Drives Service & Support Legacy
Operating Specifications
The drive controller and motor are designed to operate under the following conditions and with the following performance characteristics:
- Voltage: 230V + 10%, -5%; single phase; 60 Hz
- Maximum Operating Ambient Temperature: 40°C (104 F).
- Speed Deviation (Regulation): Under conditions of constant line voltage and constant temperature, the total speed deviation of the motor with a load change from 10% of full load to 100% will not exceed 1% of the rated motor base speed with tachometer feedback and 2% with armature feedback. This speed regulation will be obtained at any speed between base speed and 1/30 of base speed.
For example, a motor having a base speed of 1750 RPM will not experience a speed deviation of more than 17.5 RPM under this load change with tachometer feedback and 35 RPM with armature feedback . The speed deviation is affected by ambient temperature and line voltage changes. A change in ambient temperature from 25°C to 40°C could produce a speed change as great as 6% if the line voltage is held constant. Similarly, a variation in line voltage of 10% could produce a speed change of 6% if the temperature is held constant.
- Maximum Permissible Continuous Torque: The actual load that can be drawn from the motor or the duty cycle which it can sustain depends on the motor frame and enclosure. If a motor is to be operated at greatly reduced speed for long periods of time, it may be necessary to derate the motor in accordance with the table below.
Percent Base Speed |
Percent Rated Torque |
Drip-Proof |
TENV |
| 50 |
100 |
100 |
| 40 |
92 |
100 |
| 25 |
80 |
100 |
| 6 |
65 |
100 |
|