Drives Service & Support > 1305 > Drive Specifications

Click for Dimensions



1. Motor Full Load Amps (FLA) should not exceed the drive output current rating.
2. If the [PWM Frequency] is set above 4kHz, the output current must be derated per the chart on page 5- 20. When operating the drive in an ambient temperature at or near the maximum operating temperature (50 ° C), the following derating guidelines are recommended to guard against overheating depending on application and operating conditions.
3. Output current value listed for 200V input voltage. At 230V input voltage, output current is 9.6A for 3 phase and 6.8A for single phase.
4. Output current value listed for 380V input voltage. At 415V input voltage, output current is 5.3A. At 460V input voltage, output current is 4.8A.
5. Output current value listed for 380V input voltage. At 415V input voltage, output current is 8.4A. At 460V input voltage, output current is 7.6A.
* For derating guidelines at ambient temperatures between 40 ° C and 50 ° C, consult Allen- Bradley.


Control Inputs

Programmable Output 1 Form A Relay Contact: Resistive Rating 115V AC/ 30V DC, 5A; Inductive Rating 115V AC/ 30V DC, 2A
Programmable Output 2 Open Collector (Sink): 24V DC, +/- 20%, 50 mA maximum (User supplied source voltage)
Analog Output (0 to 10V DC) Load lmpedance >= 4,000 Ohms, 8 bit resolution
PWM AIgorithm Sine Weighted PWM Output
Switching Device 3- Phase Output IGBT Intelligent Power Module
V/ Hz Ratio Programmable
Carrier Frequency Adjustable in 100Hz Increments from 2 kHz to 8 kHz. Output Current Derating applies above 4 kHz.
DC Boost

Adjustable single point or full custom - Start and Run boost available



CONTROL FEATURES

Current Limiting Trip Free Operation, Co- ordinated for Drive and Motor Protection Programmable from 20% to 150% of Drive Rated Current
Overload 200%, Fixed by hardware, based on drive rating 150% for 60 seconds
Motor Protection (1) Electronic Overload Protection. Adjustable from 20% to 115% (Motor FLA)
Overload Pattern #0 Flat response over speed range (no current derating)
Overload Pattern #1 Current derating below 25% of Base Speed
Overload Pattern #2 Current derating below 50% of Base Speed
Accel/ Decel Time(s) 0.1 to 3600 Seconds, independently set (2 Accel, 2 Decel)
Preset Speeds 0 to 400 Hz, 7 selections, independently set
Jog Input 0 to 400 Hz
Stopping Modes 4 modes programmable
Ramp to stop 0.1 to 3600 seconds
Coast Stops all PWM Output
DC Brake to stop Applies DC Voltage to the Motor for 0 to 150 seconds. Has nothing to do with dynamic braking or external brake operation.
S- Curve Ramps to stop with S- Curve profile
Protective Features
Excessive Temperature Embedded temperature sensor trips if factory preset level is exceeded (2)
Over/ Under Voltage DC Bus voltage is monitored
Power Ride Through Minimum ride through 15mS under nominal conditions
Control Ride Through Minimum ride through is 0.5 Seconds - typical value 2 seconds
Ground Short Any output short to ground, detected prior to start
Line Voltage Transients Inherent MOV (varistor) protection
Output Short Circuit Inherent short circuit protection provided within IPM

1. See Page 5- 12 for NEC and UL information.
2. Conditions such ambient temperature, overload, duty cycle, etc. can affect tripping time.

PROGRAMMING/ COMMUNICATIONS

Adapters The maximum current draw of all adapters connected to the drive should not exceed 250 mA
Hand Held Programming Optional Human Interface Module (HIM can be removed from the Drive)
Type of Annunciation Parameters displayed in textual form, organized in Iogical groupings
Type of Display 16 character, 2 line LCD supertwist with backlight
Language Capability Multiple Languages available
Local Controls 3 versions available ( Digital Pot., Analog Pot. and Blank)
Communication Adapters Optional adapters provide Remote I/ 0, or RS232/ RS422/ RS485/ DF1/ DH485, or DeviceNet? capability.
MONITORING
Output Frequency (Hz) Displayed over the entire range of operation with direction indication
Output Voltage (V) Selectable as a displayed parameter
Output Current (A) Selectable as a displayed parameter in % or actual value
Output Power (kW) Selectable as a displayed parameter in % or actual value
DC Bus Voltage (V) Selectable as a displayed parameter
Frequency Command (Hz) Selectable as a displayed parameter
Process Parameter Any drive variable can be scaled and definable text can be added up to 8 characters
Drive Temperature `C Selectable as a displayed parameter
Last Fault The previous 4 faults can be displayed for troubleshooting