Drives Service & Support
Click for Specifications
| Physical Dimensions |
| Current Code |
Height |
Overall Width |
Overall Depth |
Number of MCC Sections |
| J |
90"
(2286 mm) |
25"
(635 mm) |
15 or 20" (508 mm) |
1 |
| K |
90"
(2286 mm) |
45"
(1143 mm) |
20"
(508 mm) |
2 |
| L |
91.5"
(2324 mm) |
45"
(1143 mm) |
20"
(508 mm) |
2 |
| M |
103.5"
(2629 mm) |
45"
(1143 mm) |
25"
(635 mm) |
2 |
| N |
91.5"
(2324 mm) |
45"
(1143 mm) |
25"
(635 mm) |
3 |
| 1The L, M, and N-code RGU heights include a 1.5 inch-high base channel (standard). This base channel is an option for the J and K-code RGUs. |
| 2The M and N-code RGUs use both 20-inch deep MCC(s) and a 25-inch deep MCC, having an overall depth of 25 inches. Figure 1 shows top-view illustrations of the M and N-code RGUs. |
| The M-code height (103.5") includes the enclosure height (90"), the base channel (1.5"), and a top hat assembly (12"). The top hat assembly is shipped loose from the unit. |
| Physical Dimensions |
| Unit Current Code |
Weight of Regenerative Module1 |
Weight of Complete RGU Unit |
| J |
85 lb (39 kg) |
970 lb (440 kg) |
| K |
260 lb (119 kg) |
1450 l b (658 kg) |
| L |
440 lb (200 kg) |
2020 l b (916 kg) |
| M |
1000 lb (455 kg) |
2900 lb (1316 kg) |
| N |
1000 lb (455 kg) |
3850 lb (1746 kg) |
| 1The regenerative module for the J current code RGU is panel mounted. The regenerative modules for the K, L, M, and N current code RGUs are built as roll-out module assemblies. |
|