361 & 362 Temperature Modules The Entek XM® series from Rockwell Automation is the worlds first machine monitoring and protection system designed as a distributed network of modules deployed on an open standard industrial bus. The XM-361 Universal Temperature Module and the XM-362 Isolated TC Temperature Module are intelligent 6-channel temperature monitors. Each module is a complete temperature monitoring system in a compact, easily installed, easily maintained package. Each channel of the XM-361 module can be configured to measure either an RTD or an isolated thermocouple while the XM-362 is designed specifically for thermocouple measurements - isolated or grounded. For applications where it is not possible to integrate XM® data directly via DeviceNet the modules provide standard 4-20mA outputs for each channel. And for applications requiring integral relays the modules support linking of up to two XM-441 Expansion Relay modules thereby providing a total capacity of up to 8 relays. The XM-361 and XM-362 Temperature Modules can operate stand alone, with no interface to higher-level control systems or interactive user interfaces. They can also be deployed on a standard or dedicated DeviceNet network where they can provide real-time data and status information to other XM® modules, PLCs, DCS and Condition Monitoring Systems. Configuration can be performed remotely via the DeviceNet network, or locally by a PC connected to the integral serial interface. For local configuration, a Serial Configuration Utility is packaged with every Entek XM® measurement and relay module sold. Specifications
Communications DeviceNet:
Side Connector: All XM measurement and relay modules include side connectors that allow interconnecting adjacent modules thereby simplifying the external wiring requirements. The Interconnect provides primary power, DeviceNet communication and the circuits necessary to support expansion modules such as the XM-441 Expansion Relay module. Serial:¬
Inputs Supported Sensors
Outputs 4-20mA Outputs:
Isolation:
Indicators 8 LEDs:
Signal Conditioning Accuracy:
Resolution: 0.025% of range Low Pass Filter: User configurable for the measurement and rate value from each channel Sampling Rate: 200 Hz Measured Units:
Data Buffer Trend Buffer: Stores a set of records containing measured parameters in response to a trigger event.
Alarms Number: 12 alarm and danger pairs Operators:
Hysteresis: User defined Relays Number:
Latching:
Time Delay: 0 to 25.5 seconds in 100msec increments Voting Logic: Single or paired And or Or logic applied to any alarms Reset:
Activation On:
Non-Volatile Configuration A copy of the module configuration is retained in nonvolatile memory from where it is read upon power up.¬ ¬ The configuration stored in Non-Volatile memory can only be deleted by module-reset command sent via the serial interface, using the Serial Configuration Utility, or via DeviceNet from any compliant software application. Power
Environmental
Conformal Coating All printed circuit boards are conformal coated:
Physical
Ordering Informaton
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||