Allen-Bradley Home

Protection Systems

General Resources



XM-123 Aeroderivative Module

Introduction Communication Inputs Tachometer Outputs Indicators
Single Conditioning Measured Parameters Data Buffers Alarms Relays Non-Volatile Configuration
Power Approvals Environmental Physical Ordering Instructions

Inputs


2 Channels of:

  • Accelerometer signals
  • Voltage signals from any dynamic measurement device, such as a velocity or pressure transducer


Transducer Power:

  • Constant current (4.5mA ±20% from +24V dc)¬ 
  • None (voltage input)


¬ Tachometer may be powered, constant voltage, or configured as voltage input.


Voltage Range:

Selectable in software as 0 to ±20V (min) 40Vmax. peak-to-peak


Sensitivity:

User configurable in software


Input Impedance:

>100k