| Input Voltage |
1 /4-1 HP 115V AC ±10% Single Phase
1 /2-2 HP 230V AC ±10% Single Phase |
| Input Frequency |
50/60 Hz ±2 Hz |
| Construction |
Open Chassis NEMA Type 4/12 (For Indoor Use) |
| Output Current |
10 Amps Maximum |
| Output Horsepower |
1 /4-1 HP 90V DC
1 /2-2 HP 180V DC |
| Service Factor |
1.0 |
| Certification |
UL LISTED/CSA APPROVED |
| Speed Regulation |
Voltage Feedback 2-5% (95% Load Change)
Tachometer Feedback 1% (95% Load Change) |
| Speed Range |
20:1 with Armature Voltage Feedback
30:1 with Tachometer Feedback (except 1365-DAF) |
| Ambient Operating Temperature |
Open Chassis 0-55°C (32-131°F)
NEMA Type 4/12 0-40°C (32-104°F) |
| Relative Humidity |
5-95% Non-Condensing |
| Altitude |
3,300 feet (1,000 meters) |
| Maximum Speed |
Adjustable from 50-100% |
| Minimum Speed |
Adjustable from 5-50% |
| Current Limit |
Adjustable to 150% |
| IR Compensation |
5-10% of Rated Armature Voltage |
| Efficiency |
97% Controller Efficiency at Rated Speed and Load
78% Combined Controller/Motor Efficiency at Rated Speed and Load |
| Protective Functions |
Built-in Surge Suppressors to Help Protect Semiconductors Against High Line Transients
Relay in Control Circuit to Prevent Automatic Restarting After Power Loss |
| Accel/Decel |
Adjustable: 0.5-30 Sec. Process Control & Torque Drives: 0.3-3.5 Sec. or 3.5-40 Sec. |