Drives Service & Support
Click for Dimensions or Input/Output Ratings
| Standard Drive Features |
The Bulletin 1336 FORCE Field Oriented AC Drive is a microprocessor controlled Digital AC Drive with the following features:
- 1 to 650 HP at 0 - 250 HZ constant torque
- Four Quadrant operation available
- High Performance Digital Velocity Loop
- Microprocessor controlled, field oriented current loop
- Simplified programming through the use of a Parameter Table that features data entries in engineering units with English descriptions
- Nonvolatile Parameter Storage
- Extensive diagnostics, including both logic board and power structure tests
- Time stamped nonvolatile Fault/Warning Queue
- Real Time Clock
- Reference Time Stamp
- Run Time Accumulator
- Enclosed Construction
- Multiple Communication Interfaces
- Complete Encoder Interface
- Drive to Drive Link
- SCANport Peripheral Interface
|
| Performance Specifications |
- Speed Regulation to 0.001% of top speed.
- Torque Regulation to ± 5% of rated motor torque.
- Power Loss Ride-Thru capability of two seconds.
- Flying Start: Capability of starting into a spinning motor.
- Torque Linearity 1%
- Overload Capability: 150% for 1 minute, 200% of motor rating for 10 seconds, up to inverter limit.
- Programmable Accel/Decel rates from 0 to 6553 seconds
- Current limit programmable from 200% of rated output current.
|
| Control Specifications |
Indirect Self-Organized, Field-Oriented Control, Current-regulated, sine coded PWM with programmable carrier frequency. |
| HP |
Drive Rating |
Carrier Frequency |
| 1-3 |
4 |
1-12 kHz |
| 7.5-30 |
4 |
1-12 kHz |
| 40-60 |
4 |
1-12 kHz |
| 75-125 |
2 |
1-6 kHz |
| 150-250 |
2 |
1-6 kHz |
| 300-500 |
2 |
1-4 kHz |
| 600-650 |
2 |
1-4 kHz |
| 700-800 |
1 |
1-4 kHz |
| Refer to Derating Guidelines in the Appendix of this manual |
- Output Voltage Range - 0 to rated voltage
- Output Frequency Range - 0 to 250 Hz.
- Speed Regulation with Encoder Feedback - 0.001% of Top Speed over a 100.1 Speed Range.
- Encoderless Speed Regulation - 1% of Top Speed over a 40:1 Speed Range.
- Accel/Decel - Independently programmable accel and decel times. Program from 0 to 6553 seconds in 0.1 second increments.
- Current Limit - Independent Motoring and Regenerative Limit
- Inverse Time Overload Capability - Class 20 protection with speed-sensitive response. Adjustable from 0-200% of rated output current in 3 speed ranges - 2:1, 4:1 & 10:1. UL Certified - Meets NEC Article 430.
|
| Options |
- Standard Adapter Board which provides: - 2 Analog Inputs +/-10V - 2 Analog Outputs +/- 10V - One 4-20mA input - One 4-20mA output - 5 or 12 vdc pulse input - +/- 10V reference voltages - At Speed, Run, Fault and Alarm contacts
- PLC Communication Adapter Board which provides: - 4 Analog Inputs +/-10V - 4 Analog Outputs +/- 10V - +/- 10V Reference voltages - RIO/DH? + Communications (2 channels selectable) - Function Blocks
- DriveTools?; PC Windows? based programming software compatible with the 1336 FORCE Drive and also other Allen-Bradley 1336 and 1395 products.
- Dynamic Braking
- AC Motor Contactor
|
| Protective Features |
- Programmable Motor Overload Protection (I 2 T) investigated by UL to comply with NEC Article 430.
- Programmable Inverter Overload Protection (IT)
- Overspeed Detection, even when operating as a torque follower.
- Programmable Stall Detection
- Peak output current monitoring to protect against excessive current at the output due to a phase to ground or phase to phase short.
- Ground fault monitoring
- DC Bus Voltage monitoring to protect against under/over voltage conditions.
- Power Structure Heatsink Temperature Monitoring
|
| Environmental Specifications |
The following environmental guidelines apply to both the 1336 FORCE Drive and all devices and accessories connected to the Drive.
Ambient Operating Temperature:
- IP00, Open: 0 to 50 degrees C (32 to 122 degrees F).
- IP20, NEMA Type 1 Enclosed: 0 to 40 degrees C (32 to 104 degrees F).
- IP65, NEMA Type 4 Enclosed: 0 to 40 degrees C (32 to 104 degrees F).
- Storage Temperature (all constructions): -40 to 70 degrees C (-40 to 158 degrees F).
Relative Humidity: 5 - 95% non-condensing
Altitude: 1000m (3300 ft) without derating.
Shock: 15g peak for 11ms duration (+ 1.0 ms).
Vibration: 0.006 inches (0.152 mm) displacement. 1G peak. |
| Electrical Specifications |
Input Voltage Rating:
- 200 - 240VAC, Standalone, 3 Phase, +10%, -15% nominal
- 380 - 480VAC, Standalone, 3 Phase, +10%, -15% nominal
- 500 - 600VAC Standalone, 3 Phase, +10%, -15% nominal
- 513 - 621 VDC, Common Bus, +10%, -15% nominal
- 776 VDC, Common Bus, +10%, -15% nominal
Input Power Rating:
- 2 - 134 KVA (230V)
- 2 - 437 KVA (380V)
- 2 - 555 KVA (460V)
- 2/3 - 578/694 KVA (500/600V)
Input Frequency: 50/60HZ (±3HZ)
Standard Output Voltage*: Four frame sizes are available. Each frame size is line dependent and can power a motor between the following voltages:
- 200 - 240 Vac (line dependent)
- 380 - 480 Vac (line dependent)
- 500 - 600 Vac (line dependent)
*If voltage required for your application is not shown, contact Allen-Bradley for specific application.
Output Current: 2.5 - 673A
Output Power:
- 2 - 116 KVA (230V)
- 2 - 190 KVA (380V)
- 2 - 208 KVA (415V)
- 2 - 537 KVA (460V)
- 2 - 671 KVA (575V)
Note: For information on factors that could effect the power output of the drive please refer to the Enclosure and Derating Guidelines in the Appendix of this manual.
Output Horsepower (Continuous): 7.5 - 650HP
Overload Capability: Continuous - 100% Fundamental current 1 minute - 150%
Output Frequency Range: 0 - 250 HZ
Output Waveform: Sinusoidal (PWM)
Max. Short Circuit Current Rating : 200,000A rms symmetrical, 600 volts (when used with specified AC input line fuses as detailed in Table 2.A).
Ride Through: 2 seconds minimum
Efficiency: 97.5% at rated amps, nominal line volts |
| Feedback Devices |
Encoder: Incremental, dual channel; 12 volts, 500mA, Supply, 5/12 Volt 10ma Min Inputs, isolated with differential transmitter, 102.5 KHz max. Quadrature: 90° ±27° @ 25°C, Duty Cycle: 50% + 10%.
Speed Regulation with Encoder Feedback: 0.001% of Top Speed over a 100:1 Speed Range. Encoderless Speed Regulation: 0.5% of Top Speed over a 40:1 Speed Range. |