Drives Service & Support Click for Dimensions
| Specific Drive Ratings |
| |
1391-DES15 |
1391-DES22 |
1391-DES45 |
| Nominal Bus Voltage |
300V DC |
300V DC |
300V DC |
| Continuous Current (RMS) |
15A |
22.5A |
45A |
| Peak Current (RMS) |
30A |
45A |
90A |
| Continuous Power Output |
5.0 kW |
7.5 kW |
15.0 kW |
| Peak Power Output |
10.0 kW |
15.0 kW |
30.0 kW |
| Input Circuit Breaker Rating |
17A RMS |
26A RMS |
38A RMS |
| Circuit Breaker Interrupt Rating (Symmetrical Amperes) |
1300A |
1300A |
1300A |
| Unit Weight in lbs (kg) |
22 (9.97) |
28 (12.69) |
34 (15.40) |
| All Drive Ratings |
| Static Gain (A/RMS) |
1.5 x Rated Motor Current / rpm (typical) |
| Form Factor |
1.03 or less |
| Peak Current Limit Adjust |
20 to 300% of Rated Motor Current or 2 x Continuous Rating of Drive (max.), whichever achieves Drive Peak Current Rating first |
| Drive Efficiency |
85% (Minimum at Rated Load) |
| Power Factor |
95% Minimum |
| Modulation Frequency |
2500 Hz ±10% |
| Drift (Referred to Tach) |
0.07 rpm /Degrees C. Maximum |
| Speed Regulation |
0 to 0.05% of Maximum Motor Speed with 95% Load Change |
| Ambient Temperature |
0 to 60° C (32 to 140° F) |
| Storage Temperature |
0 to 65° C (32 to 149° F) |
| Input Voltage (from Transformer) |
Power: 230V AC +10%/-15%, Three-Phase, 50/60 Hz ±3 Hz
Control: 36V AC, Single-Phase |
| Transformer Input Tolerance |
+10%, -15% |
| Relative Humidity |
5 to 95% Non-Condensing |
| Deadband |
Zero |
| Altitude |
1000 meters (3300 feet) |
| Integral Fan Output |
50 CFM (Unloaded) |
| Max. RMS Short Circuit Current |
1300A (Symmetrical Amperes) |
| Certifications |
UL Listed - File No. E59272, CSA Certified - File No. LR32334-548, |
| Specifications are for reference only and are subject to change without notice. |
Environmental Specifications
The 1391-DES must be mounted in an enclosure that is clean, dry and ventilated by filtered or cooled air. Enclosures vented with ambient air must have appropriate filtering to protect against contamination caused by oils, coolants, dust, condensation etc. The ambient air temperature must be kept between 0 to 60° C (32 to 140° F) and the humidity between 5 and 95%, non-condensing.
The 1391-DES is equipped with an integral cooling fan. The general flow of air through the unit must be maintained by following the recommended spacing guidelines found in Chapter 7. The 1391-DES can operate at elevations to 3300 feet (1000 meters) without derating, however, the current rating must be derated by 3% for each additional 1000 feet (305 meters) up to 10,000 feet (3050 meters). Consult with your local Allen-Bradley Sales Representative prior to operation over 10,000 feet (3050 meters).
Specific Drive Ratings |
| Rated Power Output (%) |
1391-DES15 (watts) |
1391-DES22 (watts) |
1391-DES45 (watts) |
| 20 |
38 |
55 |
104 |
| 40 |
76 |
110 |
208 |
| 60 |
114 |
165 |
312 |
| 80 |
152 |
220 |
416 |
| 100 |
190 |
275 |
520 |
| Transformer Power Dissipation |
| Rated Power Output (%) |
1.5kVA
(watts) |
3.5kVA
(watts) |
5.0kVA
(watts) |
10.0kVA
(watts) |
12.5kVA
(watts) |
15.0kVA
(watts) |
| 20 |
13 |
35 |
50 |
100 |
125 |
150 |
| 40 |
25 |
70 |
100 |
200 |
250 |
300 |
| 60 |
38 |
105 |
150 |
300 |
375 |
450 |
| 80 |
50 |
140 |
200 |
400 |
500 |
600 |
| 100 |
60 |
175 |
250 |
500 |
625 |
750 |
| Important: Power Dissipation figures shown are for use in calculating cumulative system heat dissipation to ensure ambient temperature inside enclosure does not exceed 60° C (140° F). |
|