…480V, 50/60 Hz, Three-Phase, 3% Impedance
    kW Hp Duty Input Line Reactor ‡  Output Reactor ‡  Used with PowerFlex Drive
    IP00
    (Open Style)
    IP11
    (NEMA/UL Type 1)
    IP00
    (Open Style)
    IP11
    (NEMA/UL Type 1)
    70 700 700H 700S 700L 753/755
    0.25 0.33 Heavy 1321-3R1-C 1321-3RA1-C 1321-3R2-B 1321-3RA2-B ü ü   ü    
    0.37 0.5 Normal 1321-3R1-C 1321-3RA1-C 1321-3R2-B 1321-3RA2-B ü ü   ü    
    0.55 0.75 Heavy 1321-3R2-A 1321-3RA2-A 1321-3R2-A 1321-3RA2-A ü ü   ü    
    0.75 1 Normal 1321-3R2-A 1321-3RA2-A 1321-3R2-A 1321-3RA2-A ü ü   ü   ü
    1.1 1.5 Heavy 1321-3R4-C 1321-3RA4-C 1321-3R4-B 1321-3RA4-B ü ü   ü   ü
    1.5 2 Normal 1321-3R4-B 1321-3RA4-B 1321-3R4-B 1321-3RA4-B ü ü   ü   ü
    Heavy 1321-3R4-B 1321-3RA4-B 1321-3R8-C 1321-3RA8-C ü ü   ü   ü
    2.2 3 Normal 1321-3R8-C 1321-3RA8-C 1321-3R8-C 1321-3RA8-C ü ü   ü   ü
    Heavy 1321-3R8-C 1321-3RA8-C 1321-3R8-B 1321-3RA8-B ü ü   ü   ü
    4 5 Normal 1321-3R8-B 1321-3RA8-B 1321-3R8-B 1321-3RA8-B ü ü   ü   ü
    Heavy 1321-3R8-B 1321-3RA8-B 1321-3R12-B 1321-3RA12-B ü ü   ü   ü
    5.5 7.5 Normal 1321-3R12-B 1321-3RA12-B 1321-3R12-B 1321-3RA12-B ü ü   ü   ü
    Heavy 1321-3R12-B 1321-3RA12-B 1321-3R18-B 1321-3RA18-B ü ü   ü   ü
    7.5 10 Normal 1321-3R18-B 1321-3RA18-B 1321-3R18-B 1321-3RA18-B ü ü   ü   ü
    Heavy 1321-3R18-B 1321-3RA18-B 1321-3R25-B 1321-3RA25-B ü ü   ü   ü
    11 15 Normal 1321-3R25-B 1321-3RA25-B 1321-3R25-B 1321-3RA25-B ü ü   ü   ü
    Heavy 1321-3R25-B 1321-3RA25-B 1321-3R25-B 1321-3RA25-B ü ü   ü   ü
    15 20 Normal 1321-3R35-B 1321-3RA35-B 1321-3R25-B 1321-3RA25-B ü ü   ü   ü
    Heavy 1321-3R35-B 1321-3RA35-B 1321-3R35-B 1321-3RA35-B ü ü   ü   ü
    18.5 25 Normal 1321-3R35-B 1321-3RA35-B 1321-3R35-B 1321-3RA35-B ü ü   ü   ü
    Heavy 1321-3R35-B 1321-3RA35-B 1321-3R45-B 1321-3RA45-B ü ü   ü   ü
    22 30 Normal 1321-3R45-B 1321-3RA45-B 1321-3R45-B 1321-3RA45-B ü ü   ü   ü
    Heavy 1321-3R45-B 1321-3RA45-B 1321-3R55-B 1321-3RA55-B ü ü   ü   ü
    30 40 Normal 1321-3R55-B 1321-3RA55-B 1321-3R55-B 1321-3RA55-B ü ü   ü   ü
    Heavy 1321-3R55-B 1321-3RA55-B 1321-3R80-B 1321-3RA80-B ü ü   ü   ü
    37 50 Normal 1321-3R80-B 1321-3RA80-B 1321-3R80-B 1321-3RA80-B ü ü   ü   ü
    Heavy 1321-3R80-B 1321-3RA80-B 1321-3R80-B 1321-3RA80-B   ü   ü   ü
    45 60 Normal/Heavy 1321-3R80-B 1321-3RA80-B 1321-3R80-B 1321-3RA80-B   ü   ü   ü
    55 75 Normal/Heavy 1321-3R100-B 1321-3RA100-B 1321-3R100-B 1321-3RA100-B   ü   ü   ü
    75 100 Normal/Heavy 1321-3R130-B 1321-3RA130-B 1321-3R130-B 1321-3RA130-B   ü   ü   ü
    90 125 Normal/Heavy 1321-3R160-B 1321-3RA160-B 1321-3R160-B 1321-3RA160-B   ü   ü   ü
    110 150 Normal 1321-3R200-B 1321-3RA200-B 1321-3R200-C 1321-3RA200-C   ü ü ü   ü
    Heavy 1321-3R200-B 1321-3RA200-B 1321-3R200-C 1321-3RA200-C   ü   ü   ü
    Heavy 1321-3R200-B 1321-3RA200-B     ü      
    200 Normal/Heavy 1321-3RB250-B 1321-3RAB250-B 1321-3RB250-B 1321-3RAB250-B           ü
    132 Normal/Heavy 1321-3RB250-B 1321-3RAB250-B 1321-3RB250-B 1321-3RAB250-B           ü
    149 200 Normal 1321-3RB250-B 1321-3RAB250-B 1321-3RB250-B 1321-3RAB250-B   ü ü ü    
    Heavy 1321-3RB250-B 1321-3RAB250-B 1321-3RB250-B 1321-3RAB250-B   ü ü ü    
    160 250 Normal/Heavy 1321-3RB320-B 1321-3RAB320-B 1321-3RB320-B 1321-3RAB320-B           ü
    187 250 Normal/Heavy 1321-3RB320-B 1321-3RAB320-B 1321-3RB320-B 1321-3RAB320-B   ü ü      
    200 300 Normal 1321-3RB400-B 1321-3RAB400-B 1321-3RB400-B 1321-3RAB400-B   ü ü     ü
    Heavy 1321-3RB400-B 1321-3RAB400-B 1321-3RB400-B 1321-3RAB400-B   ü ü     ü
    350 Normal/Heavy 1321-3R500-B 1321-3R500-B 1321-3R500-B 1321-3R500-B           ü
    250 Normal/Heavy 1321-3R500-B 1321-3RA500-B 1321-3R500-B 1321-3RA500-B           ü
    261 350 Normal 1321-3RB400-B 1321-3RAB400-B 1321-3RB400-B 1321-3RAB400-B   ü        
    Heavy 1321-3RB400-B 1321-3RAB400-B 1321-3RB400-B 1321-3RAB400-B   ü ü      
    Normal 1321-3R500-B 1321-3RA500-B     ü      
    continued
    ‡ Input line reactors were sized based on the NEC fundamental motor amps (PowerFlex 700H has an integral input reactor). Output line reactors were sized based on the VFD rated output currents.
    § Requires two output reactors wired in parallel.

    Input and Output Reactors - 380…480V, 50/60 Hz, Three-Phase, 3% Impedance (continued)
    kW Hp Duty ♦  Input Line Reactor ‡  Output Reactor ‡  Used with PowerFlex Drive
    IP00
    (Open Style)
    IP11
    (NEMA/UL Type 1)
    IP00
    (Open Style)
    IP11
    (NEMA/UL Type 1)
    70 700 700H 700S 700L 753/755
    400 Light/Normal/Heavy 1321-3R500-B 1321-3RA500-B 1321-3R500-B 1321-3RA500-B           ü
    280 400 Normal/Heavy 1321-3R500-B 1321-3RA500-B 1321-3R500-B 1321-3RA500-B   ü        
    315 Light/Normal/Heavy 1321-3R600-B 1321-3RA600-B 1321-3R600-B 1321-3RA600-B           ü
    450 Light/Normal/Heavy 1321-3R600-B 1321-3RA600-B 1321-3R600-B 1321-3RA600-B           ü
    336 450 Normal/Heavy 1321-3R500-B 1321-3RA500-B 1321-3R500-B 1321-3RA500-B   ü ü      
    355 Light/Normal/Heavy 1321-3R750-B 1321-3RA750-B 1321-3R750-B 1321-3RA750-B           ü
    500 Light 1321-3R600-B 1321-3RA600-B 1321-3R600-B 1321-3RA600-B           ü
    Normal/Heavy 1321-3R750-B 1321-3RA750-B 1321-3R750-B 1321-3RA750-B           ü
    373 500 Normal/Heavy 1321-3R600-B 1321-3RA600-B 1321-3R600-B 1321-3RA600-B   ü ü      
    400 Light/Heavy 1321-3R750-B 1321-3RA750-B 1321-3R750-B 1321-3RA750-B           ü
    Normal 1321-3R850-B 1321-3RA850-B 1321-3R850-B 1321-3RA850-B           ü
    600 Light/Normal/Heavy 1321-3R750-B 1321-3RA750-B 1321-3R750-B 1321-3RA750-B           ü
    448 600 Normal 1321-3R750-B 1321-3RA750-B 1321-3R750-B 1321-3RA750-B   ü ü      
    Heavy 1321-3R750-B 1321-3RA750-B     ü      
    Heavy 1321-3R750-B 1321-3RA750-B 1321-3R600-B 1321-3RA600-B   ü        
    450 Light 1321-3R850-B 1321-3RA850-B 1321-3R850-B 1321-3RA850-B           ü
    650 Light 1321-3R850-B 1321-3RA850-B 1321-3R850-B 1321-3RA850-B           ü
    Normal 1321-3R750-B 1321-3RA750-B 1321-3R750-B 1321-3RA750-B           ü
    700 Light/Normal/Heavy 1321-3R850-B 1321-3RA850-B 1321-3R850-B 1321-3RA850-B           ü
    522 700 Normal 1321-3R850-B 1321-3RA850-B 1321-3R850-B 1321-3RA850-B   ü        
    Normal/Heavy 1321-3RB400-B 1321-3RB400-B     ü §       
    750 Heavy 1321-3R850-B 1321-3RA850-B 1321-3R850-B 1321-3RA850-B           ü
    500 Normal/Heavy 1321-3R1000-B 1321-3RA1000-B 1321-3R1000-B 1321-3RA1000-B           ü
    500 800 Normal/Heavy 1321-3R500-B 1321-3RA500-B     ü §       
    800 Light/Normal/Heavy 1321-3R1000-B 1321-3RA1000-B 1321-3R1000-B 1321-3RA1000-B           ü
    560 Light/Normal/Heavy 1321-3R600-B 1321-3RA600-B 1321-3R600-B 1321-3RA600-B           ü § 
    630 900 Light/Normal/Heavy 1321-3R600-B 1321-3RA600-B 1321-3R600-B 1321-3RA600-B           ü § 
    Normal 1321-3R500-B 1321-3RA500-B     ü §       
    Heavy 1321-3R600-B 1321-3RA600-B     ü §       
    710 1000 Light/Normal/Heavy 1321-3R600-B 1321-3RA600-B 1321-3R600-B 1321-3RA600-B           ü § 
    746 1000 Normal 1321-3R600-B 1321-3RA600-B     ü §       
    Heavy 1321-3R750-B 1321-3RA750-B     ü §       
    800 1100 Light/Normal 1321-3R750-B 1321-3RA750-B 1321-3R750-B 1321-3RA750-B           ü § 
    850 Light/Normal 1321-3R750-B 1321-3RA750-B 1321-3R750-B 1321-3RA750-B           ü § 
    895 1200 Normal 1321-3R750-B 1321-3RA750-B     ü §       
    900 Light 1321-3R850-B 1321-3RA850-B 1321-3R850-B 1321-3RA850-B           ü § 
    1250 Light/Normal 1321-3R750-B 1321-3RA750-B 1321-3R750-B 1321-3RA750-B           ü § 
    933 1250 Normal 1321-3R750-B 1321-3RA750-B     ü §       
    1350 Light 1321-3R850-B 1321-3RA850-B 1321-3R850-B 1321-3RA850-B           ü § 
    1500 Light 1321-3R850-B 1321-3RA850-B 1321-3R850-B 1321-3RA850-B           ü ♠ 
    1000 Light 1321-3R850-B 1321-3RA850-B 1321-3R850-B 1321-3RA850-B           ü ♠ 
    2000 Light 1321-3R850-B 1321-3RA850-B 1321-3R850-B 1321-3RA850-B           ü ♠ 
    1400 Light 1321-3R850-B 1321-3RA850-B 1321-3R850-B 1321-3RA850-B           ü ♠ 
    ‡ Input line reactors were sized based on the NEC fundamental motor amps (PowerFlex 700H has an integral input reactor). Output line reactors were sized based on the VFD rated output currents.
    § Requires two reactors wired in parallel.
    ♠ Requires three reactors wired in parallel.
    ♦ Light Duty refers to PowerFlex 755 drives only.

    Input and Output Reactors - 380…480V, 50/60 Hz, Three-Phase, 5% Impedance
    kW Hp Duty Input Line Reactor ‡  Output Reactor ‡  Used with PowerFlex Drive
    IP00
    (Open Style)
    IP11
    (NEMA/UL Type 1)
    IP00
    (Open Style)
    IP11
    (NEMA/UL Type 1)
    70 700 700H 700S 700L 753/755
    0.25 0.33 Heavy 1321-3R1-B 1321-3RA1-B 1321-3R2-C 1321-3RA2-C ü ü   ü    
    0.37 0.5 Normal 1321-3R1-B 1321-3RA1-B 1321-3R2-C 1321-3RA2-C ü ü   ü    
    0.55 0.75 Heavy 1321-3R2-C 1321-3RA2-C 1321-3R2-B 1321-3RA2-B ü ü   ü    
    0.75 1 Normal 1321-3R2-B 1321-3RA2-B 1321-3R2-B 1321-3RA2-B ü ü   ü   ü
    1.1 1.5 Heavy 1321-3R4-D 1321-3RA4-D 1321-3R4-D 1321-3RA4-D ü ü   ü   ü
    1.5 2 Normal 1321-3R4-D 1321-3RA4-D 1321-3R4-D 1321-3RA4-D ü ü   ü   ü
    Heavy 1321-3R4-D 1321-3RA4-D 1321-3R8-D 1321-3RA8-D ü ü   ü   ü
    2.2 3 Normal 1321-3R8-D 1321-3RA8-D 1321-3R8-D 1321-3RA8-D ü ü   ü   ü
    Heavy 1321-3R8-D 1321-3RA8-D 1321-3R8-C 1321-3RA8-C ü ü   ü   ü
    4 5 Normal 1321-3R8-C 1321-3RA8-C 1321-3R8-C 1321-3RA8-C ü ü   ü   ü
    Heavy 1321-3R8-C 1321-3RA8-C 1321-3R12-C 1321-3RA12-C ü ü   ü   ü
    5.5 7.5 Normal 1321-3R12-C 1321-3RA12-C 1321-3R12-C 1321-3RA12-C ü ü   ü   ü
    Heavy 1321-3R12-C 1321-3RA12-C 1321-3R18-C 1321-3RA18-C ü ü   ü   ü
    7.5 10 Normal 1321-3R18-C 1321-3RA18-C 1321-3R18-C 1321-3RA18-C ü ü   ü   ü
    Heavy 1321-3R18-C 1321-3RA18-C 1321-3R25-C 1321-3RA25-C ü ü   ü   ü
    11 15 Normal/Heavy 1321-3R25-C 1321-3RA25-C 1321-3R25-C 1321-3RA25-C ü ü   ü   ü
    15 20 Normal 1321-3R35-C 1321-3RA35-C 1321-3R25-C 1321-3RA25-C ü ü   ü   ü
    Heavy 1321-3R35-C 1321-3RA35-C 1321-3R35-C 1321-3RA35-C ü ü   ü   ü
    18.5 25 Normal 1321-3R35-C 1321-3RA35-C 1321-3R35-C 1321-3RA35-C ü ü   ü   ü
    Heavy 1321-3R35-C 1321-3RA35-C 1321-3R45-C 1321-3RA45-C ü ü   ü   ü
    22 30 Normal 1321-3R45-C 1321-3RA45-C 1321-3R45-C 1321-3RA45-C ü ü   ü   ü
    Heavy 1321-3R45-C 1321-3RA45-C 1321-3R55-C 1321-3RA55-C ü ü   ü   ü
    30 40 Normal 1321-3R55-C 1321-3RA55-C 1321-3R55-C 1321-3RA55-C ü ü   ü   ü
    Heavy 1321-3R55-C 1321-3RA55-C 1321-3R80-C 1321-3RA80-C ü ü   ü   ü
    37 50 Normal 1321-3R80-C 1321-3RA80-C 1321-3R80-C 1321-3RA80-C ü ü   ü   ü
    Heavy 1321-3R80-C 1321-3RA80-C 1321-3R80-C 1321-3RA80-C   ü   ü   ü
    45 60 Normal/Heavy 1321-3R80-C 1321-3RA80-C 1321-3R80-C 1321-3RA80-C   ü   ü   ü
    55 75 Normal/Heavy 1321-3R100-C 1321-3RA100-C 1321-3R100-C 1321-3RA100-C   ü   ü   ü
    75 100 Normal/Heavy 1321-3R130-C 1321-3RA130-C 1321-3R130-C 1321-3RA130-C   ü   ü   ü
    90 125 Normal/Heavy 1321-3R160-C 1321-3RA160-C 1321-3R160-C 1321-3RA160-C   ü   ü   ü
    110 150 Normal 1321-3R200-C 1321-3RA200-C 1321-3R200-C 1321-3RA200-C   ü   ü   ü
    Heavy 1321-3R200-C 1321-3RA200-C 1321-3R200-C 1321-3RA200-C   ü ü ü   ü
    Heavy 1321-3RB250-C 1321-3RAB250-C 1321-3RB250-C 1321-3RAB250-C     ü ü ♣     
    200 Normal/Heavy 1321-3RB250-C 1321-3RAB250-C 1321-3RB250-C 1321-3RAB250-C           ü
    132 Normal/Heavy 1321-3RB320-C 1321-3RAB320-C 1321-3RB320-C 1321-3RAB320-C           ü
    149 200 Normal 1321-3RB250-C 1321-3RAB250-C 1321-3RB250-C 1321-3RAB250-C   ü   ü ∆     
    Heavy 1321-3RB250-C 1321-3RAB250-C 1321-3RB250-C 1321-3RAB250-C   ü ü ü    
    160 250 Normal/Heavy 1321-3RB320-C 1321-3RAB320-C 1321-3RB320-C 1321-3RAB320-C           ü
    187 250 Normal/Heavy 1321-3RB320-C 1321-3RAB320-C 1321-3RB320-C 1321-3RAB320-C   ü ü      
    300 Normal/Heavy 1321-3RB400-C 1321-3RAB400-C 1321-3RB400-C 1321-3RAB400-C           ü
    200 Normal/Heavy 1321-3RB400-C 1321-3RAB400-C 1321-3RB400-C 1321-3RAB400-C           ü
    224 300 Normal/Heavy 1321-3RB400-C 1321-3RAB400-C 1321-3RB400-C 1321-3RAB400-C   ü ü      
    350 Normal/Heavy 1321-3R500-C 1321-3R500-C 1321-3R500-C 1321-3R500-C           ü
    250 Normal/Heavy 1321-3R500-C 1321-3RA500-C 1321-3R500-C 1321-3RA500-C           ü
    261 350 Normal 1321-3R500-C 1321-3RA500-C 1321-3RB400-C 1321-3RAB400-C   ü        
    Normal 1321-3R500-C 1321-3RA500-C 1321-3R500-C 1321-3RA500-C     ü      
    Heavy 1321-3R500-C 1321-3RA500-C 1321-3RB400-C 1321-3RAB400-C   ü ü      
    continued
    ‡ Input line reactors were sized based on the NEC fundamental motor amps (PowerFlex 700H has an integral input reactor). Output line reactors were sized based on the VFD rated output currents.
    ♣ For use with 300A PowerFlex 700S.
    ∆ For use with 248A and 261A PowerFlex 700S.

    Input and Output Reactors - 380…480V, 50/60 Hz, Three-Phase, 5% Impedance (continued)
    kW Hp Duty ♦  Input Line Reactor ‡  Output Reactor ‡  Used with PowerFlex Drive
    IP00
    (Open Style)
    IP11
    (NEMA/UL Type 1)
    IP00
    (Open Style)
    IP11
    (NEMA/UL Type 1)
    70 700 700H 700S 700L 753/755
    400 Light/Normal/Heavy 1321-3R500-C 1321-3RA500-C 1321-3R500-C 1321-3RA500-C           ü
    298 400 Normal/Heavy 1321-3R500-C 1321-3RA500-C 1321-3R500-C 1321-3RA500-C   ü        
    315 Light/Normal/Heavy 1321-3R600-C 1321-3RA600-C 1321-3R600-C 1321-3RA600-C           ü
    336 450 Normal/Heavy 1321-3RA600-C 1321-3RA600-C 1321-3R500-C 1321-3RA500-C   ü ü      
    450 Light/Normal/Heavy 1321-3R600-C 1321-3RA600-C 1321-3R600-C 1321-3RA600-C           ü
    355 Light/Normal/Heavy 1321-3R750-C 1321-3RA750-C 1321-3R750-C 1321-3RA750-C           ü
    373 500 Normal/Heavy 1321-3R600-C 1321-3RA600-C 1321-3R600-C 1321-3RA600-C   ü ü      
    500 Light 1321-3R600-C 1321-3RA600-C 1321-3R600-C 1321-3RA600-C           ü
    Normal/Heavy 1321-3R750-C 1321-3RA750-C 1321-3R750-C 1321-3RA750-C           ü
    400 Light/Heavy 1321-3R750-C 1321-3RA750-C 1321-3R750-C 1321-3RA750-C           ü
    Normal 1321-3R850-C 1321-3RA850-C 1321-3R850-C 1321-3RA850-C           ü
    448 600 Normal/Heavy 1321-3R750-E 1321-3RA750-E 1321-3R750-E 1321-3RA750-E   ü        
    600 Light/Normal/Heavy 1321-3R750-C 1321-3RA750-C 1321-3R750-C 1321-3RA750-C           ü
    450 Light 1321-3R850-C 1321-3RA850-C 1321-3R850-C 1321-3RA850-C           ü
    500 Normal/Heavy 1321-3R1000-C 1321-3RA1000-C 1321-3R1000-C 1321-3RA1000-C           ü
    522 600 Normal/Heavy 1321-3R750-C 1321-3RA750-C 1321-3R750-C 1321-3RA750-C     ü ⋆       
    650 Light 1321-3R850-C 1321-3RA850-C 1321-3R850-C 1321-3RA850-C           ü
    Normal 1321-3R750-C 1321-3RA750-C 1321-3R750-C 1321-3RA750-C           ü
    700 Light/Normal/Heavy 1321-3R850-C 1321-3RA850-C 1321-3R850-C 1321-3RA850-C           ü
    522 700 Normal 1321-3R850-C 1321-3RA850-C 1321-3R850-C 1321-3RA850-C   ü        
    Normal 1321-3RB400-C 1321-3RAB400-C     ü §       
    671 700 Heavy 1321-3RB400-C 1321-3RAB400-C     ü §       
    750 Heavy 1321-3R850-C 1321-3RA850-C 1321-3R850-C 1321-3RA850-C           ü
    800 Light/Normal/Heavy 1321-3R1000-C 1321-3RA1000-C 1321-3R1000-C 1321-3RA1000-C           ü
    560 Light/Normal/Heavy 1321-3R600-C 1321-3RA600-C 1321-3R600-C 1321-3RA600-C           ü § 
    597 800 Normal 1321-3R500-C 1321-3RA500-C     ü §       
    630 Light/Normal/Heavy 1321-3R600-C 1321-3RA600-C 1321-3R600-C 1321-3RA600-C           ü § 
    746 800 Heavy 1321-3R500-C 1321-3RA500-C     ü §       
    900 Light/Normal/Heavy 1321-3R600-C 1321-3RA600-C 1321-3R600-C 1321-3RA600-C           ü § 
    671 900 Normal 1321-3R500-C 1321-3RA500-C     ü §       
    Heavy 1321-3RA600-C 1321-3RA600-C     ü §       
    710 Light/Normal/Heavy 1321-3R600-C 1321-3RA600-C 1321-3R600-C 1321-3RA600-C           ü § 
    1000 Light/Normal/Heavy 1321-3R600-C 1321-3RA600-C 1321-3R600-C 1321-3RA600-C           ü § 
    746 1000 Normal 1321-3RA600-C 1321-3RA600-C     ü §       
    Heavy 1321-3R750-C 1321-3RA750-C     ü § ⋆       
    1100 Light/Normal 1321-3R750-C 1321-3RA750-C 1321-3R750-C 1321-3RA750-C           ü § 
    800 Light/Normal 1321-3R750-C 1321-3RA750-C 1321-3R750-C 1321-3RA750-C           ü § 
    850 Light/Normal 1321-3R750-C 1321-3RA750-C 1321-3R750-C 1321-3RA750-C           ü § 
    895 1200 Normal 1321-3R750-C 1321-3RA750-C     ü § ⋆       
    1250 Light/Normal 1321-3R750-C 1321-3RA750-C 1321-3R750-C 1321-3RA750-C           ü § 
    900 Light 1321-3R850-C 1321-3RA850-C 1321-3R850-C 1321-3RA850-C           ü § 
    933 1250 Normal 1321-3R750-C 1321-3RA750-C     ü §       
    1350 Light 1321-3R850-C 1321-3RA850-C 1321-3R850-C 1321-3RA850-C           ü § 
    1500 Light 1321-3R850-C 1321-3RA850-C 1321-3R850-C 1321-3RA850-C           ü ♠ 
    1000 Light 1321-3R850-C 1321-3RA850-C 1321-3R850-C 1321-3RA850-C           ü ♠ 
    2000 Light 1321-3R850-C 1321-3RA850-C 1321-3R850-C 1321-3RA850-C           ü ♠ 
    1400 Light 1321-3R850-C 1321-3RA850-C 1321-3R850-C 1321-3RA850-C           ü ♠ 
    ‡ Input line reactors were sized based on the NEC fundamental motor amps (PowerFlex 700H has an integral input reactor). Output line reactors were sized based on the VFD rated output currents.
    ⋆ 4% impedance.
    § Requires two output reactors wired in parallel.
    ♠ Requires three reactors wired in parallel.
    ♦ Light Duty refers to PowerFlex 755 drives only.

    Input and Output Reactors - 500…690V, 50/60 Hz, Three-Phase, 3% Impedance
    kW Hp Duty Input Line Reactor ‡  Output Reactor ‡  Used with PowerFlex Drive
    IP00
    (Open Style)
    IP11
    (NEMA/UL Type 1)
    IP00
    (Open Style)
    IP11
    (NEMA/UL Type 1)
    70 700 700H 700S 700L 753/755
    0.25 0.33 Heavy 1321-3R1-C 1321-3RA1-C 1321-3R1-B 1321-3RA1-B ü          
    0.37 0.5 Normal 1321-3R1-C 1321-3RA1-C 1321-3R1-B 1321-3RA1-B ü          
    Heavy 1321-3R1-C 1321-3RA1-C 1321-3R2-B 1321-3RA2-B   ü   ü    
    0.55 0.75 Heavy 1321-3R2-B 1321-3RA2-B 1321-3R2-B 1321-3RA2-B ü          
    0.75 1 Normal 1321-3R2-B 1321-3RA2-B 1321-3R2-B 1321-3RA2-B ü ü   ü   ü
    Heavy 1321-3R2-B 1321-3RA2-B 1321-3R4-D 1321-3RA4-D   ü   ü   ü
    1.1 1.5 Heavy 1321-3R2-A 1321-3RA2-A 1321-3R4-D 1321-3RA4-D ü          
    1.5 2 Normal 1321-3R4-C 1321-3RA4-C 1321-3R4-D 1321-3RA4-D ü          
    Heavy 1321-3R4-C 1321-3RA4-C 1321-3R4-C 1321-3RA4-C ü         ü
    Normal 1321-3R4-D 1321-3RA4-D 1321-3R4-D 1321-3RA4-D   ü   ü   ü
    Heavy 1321-3R4-D 1321-3RA4-D 1321-3R4-C 1321-3RA4-C   ü   ü   ü
    2.2 3 Normal 1321-3R4-C 1321-3RA4-C 1321-3R4-C 1321-3RA4-C ü ü   ü   ü
    Heavy 1321-3R4-C 1321-3RA4-C 1321-3R8-C 1321-3RA8-C ü ü   ü    
    4 5 Normal 1321-3R8-C 1321-3RA8-C 1321-3R8-C 1321-3RA8-C ü ü   ü   ü
    Heavy 1321-3R8-C 1321-3RA8-C 1321-3R12-C 1321-3RA12-C ü ü   ü   ü
    5.5 7.5 Normal 1321-3R12-C 1321-3RA12-C 1321-3R12-C 1321-3RA12-C ü ü   ü   ü
    Heavy 1321-3R12-C 1321-3RA12-C 1321-3R12-B 1321-3RA12-B ü ü   ü   ü
    7.5 10 Normal 1321-3R12-B 1321-3RA12-B 1321-3R12-B 1321-3RA12-B ü ü   ü   ü
    Heavy 1321-3R12-B 1321-3RA12-B 1321-3R18-B 1321-3RA18-B ü ü   ü   ü
    11 15 Normal 1321-3R18-B 1321-3RA18-B 1321-3R18-B 1321-3RA18-B ü ü   ü   ü
    Heavy 1321-3R18-B 1321-3RA18-B 1321-3R25-B 1321-3RA25-B ü ü   ü   ü
    15 20 Normal 1321-3R25-B 1321-3RA25-B 1321-3R25-B 1321-3RA25-B ü ü   ü   ü
    Heavy 1321-3R25-B 1321-3RA25-B 1321-3R35-C 1321-3RA35-C ü ü   ü   ü
    18.5 25 Normal 1321-3R35-C 1321-3RA35-C 1321-3R35-C 1321-3RA35-C ü ü   ü   ü
    Heavy 1321-3R35-C 1321-3RA35-C 1321-3R35-B 1321-3RA35-B ü ü   ü   ü
    22 30 Normal 1321-3R35-B 1321-3RA35-B 1321-3R35-B 1321-3RA35-B ü ü   ü   ü
    Heavy 1321-3R35-B 1321-3RA35-B 1321-3R45-B 1321-3RA45-B ü ü   ü   ü
    30 40 Normal 1321-3R45-B 1321-3RA45-B 1321-3R45-B 1321-3RA45-B ü ü   ü   ü
    Heavy 1321-3R45-B 1321-3RA45-B 1321-3R55-B 1321-3RA55-B ü ü   ü   ü
    37 50 Normal 1321-3R55-B 1321-3RA55-B 1321-3R55-B 1321-3RA55-B ü ü   ü   ü
    Heavy 1321-3R55-B 1321-3RA55-B 1321-3R80-B 1321-3RA80-B   ü   ü   ü
    45 60 Normal/Heavy 1321-3R80-B 1321-3RA80-B 1321-3R80-B 1321-3RA80-B   ü   ü   ü
    55 75 Normal/Heavy 1321-3R80-B 1321-3RA80-B 1321-3R80-B 1321-3RA80-B   ü   ü   ü
    75 100 Normal/Heavy 1321-3R100-B 1321-3RA100-B 1321-3R100-B 1321-3RA100-B   ü   ü   ü
    90 125 Normal/Heavy 1321-3R130-B 1321-3RA130-B 1321-3R130-B 1321-3RA130-B   ü   ü   ü
    110 150 Normal 1321-3R160-B 1321-3RA160-B 1321-3R160-B 1321-3RA160-B   ü   ü   ü
    Normal/Heavy 1321-3R200-C 1321-3RA200-C     ü      
    132 Heavy 1321-3RB250-C 1321-3RAB250-C     ü      
    149 200 Normal/Heavy 1321-3R200-B 1321-3RA200-B     ü      
    160 Normal/Heavy 1321-3RB250-C 1321-3RAB250-C     ü      
    187 250 Normal/Heavy 1321-3RB250-B 1321-3RAB250-B     ü      
    300 Heavy 1321-3RB320-B 1321-3RAB320-B 1321-3RB320-B 1321-3RAB320-B           ü
    200 Normal 1321-3RB250-C 1321-3RAB250-C     ü      
    Heavy 1321-3RB320-C 1321-3RAB320-C     ü      
    Heavy 1321-3R250-B 1321-3RA250-B 1321-3R250-B 1321-3RA250-B           ü
    350 Light/Normal/Heavy 1321-3RB400-B 1321-3RAB400-B 1321-3RB400-B 1321-3RAB400-B           ü
    250 Normal 1321-3RB320-C 1321-3RAB320-C     ü      
    Heavy 1321-3RB400-C 1321-3RAB400-C     ü      
    Normal/Heavy 1321-3RB320-B 1321-3RAB320-B 1321-3RB320-B 1321-3RAB320-B           ü
    261 350 Normal/Heavy 1321-3RB320-B 1321-3RAB320-B     ü      
    ‡ Input line reactors were sized based on the NEC fundamental motor amps (PowerFlex 700H has an integral input reactor). Output line reactors were sized based on the VFD rated output currents.

    Input and Output Reactors - 500…690V, 50/60 Hz, Three-Phase, 3% Impedance (continued)
    kW Hp Duty Input Line Reactor ‡  Output Reactor ‡  Used with PowerFlex Drive
    IP00
    (Open Style)
    IP11
    (NEMA/UL Type 1)
    IP00
    (Open Style)
    IP11
    (NEMA/UL Type 1)
    70 700 700H 700S 700L 753/755
    298 400 Normal/Heavy 1321-3RB400-B 1321-3RAB400-B     ü      
    400 Light/Normal/Heavy 1321-3RB400-B 1321-3RAB400-B 1321-3RB400-B 1321-3RAB400-B           ü
    300 Heavy 1321-3RB400-B 1321-3RAB400-B 1321-3RB400-B 1321-3RAB400-B           ü
    450 Light/Normal/Heavy 1321-3R500-B 1321-3RA500-B 1321-3R500-B 1321-3RA500-B           ü
    315 Normal 1321-3RB400-C 1321-3RAB400-C     ü      
    Heavy 1321-3R500-C 1321-3RA500-C     ü      
    Light/Normal 1321-3RB400-B 1321-3RAB400-B 1321-3RB400-B 1321-3RAB400-B           ü
    336 450 Normal 1321-3RB400-B 1321-3RAB400-B     ü      
    Normal 1321-3R500-B 1321-3RA500-B     ü      
    Heavy 1321-3RB400-B 1321-3RAB400-B     ü      
    500 Light/Normal/Heavy 1321-3R600-B 1321-3RA600-B 1321-3R600-B 1321-3RA600-B           ü
    355 Normal 1321-3R500-C 1321-3RA500-C     ü      
    Heavy 1321-3R600-C 1321-3RA600-C     ü      
    Light/Normal/Heavy 1321-3R500-B 1321-3RA500-B 1321-3R500-B 1321-3RA500-B           ü
    373 500 Normal/Heavy 1321-3R500-B 1321-3RA500-B     ü      
    550 Light 1321-3R600-B 1321-3RA600-B 1321-3R600-B 1321-3RA600-B           ü
    375 Heavy 1321-3R500-B 1321-3RA500-B 1321-3R500-B 1321-3RA500-B           ü
    400 Normal 1321-3R500-C 1321-3RA500-C     ü      
    Light/Normal/Heavy 1321-3R500-B 1321-3RA500-B 1321-3R500-B 1321-3RA500-B           ü
    448 600 Normal 1321-3R600-B 1321-3RA600-B     ü      
    600 Normal/Heavy 1321-3R600-B 1321-3RA600-B 1321-3R600-B 1321-3RA600-B           ü
    450 Normal/Heavy 1321-3R600-C 1321-3RA600-C     ü      
    Light/Normal 1321-3R600-B 1321-3RA600-B 1321-3R600-B 1321-3RA600-B           ü
    485 650 Heavy 1321-3RB320-B 1321-3RAB320-B     ü §       
    500 Normal 1321-3R600-C 1321-3RA600-C     ü      
    Heavy 1321-3R750-C 1321-3RA750-C     ü      
    Light/Normal/Heavy 1321-3R600-B 1321-3RA600-B 1321-3R600-B 1321-3RA600-B           ü
    522 700 Normal 1321-3RB320-B 1321-3RAB320-B     ü §       
    Heavy 1321-3RB400-C 1321-3RAB400-C     ü §       
    700 Light/Normal/Heavy 1321-3R750-B 1321-3RA750-B 1321-3R750-B 1321-3RA750-B           ü
    530 Light 1321-3R600-B 1321-3RA600-B 1321-3R600-B 1321-3RA600-B           ü
    560 Normal 1321-3R750-C 1321-3RA750-C     ü      
    Heavy 1321-3RB400-C 1321-3RAB400-C     ü §       
    Normal/Heavy 1321-3R750-B 1321-3RA750-B 1321-3R750-B 1321-3RA750-B           ü
    750 Heavy 1321-3R750-B 1321-3RA750-B 1321-3R750-B 1321-3RA750-B           ü
    597 800 Normal 1321-3RB400-C 1321-3RAB400-C     ü §       
    800 Light/Normal/Heavy 1321-3R850-B 1321-3RA850-B 1321-3R850-B 1321-3RA850-B           ü
    630 Normal 1321-3RB400-C 1321-3RAB400-C     ü §       
    Heavy 1321-3R500-C 1321-3RA500-C     ü §       
    Light/Normal/Heavy 1321-3R750-B 1321-3RA750-B 1321-3R750-B 1321-3RA750-B           ü
    671 900 Normal 1321-3RB400-B 1321-3RAB400-B     ü §       
    Heavy 1321-3R1000-C 1321-3RA1000-C     ü      
    900 Light/Normal/Heavy 1321-3R850-B 1321-3RA850-B 1321-3R850-B 1321-3RA850-B           ü
    710 Normal 1321-3R500-C 1321-3RA500-C     ü §       
    Light/Normal/Heavy 1321-3R850-B 1321-3RA850-B 1321-3R850-B 1321-3RA850-B           ü
    950 Light/Normal 1321-3R1000-B 1321-3RA1000-B 1321-3R1000-B 1321-3RA1000-B           ü
    746 1000 Normal 1321-3R1000-C 1321-3RA1000-C     ü      
    Heavy 1321-3R1000-B 1321-3RA1000-B     ü      
    continued
    ‡ Input line reactors were sized based on the NEC fundamental motor amps (PowerFlex 700H has an integral input reactor). Output line reactors were sized based on the VFD rated output currents.
    § Requires two reactors wired in parallel.

    Input and Output Reactors - 500…690V, 50/60 Hz, Three-Phase, 3% Impedance (continued)
    kW Hp Duty Input Line Reactor ‡  Output Reactor ‡  Used with PowerFlex Drive
    IP00
    (Open Style)
    IP11
    (NEMA/UL Type 1)
    IP00
    (Open Style)
    IP11
    (NEMA/UL Type 1)
    70 700 700H 700S 700L 753/755
    750 Normal 1321-3R850-B 1321-3RA850-B 1321-3R850-B 1321-3RA850-B           ü
    800 Normal 1321-3R500-C 1321-3RA500-C     ü §       
    Heavy 1321-3R600-C 1321-3RA600-C     ü §       
    Light/Normal/Heavy 1321-3R1000-B 1321-3RA1000-B 1321-3R1000-B 1321-3RA1000-B           ü
    1000 Light/Normal 1321-3R1000-B 1321-3RA1000-B 1321-3R1000-B 1321-3RA1000-B           ü
    821 1100 Normal 1321-3R1000-B 1321-3RA1000-B     ü      
    Heavy 1321-3R600-B 1321-3RA600-B     ü §       
    1100 Light 1321-3R600-B 1321-3RA600-B 1321-3R600-B 1321-3RA600-B           ü § 
    850 Light 1321-3R1000-B 1321-3RA1000-B 1321-3R1000-B 1321-3RA1000-B           ü
    900 Normal/Heavy 1321-3R600-C 1321-3RA600-C     ü §       
    Light/Normal 1321-3R600-B 1321-3RA600-B 1321-3R600-B 1321-3RA600-B           ü § 
    970 1300 Normal 1321-3R600-B 1321-3RA600-B     ü §       
    1000 Normal 1321-3R600-C 1321-3RA600-C     ü §       
    Heavy 1321-3R750-C 1321-3RA750-C     ü §       
    Light 1321-3R600-B 1321-3RA600-B 1321-3R600-B 1321-3RA600-B           ü § 
    1100 Normal 1321-3R750-C 1321-3RA750-C     ü §       
    Light/Normal 1321-3R600-B 1321-3RA600-B 1321-3R600-B 1321-3RA600-B           ü ♠ 
    1200 Light 1321-3R600-B 1321-3RA600-B 1321-3R600-B 1321-3RA600-B           ü ♠ 
    1500 Light/Normal 1321-3R600-B 1321-3RA600-B 1321-3R600-B 1321-3RA600-B           ü ♠ 
    1500 Light 1321-3R600-B 1321-3RA600-B 1321-3R600-B 1321-3RA600-B           ü ♠ 
    ‡ Input line reactors were sized based on the NEC fundamental motor amps (PowerFlex 700H has an integral input reactor). Output line reactors were sized based on the VFD rated output currents.
    § Requires two reactors wired in parallel.
    ♠ Requires three reactors wired in parallel.

    Input and Output Reactors - 500…690V, 50/60 Hz, Three-Phase, 5% Impedance
    kW Hp Duty Input Line Reactor ‡  Output Reactor ‡  Used with PowerFlex Drive
    IP00
    (Open Style)
    IP11
    (NEMA/UL Type 1)
    IP00
    (Open Style)
    IP11
    (NEMA/UL Type 1)
    70 700 700H 700S 700L 753/755
    0.25 0.33 Heavy 1321-3R1-A 1321-3RA1-A 1321-3R1-B 1321-3RA1-B ü          
    0.37 0.5 Normal 1321-3R1-B 1321-3RA1-B 1321-3R1-B 1321-3RA1-B ü          
    0.37 0.5 Heavy 1321-3R1-B 1321-3RA1-B 1321-3R2-C 1321-3RA2-C   ü   ü    
    0.55 0.75 Heavy 1321-3R2-C 1321-3RA2-C 1321-3R2-C 1321-3RA2-C ü          
    0.75 1 Normal 1321-3R2-C 1321-3RA2-C 1321-3R2-C 1321-3RA2-C ü ü   ü   ü
    Heavy 1321-3R2-C 1321-3RA2-C 1321-3R4-D 1321-3RA4-D   ü   ü   ü
    1.1 1.5 Heavy 1321-3R2-B 1321-3RA2-B 1321-3R4-D 1321-3RA4-D ü ü   ü    
    1.5 2 Normal/Heavy 1321-3R4-D 1321-3RA4-D 1321-3R4-D 1321-3RA4-D ü ü   ü   ü
    2.2 3 Normal 1321-3R4-D 1321-3RA4-D 1321-3R4-D 1321-3RA4-D ü ü   ü   ü
    Heavy 1321-3R4-D 1321-3RA4-D 1321-3R8-D 1321-3RA8-D ü ü   ü   ü
    4 5 Normal 1321-3R8-D 1321-3RA8-D 1321-3R8-D 1321-3RA8-D ü ü   ü   ü
    Heavy 1321-3R8-D 1321-3RA8-D 1321-3R12-C 1321-3RA12-C ü ü   ü   ü
    5.5 7.5 Normal/Heavy 1321-3R12-C 1321-3RA12-C 1321-3R12-C 1321-3RA12-C ü ü   ü   ü
    7.5 10 Normal 1321-3R12-C 1321-3RA12-C 1321-3R12-C 1321-3RA12-C ü ü   ü   ü
    Heavy 1321-3R12-C 1321-3RA12-C 1321-3R18-C 1321-3RA18-C ü ü   ü   ü
    11 15 Normal 1321-3R18-C 1321-3RA18-C 1321-3R18-C 1321-3RA18-C ü ü   ü   ü
    Heavy 1321-3R18-C 1321-3RA18-C 1321-3R25-C 1321-3RA25-C ü ü   ü   ü
    15 20 Normal 1321-3R25-C 1321-3RA25-C 1321-3R25-C 1321-3RA25-C ü ü   ü   ü
    Heavy 1321-3R25-C 1321-3RA25-C 1321-3R35-C 1321-3RA35-C ü ü   ü   ü
    18.5 25 Normal/Heavy 1321-3R35-C 1321-3RA35-C 1321-3R35-C 1321-3RA35-C ü ü   ü   ü
    22 30 Normal 1321-3R35-C 1321-3RA35-C 1321-3R35-C 1321-3RA35-C ü ü   ü   ü
    Heavy 1321-3R35-C 1321-3RA35-C 1321-3R45-C 1321-3RA45-C ü ü   ü   ü
    30 40 Normal 1321-3R45-C 1321-3RA45-C 1321-3R45-C 1321-3RA45-C ü ü   ü   ü
    Heavy 1321-3R45-C 1321-3RA45-C 1321-3R55-C 1321-3RA55-C ü ü   ü   ü
    37 50 Normal 1321-3R55-C 1321-3RA55-C 1321-3R55-C 1321-3RA55-C ü ü   ü   ü
    Heavy 1321-3R55-C 1321-3RA55-C 1321-3R80-C 1321-3RA80-C   ü   ü   ü
    45 60 Normal/Heavy 1321-3R80-C 1321-3RA80-C 1321-3R80-C 1321-3RA80-C   ü   ü   ü
    55 75 Normal/Heavy 1321-3R80-C 1321-3RA80-C 1321-3R80-C 1321-3RA80-C   ü   ü   ü
    75 100 Normal/Heavy 1321-3R100-C 1321-3RA100-C 1321-3R100-C 1321-3RA100-C   ü   ü   ü
    90 125 Normal/Heavy 1321-3R130-C 1321-3RA130-C 1321-3R130-C 1321-3RA130-C   ü   ü   ü
    110 150 Normal 1321-3R160-C 1321-3RA160-C 1321-3R160-C 1321-3RA160-C   ü   ü   ü
    Heavy 1321-3R160-C 1321-3RA160-C     ü ⋆       
    Normal 1321-3R200-C 1321-3RA200-C     ü ∆       
    149 200 Normal 1321-3R200-B 1321-3RA200-B     ü ⋆       
    Heavy 1321-3R200-C 1321-3RA200-C     ü ⋆       
    187 250 Normal/Heavy 1321-3RB250-C 1321-3RAB250-C     ü ⋆       
    300 Heavy 1321-3RB320-C 1321-3RAB320-C 1321-3RB320-C 1321-3RAB320-C           ü
    200 Heavy 1321-3R250-C 1321-3RA250-C 1321-3R250-C 1321-3RA250-C           ü
    350 Light/Normal/Heavy 1321-3RB400-C 1321-3RAB400-C 1321-3RB400-C 1321-3RAB400-C           ü
    250 Normal/Heavy 1321-3RB320-C 1321-3RAB320-C 1321-3RB320-C 1321-3RAB320-C           ü
    261 350 Normal/Heavy 1321-3RB320-C 1321-3RAB320-C     ü ⋆       
    400 Light/Normal/Heavy 1321-3RB400-C 1321-3RAB400-C 1321-3RB400-C 1321-3RAB400-C           ü
    298 400 Normal/Heavy 1321-3RB400-C 1321-3RAB400-C     ü ⋆       
    continued
    ‡ Input line reactors were sized based on the NEC fundamental motor amps (PowerFlex 700H has an integral input reactor). Output line reactors were sized based on the VFD rated output currents.
    ⋆ 4% impedance.
    ∆ 3% impedance.

    Input and Output Reactors - 500…690V, 50/60 Hz, Three-Phase, 5% Impedance (continued)
    kW Hp Duty Input Line Reactor ‡  Output Reactor ‡  Used with PowerFlex Drive
    IP00
    (Open Style)
    IP11
    (NEMA/UL Type 1)
    IP00
    (Open Style)
    IP11
    (NEMA/UL Type 1)
    70 700 700H 700S 700L 753/755
    300 Heavy 1321-3RB400-C 1321-3RAB400-C 1321-3RB400-C 1321-3RAB400-C           ü
    315 Light/Normal 1321-3RB400-C 1321-3RAB400-C 1321-3RB400-C 1321-3RAB400-C           ü
    450 Light/Normal/Heavy 1321-3R500-C 1321-3RA500-C 1321-3R500-C 1321-3RA500-C           ü
    336 450 Normal 1321-3R500-C 1321-3RA500-C     ü ⋆       
    Heavy 1321-3RB400-C 1321-3RAB400-C     ü      
    500 Light/Normal 1321-3R600-C 1321-3RA600-C 1321-3R600-C 1321-3RA600-C           ü
    355 Light/Normal/Heavy 1321-3R500-C 1321-3RA500-C 1321-3R500-C 1321-3RA500-C           ü
    373 500 Normal/Heavy 1321-3R500-C 1321-3RA500-C     ü      
    550 Light 1321-3R600-C 1321-3RA600-C 1321-3R600-C 1321-3RA600-C           ü
    375 Heavy 1321-3R500-C 1321-3RA500-C 1321-3R500-C 1321-3RA500-C           ü
    400 Light/Normal/Heavy 1321-3R500-C 1321-3RA500-C 1321-3R500-C 1321-3RA500-C           ü
    448 600 Normal 1321-3R600-C 1321-3RA600-C     ü ⋆       
    600 Normal/Heavy 1321-3R600-C 1321-3RA600-C 1321-3R600-C 1321-3RA600-C           ü
    450 Light/Normal/Heavy 1321-3R600-C 1321-3RA600-C 1321-3R600-C 1321-3RA600-C           ü
    485 650 Heavy 1321-3RB320-C 1321-3RAB320-C     ü ⋆ §       
    500 Heavy 1321-3R600-C 1321-3RA600-C 1321-3R600-C 1321-3RA600-C           ü
    522 700 Normal 1321-3RB320-C 1321-3RAB320-C     ü ⋆ §       
    Heavy 1321-3RB400-C 1321-3RAB400-C     ü ⋆ §       
    700 Light/Normal/Heavy 1321-3R750-C 1321-3RA750-C 1321-3R750-C 1321-3RA750-C           ü
    530 Light 1321-3R600-C 1321-3RA600-C 1321-3R600-C 1321-3RA600-C           ü
    750 Heavy 1321-3R750-C 1321-3RA750-C 1321-3R750-C 1321-3RA750-C           ü
    560 Normal/Heavy 1321-3R750-C 1321-3RA750-C 1321-3R750-C 1321-3RA750-C           ü
    597 800 Normal 1321-3RB400-C 1321-3RAB400-C     ü ⋆ §       
    800 Light/Normal/Heavy 1321-3R850-C 1321-3RA850-C 1321-3R850-C 1321-3RA850-C           ü
    630 Light/Normal/Heavy 1321-3R750-C 1321-3RA750-C 1321-3R750-C 1321-3RA750-C           ü
    671 900 Normal 1321-3RB400-C 1321-3RAB400-C     ü §       
    Heavy 1321-3R500-C 1321-3RA500-C     ü ⋆ §       
    900 Light/Normal/Heavy 1321-3R850-C 1321-3RA850-C 1321-3R850-C 1321-3RA850-C           ü
    950 Light/Normal 1321-3R1000-C 1321-3RA1000-C 1321-3R1000-C 1321-3RA1000-C           ü
    710 Light/Normal/Heavy 1321-3R850-C 1321-3RA850-C 1321-3R850-C 1321-3RA850-C           ü
    746 1000 Normal 1321-3R500-C 1321-3RA500-C     ü ⋆ §       
    Heavy 1321-3R1000-C 1321-3RA1000-C     ü ⋆       
    750 Normal 1321-3R850-C 1321-3RA850-C 1321-3R850-C 1321-3RA850-C           ü
    1000 Light/Normal 1321-3R1000-C 1321-3RA1000-C 1321-3R1000-C 1321-3RA1000-C           ü
    800 Light/Normal/Heavy 1321-3R1000-C 1321-3RA1000-C 1321-3R1000-C 1321-3RA1000-C           ü
    821 1100 Normal 1321-3R1000-C 1321-3RA1000-C     ü ⋆       
    Heavy 1321-3R600-C 1321-3RA600-C     ü ⋆ §       
    1100 Light 1321-3R600-C 1321-3RA600-C 1321-3R600-C 1321-3RA600-C           ü § 
    850 Light 1321-3R1000-C 1321-3RA1000-C 1321-3R1000-C 1321-3RA1000-C           ü
    900 Light/Normal 1321-3R600-C 1321-3RA600-C 1321-3R600-C 1321-3RA600-C           ü § 
    970 1300 Normal 1321-3R600-C 1321-3RA600-C     ü ⋆ §       
    1000 Light 1321-3R600-C 1321-3RA600-C 1321-3R600-C 1321-3RA600-C           ü § 
    1100 Light/Normal 1321-3R600-C 1321-3RA600-C 1321-3R600-C 1321-3RA600-C           ü ♠ 
    1200 Light 1321-3R600-C 1321-3RA600-C 1321-3R600-C 1321-3RA600-C           ü ♠ 
    1500 Light/Normal 1321-3R600-C 1321-3RA600-C 1321-3R600-C 1321-3RA600-C           ü ♠ 
    1500 Light 1321-3R600-C 1321-3RA600-C 1321-3R600-C 1321-3RA600-C           ü ♠ 
    ‡ Input line reactors were sized based on the NEC fundamental motor amps (PowerFlex 700H has an integral input reactor). Output line reactors were sized based on the VFD rated output currents.
    ⋆ 4% impedance.
    § Requires two output reactors wired in parallel.
    ♠ Requires three reactors wired in parallel.

    For details, refer to the PowerFlex 700H Technical Data.

    Certifications
    c-UL Listed to UL508C and CAN/CSA-C2.2 No. 14-M91
    TÜV ATEX EC-Type-Examination Certificate TUV 06 ATEX 7407 for directive 94/9/EC: Safe turn off of certified ATEX motors used in Group II Category (2) GD potentially explosive atmospheres
    CE Certified by Rockwell Automation to be in conformity with the essential requirements of the applicable European Directives and the standards referenced below have been applied:
    Low Voltage Directive: 2006/95/EC
    EN 50178 Electronic Equipment for use in Power Installations
    EMC Directive: 2004/108/EC
    EN 61800-3 Adjustable Speed electrical power drive systems - Part 3: EMC requirements and specific test methods
    C-Tick Certified by Rockwell Automation to be in conformity with the requirements of the applicable Australian legislation and the standards referenced below:
    EN 61800-3
    The drive is designed to meet the following applicable requirements: NFPA 70 - US National Electrical Code
    NEMA ICS 7.1 - Safety Standards for Construction and Guide for Selection, Installation, and Operation of Adjustable Speed Drive Systems
    IEC 146 - International Electrical Code

    Environmental Specifications
    Category Specification
    Altitude: 1000 m (3300 ft) maximum without derating. Derate the drive by 1% for every 100 m (328 ft.) above 1000 m (3300 ft.).
    Maximum Surrounding Air Temperature without Derating: Based on drive rating
    Storage Temperature (All Const.): -40…60 °C (-40…140 °F)
    Atmosphere: Important: Drive must not be installed in an area where the ambient atmosphere contains volatile or corrosive gas, vapors or dust. If the drive is not going to be installed for a period of time, it must be stored in an area where it will not be exposed to a corrosive atmosphere.
    Relative Humidity: 5 to 95% non-condensing
    Shock: 15 g peak for 11 ms duration (±1.0 ms)
    Vibration: 1 g peak, 2 mm (0.0787 in.) displacement
    Sound:
        Frame 9
        Frame 10
        Frame 13
    Sound Level/Background Noise Level
    78/49 dB
    77/49 dB
    76/46 dB

    Technical Specifications
    Category Specification
    Protection AC Input Overvoltage Trip
        380…400V:
        480V:
        500V:
        600V:
        690V:

    611V AC
    611V AC
    611V AC
    806V AC
    806V AC
    AC Input Undervoltage Trip
        380…400V:
        480V:
        500V:
        600V:
        690V:

    235VAC
    235V AC
    235V AC
    326V AC
    326V AC
    Bus Overvoltage Trip
        380…400V:
        480V:
        500V:
        600V:
        690V:

    911V DC
    911V DC
    911V DC
    1200V DC
    1200V DC
    Bus Undervoltage Shutoff/Fault
        380…400V:
        480V:
        500V:
        600V:
        690V:

    333V DC
    333V DC
    333V DC
    461V DC
    461V DC
    Nominal Bus Voltage (Full Load)
        380…400V:
        480V:
        500V:
        600V:
        690V:

    517V DC
    621V DC
    645V DC
    776V DC
    890V DC
    Heat Sink Thermistor: Monitored by microprocessor overtemp trip
    Drive Overcurrent Trip
        Hardware Current Limit:

    360% of rated Heavy Duty current (typical)
    Line transients: up to 6000 volts peak per IEEE C62.41-1991
    Control Logic Noise Immunity: Showering arc transients up to 1500V peak
    Power Ride-Thru: 15 milliseconds at full load
    Logic Control Ride-Thru: 0.5 seconds minimum, 2 seconds typical
    Ground Fault Trip: Phase-to-ground on drive output
    Short Circuit Trip: Phase-to-phase on drive output
    Electrical Efficiency: 97.5% at rated amps, nominal line voltage
    AC Input Voltage Tolerance: ±10%
    Input Frequency Tolerance: 47…63 Hz
    Input Phases: Three-phase input provides full rating for all drives. Single-phase operation provides 50% of rated current.
    Displacement Power Factor: 0.98 across entire speed range
    Maximum Short Circuit Rating: Less than or equal to 200,000 Amps Symmetrical
    Actual Short Circuit Rating: Determined by AIC rating of installed fuse/circuit breaker.
    Maximum Drive to Motor Power Ratio: Recommended not greater than 2:1 ratio.
    Control Method: Sine coded PWM with programmable carrier frequency. Ratings apply to all drives.
    Carrier Frequency: 1…6 kHz. Drive rating based on 4 kHz.
    Output Voltage: 0 to rated motor voltage
    Output Frequency: 0…320 Hz
    Frequency Accuracy
        Digital Input:
        Analog Input:

    Within ±0.01% of set output frequency.
    Within ±0.4% of maximum output frequency.
    Frequency Control: Speed Regulation with Slip Compensation
    0.5% of base speed across 40:1 speed range, 40:1 operating range
    Selectable Motor Control: Sensorless Vector with full tuning. Standard V/Hz with full custom capability.
    Stop Modes: Multiple programmable stop modes including - Ramp, Coast, DC-Brake, Ramp-to-Hold and S-curve.
    Accel/Decel: Two independently programmable accel and decel times. Each time may be programmed from 0…3276.7 seconds in 0.1 second increments.
    S-Curve Time: 0-100% of accel/decel time
    Intermittent Overload: 110% Overload capability for up to 1 minute
    150% Overload capability for up to 2 seconds
    Current Limit Capability: Proactive Current Limit programmable from 20 to 160% of rated output current. Independently programmable proportional gain.
    Electronic Motor Overload Protection: Class 10 protection with speed sensitive response. Investigated by U.L. to comply with N.E.C. Article 430. U.L. File E59272, volume 12.
      

    For detailed dimensions and weights, refer to the PowerFlex 700H Technical Data.

    Dimensions are in mm (in.) - weights are in kg (lb)

    Click to enlarge - dim_outline


    IP21, NEMA Type 1
    Frame H W D Weight
    9 1150.0 (45.28) 480.0 (18.90) 363.3 (14.32) Refer to the PowerFlex 700H Technical Data
    10 2275.0 (89.57) 597.0 (23.50) 632.5 (24.90)
    11 2275.0 (89.57) 797.0 (31.38) 621.7 (24.48)
    12 2275.0 (89.57) 1196.0 (47.09) 632.5 (24.90)
    13 2275.0 (89.57) 1412.0 (55.59) ⋆  620.0 (24.41)
    14 (1500A) 2275.0 (89.57) 2397.0 (94.37) 620.0 (24.41)
    14 (above 1500A) 2275.0 (89.57) 2800.0 (110.24) 620.0 (24.41)
    14 (DC Input) 2270.0 (89.37) 1597.0 (62.87) 620.0 (24.41)
    ⋆ Width for 400/480V AC (540/650V DC) 1300 and 1450A is 1600.0 (62.99).