;(1352c5.def) ;ABOVE LINE USED FOR DMS DEFINITION FILE IDENTIFICATION ;THIS INDICATES SCALAR FIRMWARE VER. 4.04A or newer ; ;software overlay file 508073.002 for use with national machine software ;option S70 software: S70 is the NATL MACHINE program -- this overlay ;DOES NOT have an S number -- it is MAC number software for internal use ;only. THIS OVERLAY IS USED TO RECONFIGURE THE NATL MACHINE DRIVES FOR USE ;WITH 460VAC APPLICATIONS. THE DEFAULT VALUES OF 508070-18 ARE SETUP FOR ;380VAC/50HZ APPLICATIONS. THIS SOFTWARE IS ONLY FOR USE WITH 508070-18. ; MLE 19 aug 92 ; ; 8 1 unlock eeprom ; 1332 6000 ANA_IN_0:MAX 1333 -1500 ANA_IN_0:MIN ; 1308 6000 ANA_IN_1:MAX 1309 -1500 ANA_IN_1:MIN ; 1683 6000 DISPLAY0:MAX ; 1567 460 DISPLAY4:MUL4 ; 62 6000 SCALAR:FREQMAX 63 -6000 SCALAR:FREQMIN 65 460 SCALAR:RATED_AC_VOLTAGE 68 6000 SCALAR:FLDWKPNT ; 1672 6000 LIM0 (block#51):MAX ;