The “3R” and “3RA” designations for the 1321 line reactors indicate
the following: 3R = Open Enclosure Line Reactor and 3RA = NEMA
1 Enclosure Line Reactor.
| Material |
| Enclosures |
- IP10 (NEMA Type 1) Sheet steel in accordance with UL, NEMA and CSA requirements.
- IP00 (Open)
|
| Terminations |
- 1-45 Amp (fundamental) Ratings – Finger guard IP20 terminal block
- 80-200 Amp (fundamental) Ratings – Solid copper box lugs
- 250-400 Amp (fundamental) Ratings – Copper tab terminals
- 401 Amps and Above – Copper tab terminals
|
| Harmonic Compensation |
| |
All line reactors are compensated for the additional currents and
high frequencies caused by the presence of harmonics. |
| General Protection |
| Impedance |
3% or 5% based on the fundamental current ratings. |
| Overload Rating |
300% of fundamental current for (1) minute. |
| IGBT Protection |
| |
First turn triple insulated offering protection up to 16kV.
- 16,000 Volts per Microsecond dv/dt Protection
- 20 kHz Maximum Switching Frequency
|
| Electrical |
| Max. Rated Voltage |
600VAC, 50/60Hz frequency. |
| Max. Switching Freq. |
20kHz. |
| Temperature Rise |
115 degrees C. |
| Dielectric Strength |
4,000 volts rms (5,600 volts peak). |
| Inductance Curve |
- 100% at 100% current.
- 100% at 150% current.
- 50% at 350% current.
|
| Insulation System |
Class H (180 degrees C or better). |
| Impregnation |
High bond strength epoxy impregnation.
4,000V high dielectric strength. |
| Environmental |
| Ambient Temperature |
40 degrees C. |
| U.L. Recognized |
UL-506 IP00 (Open). |
| U.L. Listed |
UL-508 IP20 (NEMA Type 1). |
| International |
Conforms to IEC-289 and VDE 0550. |
| CSA Certified |
CSA C22.2 |
| CE |
EN 60076 |