Drives Service & Support > 1395 > Specifications

Electrical
Input Voltages 150 – 460VAC +/– 10%, 3 phase
Input Power 1.5 kVA to 660 kVA
Input Frequency 50/60Hz +/– 3 Hz.
Max Rate of Change 0.5 Hz/Sec.
Output Voltage 240VDC (230VAC Input)
400VDC (380 – 415 AC Input)
500VDC (460VAC Input)
Output Horsepower (Continuous) 1 to 300 HP, 240VDC
1.5 to 500 HP, 400VDC
2 to 600 HP, 500VDC
Output Current 3.6 to 980A
Field Voltage 120 – 150VDC, 230VAC
200 – 250VDC, 380VAC
220 – 270VDC, 415VAC
240 – 300VDC, 460VAC
Field Voltage Source is selectable between internal or external supply.
Field Current 1 – 30HP, 230V; 2 – 60HP, 460V Drive:
150mA – 10 Amperes Continuous
40 – 100HP, 230V; 75 – 200HP, 460V
Drive: 650mA – 20 Amperes (continuous)
125 – 300HP, 230V; 250 – 600HP, 460V
Drive: 650mA – 40 Amperes (continuous)
Field Control A 6:1 speed range with an encoder or DC tach feedback
Field Economy Programmable enable, time delay, power on standby
Armature Firing Phase sequence insensitive, Regenerative/Non–regenerative
Output Waveform 6 pulse, full wave, NEMA Code C
Controller Current Output 150% for one minute, 200% for 10 seconds, 260% for 5 seconds
Armature Control Tapered current limit,di/dt limit, Instantaneous overcurrent, Programmable motor overload
Speed Regulation
Encoder 0.01% of set speed (over a 10:1 speed range); 0.001% of top speed (over a 100:1 speed range).
DC Tachometer 0.5% of top speed with 5PY tachometer; 0.1% of top speed with BC42 tachometer.
Armature Voltage 2% of top speed
Feedback Devices
DC Tachometer 5 PY, BC42 or equal
Encoder Incremental, dual channel; 12 volts, 500mA, isolated with differential transmitter, 102.5 kHz max. Quadrature : 90°± 27° @ 25°C, Duty Cycle: 50% ± 10% Source/Sink capable, A-B 845H or equal
External Inputs
Enable/Contingency Coast Stop 24VDC/115VAC, hard-wired to DC contactor
System Reset 24VDC/115VAC, Isolated
Motor Thermostat 24VDC/115VAC, Isolated
Communication Port RS-422 for programming terminal
External Outputs
Drive Ready/Faulted N.O. relay contact, open when drive faulted or de-energized, closed when ready. Contact rating - 1 ADC @ 24 VDC or 0.5A @ 120VAC
Environmental
Ambient Operating Temperature 0° to 55°C (32° - 130° F)
Relative Humidity 5% to 95%, non-condensing
Altitude 3,300 feet (1,000 meters)
Standard Features
Accel/Decel 0.1 to 6554 seconds, independently programmable.
Preset Speeds 5 adjustments, programmable
Jog Speeds 2 adjustments, programmable
"S" Ramp Programmable
Motor Operated Pot (MOP) 10 adjustments, programmable
Options
Discrete Adapter Board
Digital Inputs (4) 24VDC or 120VAC, 10 mA. NOTE: A separate board and part number is used for each voltage rating.
Digital Outputs (2) Dry relay contacts rated at 0.6 amps at 125VAC or 2.0 amps at 30VDC.
Analog Inputs (4) 0 to +/- 10 VDC, differential input impedance - 20K ohms.
Analog Outputs (4) -10 to + 10VDC, 1mA minimum output impedance - 200 ohms.
Power Supply (For external use) +10VDC, 4mA maximum, -10VDC, 4mA maximum.
Digital Reference Board
Digital Reference Input (1) Current source and sink input for high common mode noise immunity. Nominal 5VDC or 12VDC interface (internal hardware configurable), + 10mA nominal current source/sink requirements.
Digital Inputs (10) 24VDC Nominal; 18VDC minimum, 28VDC maximum; 10 ma nominal.
Discrete Outputs (5) 24VDC nominal; Current sourcing type driver; Diode clamped for inductive load; 18VDC minimum, 28VDC maximum; 1.5VDC saturation, 100mA maximum load.
Analog Inputs (2) 0 to +/- 10 VDC, differential input impedance - differential > 1m ohm; 20K ohms (single ended to analog common).
Analog Outputs (2) -10 to +10VDC, 2.5mA maximum output impedance - 200 ohms.
Power Supply (for external use) +10VDC, 4mA maximum, -10VDC, 4mA maximum.
Node Adapter board This board allows the Bulletin 1395 to be controlled using an Allen-Bradley PLC controller from either the PLC3 or PLC5 family. The +5V Node Adapter board power is generated internally in the Drive.
Multi-Communications Adapter Board
Power Supply Board power provided by Drive discrete input, 24VDC or 115VAC, jumper selectable.
Communications Channels (2) Each channel can be configured as either Allen-Bradley Remote I/O (RIO) or Allen-Bradley Data Highway + (DH+) interfaces.
Compatible with PLC3, PLC250,PLC5/15, PLC5/25, PLC5/40, PLC5/60 and Controlview.
Function Blocks (4) These programmable function blocks can be used to manipulate data.
Discrete Input (1) One programmable discrete input is available
(24VDC or 115VAC).