The SpeedPak Custom Field Reversing Regenerative Drives

Status Inactive: August, 1993
Discontinued: August, 1998
Obsolete: August, 2000
Recommended Upgrade Bulletin 1395

Specifications

  • Three Phase - Six Pulse
  • Power Units - 2 thru 1500 HP

The specifications as listed below apply to the basic SPEEDPAK control. These specifications may vary for a given system design due to the particular D.C. motor characteristics.

Environment - The basic power unit is designed to operate under the following conditions.

  • Altitude: Up to 3300 feet above sea level
  • Ambient Temperature: 40°C (104°F) maximum
  • Line Voltage Variation: -5% to +10%
  • Line Frequency: 50 or 60 Hz.

Speed Range - 1000:1
Note: Motor Heating and Torque - Motor design in many instances limits the amount of torque that can be produced at reduced motor speeds. This is usually dependent on type of enclosure, class of insulation, and frame size. If continuous full load torque is required at low speeds, some supplementary ventilation or a derated motor must be supplied.

All standard motor base speeds are available.

Speed Regulation - No load to full load: 0.1% by tachometer feedback

Power Conversion Efficiency - 98%


Standard Modifications Available

  • Contactor-less Reversing
  • Linear Acceleration
  • Jog Speed - Separately Adjustable
  • Thread Speed - Separately Adjustable
  • Auto/Manual Relay
  • Tachometer Loss "Runaway" Protection

EQUIPMENT LIST

DRIVE CONTROL ASSEMBLY

Enclosure

NEMA 1 gasketed with filtered ventilation openings

Basic A.C. Control

  • Incoming A.C. power terminals
  • 115 volt fused control and transformer
  • Auxiliary fusing
  • Field power transformer (optional)
  • Run relay - Regulator relay

Basic D.C. Control

  • HP rated D.C. loop contactor
  • Overload protection

Regulator

  • Precision regulated reference (20 volts)
  • D.C. tachometer feedback
  • Maximum speed adjustment - High gain OP amps
  • Continuous current limit, adjustable 0-150%
  • Phase loss and current unbalance protection
  • Front wiring and patented screw type terminals on printed circuit boards. Boards removable without removing wiring.
  • 12 channel circuit analyser with meter and selector switch
  • No interaction between drive adjustments

Armature Power Unit

  • 6 SCR full wave bridge
  • Pulse distribution matrix and amplifier
  • Transient voltage filters
  • Integral air fan and flow switch (above 10 HP)
  • Protective metal enclosure

Field Power Units

  • Push-Pull reversing SCR controlled field supply
  • Transient voltage filters
  • Inherent field loss prectection and field economizing

Isolation Transformer - Standard

  • Three phase 480 volt primary
  • Secondary voltage as required for specified armature voltage
  • NEMA 1 enclosed for separate mounting

Industrial - Type Drive Motor

  • Designed for use with static power supply - available with a wide variety of optional features