PowerFlex 4-Class Options

Human Interface Modules and Accessories
Description Cat. No. Used with PowerFlex Drive
4M 4 40 40P 400
Remote (Panel Mount) LCD Display, Digital Speed Control, CopyCat Capable. Includes 2.0 meter cable. IP66, NEMA Type 4X/12 - Indoor Use Only. 22-HIM-C2S ♣  ü ü ü ü ü
Remote Handheld, LCD Display, Full Numeric Keypad, Digital Speed Control, CopyCat Capable. Includes 1.0 meter cable. IP30, NEMA Type 1. Panel mount with optional Bezel Kit. 22-HIM-A3 ü ü ü ü ü
Bezel Kit. Panel Mount for LCD Display, Remote Handheld Unit. IP30, NEMA Type 1. Includes a 22-RJ45CBL-C20 cable. 22-HIM-B1 ü ü ü ü ü
DSI HIM Cable (DSI HIM to RJ45 cable)            
1.0 Meter (3.3 Feet) 22-HIM-H10 ü ü ü ü ü
2.9 Meter (9.51 Feet) 22-HIM-H30 ü ü ü ü ü
♣ The 22-HIM-C2S is smaller than the 22-HIM-C2 and cannot be used as a direct replacement.

Safety Options
Description Cat. No. Used with PowerFlex Drive
4M 4 40 40P 400
DriveGuard Safe Torque-Off 20A-DG01       ü  
  

Other Options
Description Cat. No. Used with PowerFlex Drive
4M 4 40 40P 400
Auxiliary Relay Board - Expands drive output capabilities - Frames D…H only. AK-U9-RLB1         ü
  

Terminators
Description ⋆  Cat. No. Used with PowerFlex Drive
4M 4 40 40P 400
for use with 3.7 kW (5 Hp) & below drives 1204-TFA1 ü ü ü ü ü
for use with 1.5 kW (2 Hp) & up drives 1204-TFB2 ü ü ü ü ü
⋆ Refer to Appendix A of publication Drives-IN001 for selection information.

Reflected Wave Reduction Modules w/Common Mode Choke
Description ⋆  Cat. No. Used with PowerFlex Drive
4M 4 40 40P 400
17A with Common Mode Choke 1204-RWC-17-A ü ü ü ü ü
⋆ Refer to Appendix A of publication Drives-IN001 for selection information.

Reflected Wave Reduction Modules
Voltage ND kW ND Hp Cat. No. Used with PowerFlex Drive
4M 4 40 40P 400
380… 480V AC 2.2…4 3…5 1321-RWR8-DP ü ü ü ü ü
4 5 1321-RWR12-DP ü   ü ü ü
5.5 7.5 1321-RWR18-DP ü   ü ü ü
7.5 10 1321-RWR25-DP ü   ü ü ü
11 15 1321-RWR25-DP ü   ü ü ü
15 20 1321-RWR35-DP         ü
18.5 25 1321-RWR45-DP         ü
22 30 1321-RWR55-DP         ü
30 40 1321-RWR80-DP         ü
37 50 1321-RWR80-DP         ü
45 60 1321-RWR100-DP         ü
55 75 1321-RWR130-DP         ü
75 100 1321-RWR160-DP         ü
90 125 1321-RWR200-DP         ü
110 150 1321-RWR250-DP         ü
149 200 1321-RWR320-DP         ü
187 250 1321-RWR320-DP         ü
500… 600V AC 4 5 1321-RWR8-EP     ü ü  
5.5 7.5 1321-RWR12-EP     ü ü  
7.5 10 1321-RWR18-EP     ü ü  
11 15 1321-RWR25-EP     ü ü  
  

Communication Option Kits
Description Cat. No. Used with PowerFlex Drive
4M 4 40 40P 400
BACnet® MS/TP RS485 Communication Adapter 22-COMM-B   ü §  ü ∆    ü
ControlNet™ Communication Adapter 22-COMM-C ü §  ü §  ü ∆  ü ∆  ü
DeviceNet™ Communication Adapter 22-COMM-D ü §  ü §  ü ∆  ü ∆  ü
EtherNet/IP™ Communication Adapter 22-COMM-E ü §  ü §  ü ∆  ü ∆  ü
LonWorks® Communication Adapter 22-COMM-L   ü §  ü ∆  ü ∆  ü
PROFIBUS™ DP Communication Adapter 22-COMM-P ü § ‡  ü § ‡  ü ∆  ü ∆  ü
Serial Converter Module (RS485 to RS232). Provides serial communication via DF1 protocol for use with DriveExplorer and DriveExecutive™ software. Includes DSI to RS232 serial converter, 1203-SFC serial cable, 22-RJ45CBL-C20 cable, and DriveExplorer Lite CD. 22-SCM-232 ü ü ü ü ü
Serial Cable. 2.0 meter with a locking low profile connector. Connects the serial converter to a 9-pin sub-miniature D female computer connector. 1203-SFC ü ü ü ü ü
Serial Null Modem Adapter. Use when connecting the serial converter to DriveExplorer on a handheld PC. 1203-SNM ü ü ü ü ü
Universal Serial Bus™ (USB) Converter includes 2m USB, 20-HIM-H10 & 22-HIM-H10 Cables 1203-USB ü ü ü ü ü
DSI Cable. 2.0 meter RJ45 to RJ45 cable, male to male connectors. 22-RJ45CBL-C20 ü ü ü ü ü
Splitter Cable. RJ45 one to two port splitter cable. AK-U0-RJ45-SC1 ü ü ü ü ü
Terminal Block. RJ45 two position terminal block (6 pieces) with two 120 Ohm terminating resistors (loose). AK-U0-RJ45-TB2P ü ü ü ü ü
Terminating Resistors. 120 Ohm resistor embedded in an RJ45 connector (2 pieces). AK-U0-RJ45-TR1 ü ü ü ü ü
DSI External Communications Kit. External mounting kit for 22-COMM Communication Adapters. 22-XCOMM-DC-BASE ü ü ü ü ü
External Communications Kit Power Supply
Optional 100…240V AC Power Supply for External DSI Communications Kit.
20-XCOMM-AC-PS1 ü ü ü ü ü
PowerFlex Compact I/O DSI/Modbus Communications Module 1769-SM2 ü ü ü ü ü
Serial Flash Firmware Kit
Updates drive firmware via computer.
AK-U9-FLSH1         ü
Communication Adapter Cover
Houses the Communication Adapter for B & C Frame drives. Note: Cover adds 25 mm (0.98 in.) to the overall depth of the drive.
           
Frame B Drive (PowerFlex 40) 22B-CCB     ü ♦     
Frame C Drive (PowerFlex 40) 22B-CCC     ü ♦     
Frame C Drive (PowerFlex 400) 22C-CCC         ü ♦ 
Frame B Drive (PowerFlex 40P) 22D-CCB       ü ♦   
Frame C Drive (PowerFlex 40P) 22D-CCC       ü ♦   
‡ When a 22-COMM-P adapter is configured for multi-drive mode, a PowerFlex 40, 40P or 400 drive must be used as a master drive on the network.
§ PowerFlex 4 & 4M drives require External DSI Communication Kits. Communication Adapters cannot be drive mounted.
∆ Requires a Communication Adapter Cover when used with Frame B & C PowerFlex 40/40P drives or Frame C PowerFlex 400 drives.
♦ If IP30, NEMA/UL Type 1 is required, a 22-JBCB (Frame B drives) or 22-JBCC (Frame C drives) must also be ordered.

IP30, NEMA/UL Type 1 Conversion Kit
Description Frame Cat. No. Used with PowerFlex Drive
4M 4 40 40P 400
Converts IP20 drive to IP30, NEMA/UL Type 1 enclosure. Includes conduit box, mounting screws and plastic top panel. A 22-JBAA   ü      
B 22-JBAB   ü ü ü  
C 22-JBAC     ü ü ü
Converts IP20 drive to IP30, NEMA/UL Type 1 enclosure. Includes communication option conduit box, mounting screws and plastic top panel. B 22-JBCB     ü ü  
C 22-JBCC     ü ü ü
  

Dynamic Brakes Resistors
Drive Rating Minimum Resistance Resistance ♠  Cat. No. ▶  Used with PowerFlex Drive
Voltage kW Hp Ohms ±10% Ohms ±5% 4M 4 40 40P 400
100…120V, 50/60 Hz,
Single -Phase
0.2 0.25 48 91 AK-R2-091P500   ü      
0.4 0.5 48 91 AK-R2-091P500   ü ü    
0.75 1 48 91 AK-R2-091P500   ü ü    
1.1 1.5 48 91 AK-R2-091P500     ü    
200…240V, 50/60 Hz,
Single-Phase
0.2 0.25 48 91 AK-R2-091P500   ü      
0.4 0.5 48 91 AK-R2-091P500   ü ü    
0.75 1 48 91 AK-R2-091P500   ü ü    
1.5 2 48 91 AK-R2-091P500   ü ü    
2.2 3 32 47 AK-R2-047P500     ü    
200…240V, 50/60 Hz,
Three-Phase
0.2 0.25 48 91 AK-R2-091P500   ü      
0.4 0.5 48 91 AK-R2-091P500   ü ü ü  
0.75 1 48 91 AK-R2-091P500   ü ü ü  
1.5 2 48 91 AK-R2-091P500   ü ü ü  
2.2 3 32 47 AK-R2-047P500   ü ü ü  
3.7 5 19 47 AK-R2-047P500   ü ü ü  
5.5 7.5 13 30 AK-R2-030P1K2 ü   ü ü  
7.5 10 10 30 AK-R2-030P1K2 ü   ü ü  
380…480V, 50/60 Hz,
Three-Phase
0.4 0.5 97 360 AK-R2-360P500   ü ü ü  
0.75 1 97 360 AK-R2-360P500   ü ü ü  
1.5 2 97 360 AK-R2-360P500   ü ü ü  
2.2 3 97 120 AK-R2-120P1K2   ü ü ü  
4.0 5 77 120 AK-R2-120P1K2   ü ü ü  
5.5 7.5 55 120 AK-R2-120P1K2 ü   ü ü  
7.5 10 39 120 AK-R2-120P1K2 ü   ü ü  
11 15 24 120 AK-R2-120P1K2 &  ü   ü ü  
500…600V, 50/60 Hz,
Three-Phase
0.75 1 120 360 AK-R2-360P500     ü ü  
1.5 2 120 360 AK-R2-360P500     ü ü  
2.2 3 82 120 AK-R2-120P1K2     ü ü  
4.0 5 82 120 AK-R2-120P1K2     ü ü  
5.5 7.5 51 120 AK-R2-120P1K2     ü ü  
7.5 10 51 120 AK-R2-120P1K2     ü ü  
11 15 51 120 AK-R2-120P1K2 &      ü ü  
♠ Verify resistor Ohms against minimum resistance for drive being used.
▶ Resistors listed are rated 5% duty cycle.
& Requires two resistors wired in parallel.

Spare Parts
Description Cat. No. Used with PowerFlex Drive
4M 4 40 40P 400
Fan Replacement Kits Fan Replacement Kit - Frame A SK-U1-FAN1-A1   ü      
Fan Replacement Kit - Frame B, 1 Fan SK-U1-FAN1-B1   ü ü ü  
Fan Replacement Kit - Frame B, 2 Fans SK-U1-FAN2-B1   ü ü ü  
Fan Replacement Kit - Frame A SK-U1-FFAN1-A1 ü        
Fan Replacement Kit - Frame B SK-U1-FFAN1-B1 ü        
Fan Replacement Kit - Frame C SK-U1-FFAN1-C1 ü        
Fan Replacement Kit - Frame C, 1 Fan SK-U1-FAN1-C1     ü ü ü ⋆ 
Fan Replacement Kit - Frame C, 1 Fan, 15 Hp SK-U1-FAN1-C2     ü ü ü ‡ 
Fan Replacement Kit, NEMA 4X SK-U1-FAN1-B4     ü    
Fan Replacement Kit - Frame D, 2 Fans, B049…B090 & D038…D060 Ratings SK-U1-FAN2-D1         ü
Fan Replacement Kit - Frame E, 2 Fans, B120…B145 & D072…D142 Ratings SK-U1-FAN2-E2         ü
Fan Replacement Kit - Frame F, 2 Fans, IGBT, D170 & D208 Ratings SK-U1-FAN2-F1         ü
Fan Replacement Kit - Frame F, 1 Fan, Rectifier, D170 & D208 Ratings SK-U1-FAN1-F2         ü
Fan Replacement Kit - Frame F, 1 Fan, Choke, D170 & D208 Ratings SK-U1-FAN1-F3         ü
Fan Replacement Kit - Frame G, 1 Fan (Side), D260 & D310 Ratings SK-U1-FAN1-G1         ü
Fan Replacement Kit - Frame G, 4 Fans (Bottom), D260 & D310 Ratings SK-U1-FAN4-G3         ü
Fan Replacement Kit - Frame H, 1 Fan (Upper Side), D370 & D460 Ratings SK-U1-FAN1-H1         ü
Fan Replacement Kit - Frame H, 1 Fan (Middle Side), D370 & D460 Ratings SK-U1-FAN1-H2         ü
Fan Replacement Kit - Frame H, 4 Fans (Bottom), D370 & D460 Ratings SK-U1-FAN4-H3         ü
Covers Encoder Terminal Cover (All Frames) SK-U1-DCVR4-EN       ü  
Frame A Cover with Power Terminal Guard SK-U1-ACVR1-A1   ü      
Frame B Cover with Power Terminal Guard SK-U1-ACVR1-B1   ü      
Frame A Cover SK-U1-FCVR-A1 ü        
Frame B Cover SK-U1-FCVR-B1 ü        
Frame C Cover SK-U1-FCVR-C1 ü        
Frame B Cover with Power Terminal Guard SK-U1-BCVR1-B1     ü    
Frame C Cover with Power Terminal Guard SK-U1-BCVR1-C1     ü    
Frame B Cover, NEMA 4X SK-U1-BCVR1-B4     ü    
Frame B Cover with Power Terminal Guard SK-U1-DCVR3-B1       ü  
Frame C Cover with Power Terminal Guard SK-U1-DCVR3-C1       ü  
Frame C Cover with Power Terminal Guard SK-U1-CCVR1-C1         ü
Frame D Cover SK-U1-CCVR1-D1         ü
Frame E Cover SK-U1-CCVR1-E1         ü
Frame F Cover SK-U1-CCVR1-F1         ü
Frame G Cover SK-U1-CCVR1-G1         ü
Frame H Cover SK-U1-CCVR1-H1         ü
NEMA 4X Replacement Conduit Plugs SK-U1-PLUGS-B4     ü    
⋆ 3…10 HP @ 200…240V AC and 3…10 HP @ 380…480V AC
‡ 15…20 HP @ 380…480V AC

EMC Filters (Required to Meet CE Certification)
Drive Ratings PowerFlex 4M PowerFlex 4 PowerFlex 40/40P PowerFlex 400
Input Voltage kW Hp S Type Filter L Type Filter S Type Filter L Type Filter S Type Filter L Type Filter IP00 (NEMA/UL Type Open)
Cat. No. ⋆  Cat. No. §  Cat. No. ⋆  Cat. No. §  Cat. No. ⋆  Cat. No. §  Cat. No. ⋆ 
100…120V,
50/60 Hz,
Single-Phase
0.2 0.25 22F-RF010-AL 22-RF010-AL
0.4 0.5 22F-RF010-AL 22-RF010-AL 22-RF018-BL ∆ 
0.75 1 22F-RF025-BL 22-RF018-BL 22-RF018-BL ∆ 
1.1 1.5 22F-RF025-BL 22-RF025-CL ♣  22-RF018-BL ∆ 
200…240V,
50/60 Hz,
Single-Phase
0.2 0.25 ‡  22F-RF010-AL ‡  22-RF010-AL
0.4 0.5 ‡  22F-RF010-AL ‡  22-RF010-AL ‡  22-RF018-BL ∆ 
0.75 1 ‡  22F-RF010-AL ‡  22-RF010-AL ‡  22-RF018-BL ∆ 
1.5 2 ‡  22F-RF025-BL ‡  22-RF018-BL ‡  22-RF018-BL ∆ 
2.2 3 ‡  22F-RF025-BL ‡  22-RF025-CL ∆ 
200…240V,
50/60 Hz,
Single-Phase,
NO BRAKE
0.2 0.25 ‡  22-RF010-AL
0.4 0.5 ‡  22-RF010-AL
0.75 1 ‡  22-RF010-AL
1.5 2 ‡  22-RF018-BL
2.2 3 ‡  22-RF025-CL ♣ 
200…240V,
50/60 Hz,
Three-Phase
0.2 0.25 22F-RF9P5-AS 22F-RF9P5-AL 22-RF9P5-AS 22-RF9P5-AL
0.4 0.5 22F-RF9P5-AS 22F-RF9P5-AL 22-RF9P5-AS 22-RF9P5-AL 22-RF021-BS ♦  22-RF021-BL
0.75 1 22F-RF9P5-AS 22F-RF9P5-AL 22-RF9P5-AS 22-RF9P5-AL 22-RF021-BS ♦  22-RF021-BL
1.5 2 22F-RF9P5-AS 22F-RF9P5-AL 22-RF9P5-AS 22-RF9P5-AL 22-RF021-BS ♦  22-RF021-BL
2.2 3 22F-RF021-BS 22F-RF021-BL 22-RF021-BS 22-RF021-BL 22-RF021-BS ♦  22-RF021-BL 22-RF034-CS
3.7 5 22F-RF021-BS 22F-RF021-BL 22-RF021-BS 22-RF021-BL 22-RF021-BS ♦  22-RF021-BL 22-RF034-CS
5.5 7.5 22F-RF039-CS 22F-RF039-CL 22-RF034-CS 22-RF034-CL 22-RF034-CS
7.5 10 22F-RF039-CS 22F-RF039-CL 22-RF034-CS 22-RF034-CL 22-RF034-CS
11 15 22-RFD070
15 20 22-RFD100
18.5 25 22-RFD100
22 30 22-RFD150
30 40 22-RFD150
37 50 22-RFD180
380…480V,
50/60 Hz,
Three-Phase
0.4 0.5 22F-RF6P0-AS 22F-RF6P0-AL 22-RF5P7-AS 22-RF5P7-AL 22-RF012-BS 22-RF012-BL
0.75 1 22F-RF6P0-AS 22F-RF6P0-AL 22-RF5P7-AS 22-RF5P7-AL 22-RF012-BS 22-RF012-BL
1.5 2 22F-RF6P0-AS 22F-RF6P0-AL 22-RF5P7-AS 22-RF5P7-AL 22-RF012-BS 22-RF012-BL
2.2 3 22F-RF012-BS 22F-RF012-BL 22-RF012-BS 22-RF012-BL 22-RF012-BS 22-RF012-BL 22-RF018-CS
3.7 5 22F-RF012-BS 22F-RF012-BL 22-RF012-BS 22-RF012-BL 22-RF012-BS 22-RF012-BL 22-RF018-CS
5.5 7.5 22F-RF026-CS 22F-RF026-CL 22-RF018-CS 22-RF018-CL 22-RF018-CS
7.5 10 22F-RF026-CS 22F-RF026-CL 22-RF018-CS 22-RF018-CL 22-RF018-CS
11 15 22F-RF026-CS 22F-RF026-CL 22-RF026-CS 22-RF026-CL 22-RF026-CS
15 20 22-RFD036
18.5 25 22-RFD050
22 30 22-RFD050
30 40 22-RFD070
37 50 22-RFD100
45 60 22-RFD100
55 75 22-RFD150
75 100 22-RFD180
90 125 22-RFD208
110 150 22-RFD208
132 200 22-RFD323
160 250 22-RFD480
200 300 22-RFD480
250 350 22-RFD480
  

EMC Filters (continued)
Drive Ratings PowerFlex 4M PowerFlex 4 PowerFlex 40/40P PowerFlex 400
Input Voltage kW Hp S Type Filter L Type Filter S Type Filter L Type Filter S Type Filter L Type Filter IP00 (NEMA/UL Type Open)
Cat. No. ⋆  Cat. No. §  Cat. No. ⋆  Cat. No. §  Cat. No. ⋆  Cat. No. §  Cat. No. ⋆ 
500…600V,
50/60 Hz,
Three-Phase
0.75 1 22-RF8P0-BL
1.5 2 22-RF8P0-BL
2.2 3 22-RF8P0-BL
4.0 5 22-RF8P0-BL
5.5 7.5 22-RF015-CL
7.5 10 22-RF015-CL
11 15 22-RF024-CL
⋆ This filter is suitable for use with a cable length of up to 10 meters for Class A and 1 meter for Class B environments.
‡ Drives are available in these ratings with internal “S Type” filters.
§ This filter is suitable for use with a cable length of up to 100 meters for Class A and 5 meters for Class B environments.
♣ The piggyback mounting option cannot be used with Frame B PowerFlex 4 drives and Frame C EMC Line Filters.
∆ PowerFlex 40 Only.
♦ Filter must be Series B or later.

DC Series Bus Inductors
Drive Rating Inductance Cat. No. Used with PowerFlex Drive
Voltage kW Hp Amps mH 4M 4 40 40P 400
200…240V,
50/60 Hz,
Three-Phase
2.2 3 12 1.00 1321-DC12-1         ü
3.7 5 17.5 0.65 1321-DC18-1         ü
5.5 7.5 32 0.85 1321-DC32-1     ü   ü
7.5 10 40 0.75 1321-DC40-2     ü   ü
400…480V,
50/60 Hz,
Three-Phase
2.2 3 6 2 1321-DC9-2         ü
4.0 5 10.5 2.1 1321-DC12-2         ü
5.5 7.5 18 3.75 1321-DC18-4     ü   ü
7.5 10 25 1.28 1321-DC25-4     ü   ü
11 15 32 2.68 1321-DC32-3     ü   ü
15 20 30 2.5 1321-DC40-4         ü
500…600V,
50/60 Hz,
Three-Phase
5.5 7.5 12 2.1 1321-DC12-2_600     ü    
7.5 10 18 3.75 1321-DC18-4     ü    
11 15 25 1.28 1321-DC25-4     ü    
  

Isolation Transformers for PowerFlex 400 - IP32, NEMA/UL Type 3R Standalone, 4…6% Nominal Impedance
             
Click to enlarge - xfmr_sch1   Click to enlarge - xfmr_sch2   Click to enlarge - xfmr_sch3   Click to enlarge - xfmr_sch4
Diagram 1   Diagram 2   Diagram 3
230V Primary, 460V Secondary Only
  Diagram 4
230V Primary, 460V Secondary Only

Rating Wiring Diagram 208V, 60 Hz, Three-Phase Secondary 230V, 60 Hz, Three-Phase Secondary 460V, 60 Hz, Three-Phase Secondary
208V Primary 230V Primary 460V Primary 575V Primary 230V Primary 460V Primary 575V Primary
kW Hp Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No.
2.2 3.0 1/3 1321-3TW005-XX 1321-3TW005-AA 1321-3TW005-BA 1321-3TW005-CA 1321-3TW005-AB 1321-3TW005-BB 1321-3TW005-CB
22 30 2/4 1321-3TW040-AA 1321-3TW040-BA 1321-3TW040-CA 1321-3TW040-AB 1321-3TW040-BB 1321-3TW040-CB
30 40 2/4 1321-3TW051-AA 1321-3TW051-BA 1321-3TW051-CA 1321-3TW051-AB 1321-3TW051-BB 1321-3TW051-CB
37 50 2/4 1321-3TH063-AA 1321-3TH063-BA 1321-3TH063-AB 1321-3TH063-BB
45 60 2/4 1321-3TH075-AB 1321-3TH075-BB
55 75 2/4 1321-3TH093-AB 1321-3TH093-BB
75 100 2/4 1321-3TH118-AB 1321-3TH118-BB
90 125 2/4 1321-3TH145-AB 1321-3TH145-BB
110 150 2/4 1321-3TH175-AB 1321-3TH175-BB
132 200 2/4 1321-3TH220-AB 1321-3TH220-BB
160 250 2/4 1321-3TH275-AB 1321-3TH275-BB
200 300 2/4 1321-3TH330-AB 1321-3TH330-BB
250 350 2/4 1321-3TH440-AB 1321-3TH440-BB
  

Input & Output Line Reactors - 3% Impedance
Drive Ratings IP00 ⋆ 
(NEMA/UL Open Type)
IP11 ⋆ 
(NEMA/UL Type 1)
Used with PowerFlex Drive
Voltage kW Hp Amps Cat. No. Cat. No. 4M 4 40 40P 400
200…240V,
60 Hz,
Three-Phase
0.2 0.25 2.0 1321-3R2-A ü ü      
0.4 0.5 4.0 1321-3R4-B ü ü ü ü  
0.75 1 8.0 1321-3R8-B ü ü ü ü  
1.5 2 8.0 1321-3R8-A ü ü ü ü  
2.2 3 12 1321-3R12-A 1321-3RA12-A ü ü ü ü ü
3.7 5 17.5 1321-3R18-A 1321-3RA18-A ü ü ü ü ü
5.5 7.5 24 1321-3R25-A 1321-3RA25-A ü   ü ü ü
7.5 10 33 1321-3R35-A 1321-3RA35-A ü   ü ü ü
11 15 49 1321-3R45-A 1321-3RA45-A         ü
15 20 65 1321-3R55-A 1321-3RA55-A         ü
18.5 25 75 1321-3R80-A 1321-3RA80-A         ü
22 30 90 1321-3R80-A 1321-3RA80-A         ü
30 40 120 1321-3R100-A 1321-3RA100-A         ü
37 50 145 1321-3R130-A 1321-3RA130-A         ü
380…480V,
60 Hz,
Three-Phase
0.4 0.5 2.0 1321-3R2-B ü ü ü ü  
0.75 1 4.0 1321-3R4-C ü ü ü ü  
1.5 2 4.0 1321-3R4-B ü ü ü ü  
2.2 3 6.0 1321-3R8-C 1321-3RA8-C ü ü ü ü ü
4.0 5 10.5 1321-3R8-B 1321-3RA8-B ü ü ü ü ü
5.5 7.5 12 1321-3R12-B 1321-3RA12-B ü   ü ü ü
7.5 10 17 1321-3R18-B 1321-3RA18-B ü   ü ü ü
11 15 22 1321-3R25-B 1321-3RA25-B ü   ü ü ü
15 20 30 1321-3R35-B 1321-3RA35-B         ü
18.5 25 38 1321-3R35-B 1321-3RA35-B         ü
22 30 45.5 1321-3R45-B 1321-3RA45-B         ü
30 40 60 1321-3R55-B 1321-3RA55-B         ü
37 50 72 1321-3R80-B 1321-3RA80-B         ü
45 60 88 1321-3R80-B 1321-3RA80-B         ü
55 75 105 1321-3R100-B 1321-3RA100-B         ü
75 100 142 1321-3R130-B 1321-3RA130-B         ü
90 125 170 1321-3R160-B 1321-3RA160-B         ü
110 150 208 1321-3R200-B 1321-3RA200-B         ü
500…600V,
60 Hz,
Three-Phase
0.75 1 2.0 1321-3R2-B     ü ü  
1.5 2 4.0 1321-3R4-C     ü ü  
2.2 3 4.0 1321-3R4-B     ü ü  
4.0 5 8.0 1321-3R8-C     ü ü  
5.5 7.5 12 1321-3R12-B     ü ü  
7.5 10 12 1321-3R12-B     ü ü  
11 15 18 1321-3R18-B     ü ü  
⋆ Catalog numbers listed are for 3% impedance. 5% impedance reactor types are also available. Refer to publication 1321-TD001….