| Category |
Specifications |
| Environment |
Altitude |
1000 m (3300 ft) max. without derating |
Ambient Operating Temperature |
IP20: 10 to 50 degrees C (14 to 122 degrees F)
NEMA 1: 10 to 40 degrees C (14 to 104 degrees F) |
Cooling Method
|
Convection: 0.2 kW (0.25 HP) drive ratings, Catalog Numbers 22A-V1P5N104, 22A-A1P5N114, 22A-A1P5104 and 22A-B1P5N104
Fan: All other drive ratings. |
| Storage Temperature: |
40 to 85 degrees C (40 to 185 degrees F) |
| Atmosphere: |
Important: Drive must not be installed in an area where the ambient atmosphere contains volatile or corrosive gas, vapors or dust. If the drive is not going to be installed for a period of time, it must be stored in an area where it will not be exposed to a corrosive atmosphere. |
| Relative Humidity: |
0 to 95% non-condensing |
| Shock (operating): |
15G peak for 11ms duration (±1.0ms) |
| Vibration (operating): |
1G peak, 5 to 2000 Hz |
| Control |
Carrier Frequency |
2-16 kHz. Drive rating based on 4 kHz. |
| Frequency Accuracy |
Digital Input: Within ±0.05% of set output frequency.
Analog Input: Within 0.5% of maximum output frequency. |
Speed Regulation - Open Loop
with Slip Compensation: |
±2% of base speed across a 40:1 speed range. |
| Stop Modes: |
Multiple programmable stop modes including - Ramp, Coast, DC-Brake, Ramp-to-Hold and S Curve. |
| Accel/Decel: |
Two independently programmable accel and decel times. Each time may be programmed from 0 - 600 seconds in 0.1 second increments. |
| Intermittent Overload: |
150% Overload capability for up to 1 minute
200% Overload capability for up to 3 seconds |
Electronic Motor Overload
Protection |
Class 10 protection with speed sensitive
response. |