| AC Line Voltage |
Single phase 120 or 240V AC, (+ 10%, -5%) |
| AC Line Frequency |
50 or 60 ±2 Hz |
| AC Control Voltage |
120V AC (Not for external use) |
| Armature Power Supply |
Single Phase Fill Wave Non-Regenerative |
| Armature Current Limit Range |
0 to 100% rated current for continuous operation; to 150% current for 1 minute |
| Shunt Field Supply Rating |
100V or 200V DC at 1½ amperes (max.) with field economizing to reduce standby power to 25% |
| Drive HP Range |
- ¼ to ¾ HP at 120V AC
- 1 to 5 HP at 240 V AC
|
| Regulation Types |
- Armature Voltage
- Speed
- Torque/Current
|
| SPEED REGULATION (% OF BASE SPEED) |
| Feedback Source |
Operating Deviation |
Service Deviation |
| Armature Voltage |
2% |
5% |
| AC Tachometer |
1% |
2% |
| DC Tachometer |
1% |
1% |
| |
| Current Limit |
NEMA Type 1 - 31 Ibs (14.04 kg) Adjustable Oto 150% of rated Controller CUrrent |
| IR Compensation |
Adjustable from O to 10% of maximum armature terminal voltage |
| Adjustable Maximum Speed |
50 to 120°/0 of motor base speed |
| Adjustable Minimum Speed |
0 to 50°A of Maximum Speed Pot Setting |
| Adjustable Jog Speed (Optional) |
0 to 50% of Maximum Speed pot setting |
| Adjustable Preset Speed (Optional) |
0 to 100% of Maximum Speed pot setting |
| Linear Accel/Decel Rates |
100V or 200V DC at 1M amperes (max.) with field Separately adjustable 0.2 to 50 sec. |
| Adjustable Torquetaper |
50 to 150% of rated current |
| DC Motor Powersupply Code |
NEMA Design "K' |
| Ambient Temperature Range |
0°C (32°F) to 4(YC (104°F) - Operating
Torque/Current 0 °C (32°F) to 65°C (149°F) - Storage |
| Relative Humidity |
5 to 95%. (non-condensing) |
| Operational Altitude |
3300 ft (1000 m) |
| Approximate Shipping Weight |
- CURRENT LIMIT Open Type - 20 Ibs (9.06 kg)
- NEMA Type 1 - 31 Ibs (14.04 kg)
- NEMA Type 12 - 112 Ibs (50.74 kg
|