Subject Specifications
AC Input Frequency Tolerance 50/60Hz ±3Hz
AC Input Voltage Tolerance ±10%
Overload Capability 1 minute out of 20 minutes at rated load and temperature
Minimum Continuous Load Requirement 33% of rated DC bus continuous current
Operating Altitude Up to 1000 meters (3,300 feet) †
Ambient Temperature (Operating) 0 to 40°C (32 to 104°F)
Relative Humidity (Operating/Storage) 5 to 95%, non-condensing
Ambient Temperature (Storage) -40 to 70°C (-40 to 158°F)
† For altitudes greater than 1000 meters, refer to the altitude derate chart.



Unit Specifications
The following specifications apply to the 1250, 1650, and 3000A DC drives with standard options.

Specifications

1250A Drive

1650A Drive

3000A Drive

Height1
91.5”
(2324 mm)
91.5”
(2324 mm)
111.5”
(2832 mm)2
Width
75” (1905 mm)
75” (1905 mm)
95” (2413 mm)
Depth
20” (508 mm)
20” (508 mm)
20” (508 mm)
MCC Sections
3
3
4
Shipping Weight
2500 lbs (1134 kg)
2500 lbs (1134 kg)
3500 lbs (1588 kg)
Operating Sound Level
dB, wt. A
83 dB, wt. A
82 dB, wt. A
1The height includes a 1.5"-high base channel.
2The height for the 3000A unit includes the enclosure height (90"), the base channel (1.5"), and the tophat assembly (20"). The top hat assembly is shipped loose from the unit.

Electrical Specifications (1250A DC Drive)
Input
Output
Nominal Input Voltage (V AC)
Nominal Input Power (kVA)
Nominal Armature Voltage
(V DC)
Nominal Armature Current
(A DC)
Maximum Field Voltage
(V DC)
Maximum Field Current (A DC)
Nominal HP
460
750
500
1100
300
43 or 90
700
460
848
500
1250
300
43 or 90
750
575
856
600
1000
300
43 or 90
750
575
909
600
1065
300
43 or 90
800
575
1060
600
1250
300
43 or 90
900
660
852
700
860
300
43 or 90
750
660
904
700
915
300
43 or 90
800
660
1011
700
1030
300
43 or 90
900
660
1217
700
1250
300
43 or 90
1000

Electrical Specifications (1650A DC Drive)
Input
Output
Nominal Input Voltage (V AC)
Nominal Input Power (kVA)
Nominal Armature Voltage
(V DC)
Nominal Armature Current
(A DC)
Maximum Field Voltage
(V DC)
Maximum Field Current (A DC)
Nominal HP
460
867
500
1280
300
43 or 90
800
460
972
500
1440
300
43 or 90
900
460
1108
500
1650
300
43 or 90
1000
575
1125
600
1330
300
43 or 90
1000
575
1385
600
1650
300
43 or 90
1250
660
1590
700
1650
300
43 or 90
1250

Electrical Specifications (3000A DC Drive)

Input
Output
Nominal Input Voltage (V AC)
Nominal Input Power (kVA)
Nominal Armature Voltage
(V DC)
Nominal Armature Current
(A DC)
Maximum Field Voltage
(V DC)
Maximum Field Current (A DC)
Nominal HP
460
1374
500
2000
300
43 or 90
1250
460
1634
500
2400
300
43 or 90
1500
460
2024
500
3000
300
43 or 90
1750
575
1713
600
1995
300
43 or 90
1500
575
1985
600
2330
300
43 or 90
1750
575
2254
600
2660
300
43 or 90
2000
575
2531
600
3000
300
43 or 90
2250
660
1705
700
1715
300
43 or 90
1500
660
1971
700
2000
300
43 or 90
1750
660
2242
700
2290
300
43 or 90
2000
660
2508
700
2575
300
43 or 90
2250
660
2905
700
3000
300
43 or 90
2500

 

The 1250, 1650, and 3000A DC drives dissipate power proportionally to the armature current, as shown in the following figures.