Application Logic for Fibers Applications • Programmable inertia ride-through after line-loss detection
• Built-in traverse function
• Synchronized speed change functionality
• Synchronous motor “sync loss” detection and recovery
• Phase-locked loop function allows speed command to lock onto a pulse train input
Operator Interface • Hand-held HIM available for programming and diagnostics
• Multi-language support
Drive Protection • Overvoltage and Programmable Undervoltage
• Hardware Current Limit and Heatsink Overtemperature
• Output Phase-to-Phase and Phase-to-Ground Short Circuit
• AC line Input Transient Suppression
Drive Adjustments Accel/Decel 0-600 Seconds in 0.01 Second Increments, Linear or S-Curve
Line Loss Recovery 4 Programmable Options
Stop Mode Coast/Ramp/Brake/Ramp to Hold
Motor Control Sensorless Vector; V/Hz
Speed Regulation Mode Open Loop, Process PI
Traverse Traverse Inc., Traverse Dec., Max. Traverse, P Jump
Synchronous Speed Change Sync Time
Synchronous Motor “Sync Loss” Sync Loss Gain, Sync Loss Time, Sync Loss Comp
Ambient Operating Temperatures IP 20; NEMA Open Type
0° to 50° C
Input Specifications Three-Phase Voltage +10% of maximum, -50% of nominal (at reduced output power)
Frequency 47 to 63 Hz
Power Loss Ride Through 30ms at full load
Control Ride Through 2.5 seconds minimum (not running)
Output Specifications and Dimensions Voltage 0 to rated voltage
Frequency Range 0 to 400 Hz
Frequency Accuracy ± 0.01% of set output frequency from digital setpoint
Speed Regulation 0.01% (synchronous motor)
0.5% with slip compensation (induction motor)
Dynamic Response 12 Radians
Time at Peak Current 20 Seconds Maximum every 10 Minutes
Current Varies by catalog number – see table below


Note: Current Ratings in 50°C ambient with 2kHz carrier