| Environmental |
| Ambient operating temperature |
IP00, Open: 0 - 50°C (32 - 122°F)
IP20, NEMA Type 1 Enclosed: 0 - 40°C (32 - 104°F)
IP65, NEMA Type 4 Enclosed: 0 - 40°C (32 - 104°F) |
| Storage temperature (all constructions) |
-40 - 70°C (-40 - 158°F) |
| Relative humidity |
5 - 95% non-condensing |
| Altitude |
1000m (3300ft) without derating |
| Shock |
15g peak for 11ms duration (+1.0 ms) |
| Vibration |
0.152mm (0.006 inches) displacement. 1g peak |
| Electrical |
| Input voltage rating (See the derating curves for voltages above nominal) |
200-240V AC, standalone, 3 phase, +10%, -15% nominal
380-480V AC, standalone, 3 phase, +10%, -15% nominal
500-600V AC, standalone, 3 phase, +10%, -15% nominal
513-621V DC, common bus, +10%, -15% nominal
776V DC, common bus, +10%, -15% nominal |
| Input power rating |
2-134 KVA (230V)
2-437 KVA (380V)
2-555 KVA (460V)
2/3 - 578/695 KVA (500/600V) |
| Input frequency |
50/60 Hz (±3 Hz) |
| Standard output voltage |
Three voltage ranges are available. Each voltage range is line dependent and can power a motor between the following voltages:
200 - 240V AC (line dependent)
380 - 480V AC (line dependent)
500 - 600V AC (line dependent)
If the voltage required for your application is not shown, contact Allen-Bradley for specific information.
Note: Due to internal voltage drops in the power structure and voltage margins required for regulation, the drive is unable to produce full output voltage at base speed. If full horsepower is required at or above base speed, an increase in current is required to produce rated horsepower. This effect will occur in all drives, but is usually only significant in F, G, and, especially, H frame drives since the voltage drop is proportional to source inductance and load current. |
| Output power |
2 - 116 KVA (230V)
2 - 190 KVA (380V)
2 - 208 KVA (415V)
2 - 537 KVA (460V)
2 - 671 KVA (575V)
Note: For information on factors that could effect the power output of the drive, please refer to the enclosure and derating guidelines. |
| Output current |
2.5 - 983A |
| Output horsepower (continuous) |
7.5 - 800 hp |
| Overload capability |
Continuous - 100% fundamental current
1 minute - 150% |
| Output frequency range |
0 - 250 Hz |
| Output waveform |
Sinusoidal (PWM) |
| Maximum short circuit current rating |
200,000A rms symmetrical, 600 volts (when used with specified AC input line fuses as detailed in Chapters 3 and 4) |
| Ride through |
2 seconds |
| Efficiency |
97% typical |
| Performance |
| Speed regulation with an encoder |
To 0.001% of rated motor speed over a 100:1 speed range
To 0.02 % of rated motor speed over a 1000:1 speed range |
| Speed regulation without an encoder |
±0.5% of rated motor speed over a 120:1 speed range |
| Torque regulation |
To ±5% of rated motor torque, encoderless; ±2% with an encoder. |
| Power loss ridethrough capability |
2 seconds |
| Flying start |
Can start into a spinning motor |
| Inverter overload capability |
Constant torque: 150% of rated drive output for 1 minute. |
| Motor overload capability |
Adjustable to up to 400% of motor rating for 1 minute. |
| Programmable accel/decel rates |
From 0 to 6553 seconds |
| Current limit |
Programmable to 400% of rated motor current, not to exceed 150% of the drive output limit. |
| Control |
| Force Technologies: Field-oriented control, current-regulated, sine code PWM with programmable carrier frequency |
 |
| Output voltage range |
0 to rated voltage |
| Output frequency range |
0 to 250 Hz |
| Encoder |
Incremental, dual channel; isolated with differential transmitter, 100 kHz maximum, quadrature: 90°±27° @ 25°C. Supply power: 12 volts, 500mA Input: 5 volts (2.5 volts minimum, 10mA minimum) or 12 volts (9.5 volts minimum, 10mA minimum) |
| Accel/decel |
Independently programmable acceleration and deceleration times. Program from 0 to 6553 seconds in 0.1 second increments. |
| Current limit |
±400% rated motor current up to inverter rating |
| Inverse time overload capability |
Class 20 protection with speed-sensitive response adjustable from 0-200% of rated output current in three speed ranges -- 2:1, 4:1, and 10:1. UL certified-- Meets NEC article 430. |
| Input/Output |
| 0 to ±10V DC input |
Input impedance of 20K Ohms |
| 4-20 mA input |
Input impedance of 130 Ohms |
| Pulse input |
Differential, input 5 or 12V, maximum frequency of 100 kHz, 10 mA minimum |
| 0 to ±10V DC output |
Output impedance of 100 Ohms, 10 mA maximum |
| 4-20 mA output |
Output impedance of 273 Ohms; can drive up to 3 inputs |
| DC power supply |
±10V DC, 50 mA per voltage |
| Fault contact |
Resistive rating = 115 VAC/30VDC, 5.0A
Inductive rating = 115 VAC/30VDC 2.0A |
| Alarm contact |
Resistive rating = 115VAC/30VDC, 5.0A
Inductive rating = 115VAC/30VDC, 2.0A |