Programmable Automation Controllers
CompactLogix System
Controller
CompactLogix controllers integrate easily with other members of the Logix family of controllers and are programmed using RSLogix 5000, just like other members of the Logix controller family. So, if you are also running ControlLogix, you can easily duplicate and scale existing programs to run on CompactLogix.
CompactLogix networked controllers integrate an EtherNet/IP or ControlNet connection and are designed to meet the challenged of demanding applications. The CompactLogix EtherNet/IP family of controllers includes the 1769-L23E, 1769-L35E and the 1769-L32E. The CompactLogix ControlNet family of controllers includes the 1769-L35CR and the 1769-L32C.
Standalone Controllers
CompactLogix is also ideal for systems that require standalone control. For cost-effective sequential and process machine control applications, consider the 1769-L23 family of packaged controllers or 1769-L31 controllers. For low-axis count motion control applications, consider the 1768-L43 (up to 4 axes) or the 1768-L45 (up to 8 axes).
CompactLogix controllers offer:
- High-performance CPU
- Designed to meet demanding applications
- Significant performance and capacity
- Extensive I/O capacity, throughput, and functionality
- Cost-effective, rackless I/O
- Control distributed I/O via EtherNet/IP or ControlNet
- Seamless bridging with data control and collection over the same network
- Front-accessible, removable CompactFlash
- Integrated motion
- Sequential, process and motion in a single programming environment
- SERCOS drives interface
| 1769-L23- QBFC1B |
1769-L23E- QB1B |
1769-L23E- QBFC1B |
1769-L31 (5331) |
1769-L32E (5332) |
1769-L35E (5335) |
1769-L32C | 1769-L35CR (5335) |
1768-L43 | 1768-L45 |
|---|---|---|---|---|---|---|---|---|---|
| User Memory | |||||||||
| 512 KB | 512 KB | 512 KB | 512 KB | 750 KB | 1.5 MB | 750 KB | 1.5 MB | 2 MB | 3 MB |
| Nonvolatile Memory | |||||||||
| None | None | None |
|
|
|
|
|
|
|
| Maximum I/O Modules | |||||||||
| 2 | 2 | 2 | 16 | 16 | 30 | 16 | 30 | 16 | 30 |
| Maximum Banks of I/O Modules | |||||||||
| Additional modules are connected directly to the packaged controller. There are no additional banks of local I/O. | 3 | 3 | 3 | 3 | 3 | 3 | 3 | ||
| Communication Ports | |||||||||
|
|
|
|
|
|
|
|
|
|
| Network Connectivity | |||||||||
|
|
|
|
|
|
|
|
|
|
| Program Tasks | |||||||||
|
|
|
|
|
|
|
|
|
|
| Minimum I/O Update Period | |||||||||
| 2.0 ms | 1.0 ms | 1.5 ms | 1.0 ms | 1.0 ms | 1.0 ms | 1.0 ms | 1.0 ms | 1.0 ms | 1.0 ms |
| Backplane Current | |||||||||
|
|
|
|
|
|
|
|
|
|