360 Process Module The XM®series from Rockwell Automation is the worlds first machine monitoring and protection system designed as a distributed network of modules deployed on an open standard industrial bus. The XM-360 Process Module is an intelligent 6-channel general-purpose process monitor. It is a complete process monitoring system in a compact, easily installed, easily maintained package. The module can be configured to measure a DC voltage or a loop current input on each channel and will report both the data value, in engineering units, and the rate of change for each channel. For applications where it is not possible to integrate XM® data directly via DeviceNet the XM-360 provides a standard 4-20mA output for each channel. And for applications requiring relays the XM-360 supports linking of up to two XM-441 Expansion Relay modules thereby providing a total capacity of up to 8 relays. The XM-360 can operate stand alone, with no interface to higher-level control systems or interactive user interfaces. It can also be deployed on a standard or dedicated DeviceNet™ network where it can provide real-time data and status information to other XM® modules, PLCs, DCS and Condition Monitoring Systems. Configuration can be performed remotely via the DeviceNet™ network, or locally by a PC connected to the integral serial interface. For local configuration, a Serial Configuration Utility is packaged with every XM® measurement and relay module sold. Specifications
Communications DeviceNet
Side Connector: All XM measurement and relay modules include side connectors that allow interconnecting adjacent modules thereby simplifying the external wiring requirements. The Interconnect provides primary power, DeviceNet communication and the circuits necessary to support expansion modules such as the XM-441 Expansion Relay module. Serial ¬
Isolation: Up to 250 volts of isolation for each input Sensitivity: User configurable in software Input Range: User configurable per channel as:
Input Impedance:
Outputs 4-20mA Outputs:
Isolation
Indicators 8 LEDs:
Signal Conditioning Low Pass Filter: User configurable for the measurement and rate of change value from each channel Resolution: 0.025% of input range
Measured Parameters Rate of Change:
Data Buffer Trend Buffer Stores a set of records containing measured parameters in response to a trigger event.
Alarms Number: 12 alarm and danger pairs Operators:
Hysteresis: User defined Relays Number:
Latching:
Time Delay: 0 to 25.5 seconds in 100msec increments Voting Logic: Single or paired And or Or logic applied to any alarms Reset:
Activation On:
Non-Volatile Configuration A copy of the module configuration is retained in nonvolatile memory from where it is read upon power up.¬ ¬ The configuration stored in Non-Volatile memory can only be deleted by module-reset command sent via the serial interface, using the Serial Configuration Utility, or via DeviceNet from any compliant software application. Power
Environmental
Conformal Coating All printed circuit boards are conformal coated:
Physical
Ordering Informaton
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||