Allen-Bradley Home

Protection Systems

General Resources



XM-123 Aeroderivative Module

Introduction Communication Inputs Tachometer Outputs Indicators
Single Conditioning Measured Parameters Data Buffers Alarms Relays Non-Volatile Configuration
Power Approvals Environmental Physical Ordering Instructions

Single Conditioning


Sampling Modes:

Band Pass Mode

  • Minimum Freq (25 to 1000 Hz)
  • Maximum Freq (100 to 5500 Hz)


Tracking Filter Mode

  • Tracked Speed Multiple: 0.1 to 20.0 times the measured (tachometer) RPM
  • Constant Bandwidth (Hz) or
  • Constant Q


Frequency Range:

1 Hz to 20 kHz


Resolution:

  • A/D Conversion: 24 bits
  • Dynamic Range: <80dBfs (0.01% fs), -90dBfs (typical)


Amplitude Range:

Dependent on sensitivity


Integration:

One level provided in hardware


Low Pass Filters:

Independently configured per channel

  • Optional Overall measurement LP filter: 200 Hz - 20 kHz; Roll Off: -24 dB per octave


High Pass Filters:

Independently configured per channel

  • Integration OFF: 1, 5, 10, 40, 1000 Hz, Roll Off: -30 dB per octave for the 1 Hz HPF, otherwise -24 dB per octave
  • Integration ON: 5, 10, 40, 1000 Hz, Roll Off: -30 dB per octave for the 5 Hz HPF, otherwise -24 dB per octave


Units:

  • g
        
  • mm/s
  • um
  • psi
  • ips
  • mils
  • volt
  • Pa