Selecting 3 Different Speed Command Sources: 0 to Volts, Preset 1 = 10 Hertz, Preset 2 = 30 Hertz

Parameters that need to be reprogrammed
File - Inputs & Outputs
Group - Digital Inputs

361 (Digital In1 Sel) = N/A
362 (Digital In2 Sel) = N/A
363 (Digital In3 Sel) = N/A
364 (Digital In4 Sel) = 15
365 (Digital In5 Sel) = 16
366 (Digital In6 Sel) = N/A

File - Speed Command
Group - Speed References

90 (Speed Ref A Sel) = 2 (Analog In 2)
93 (Speed Ref B Sel) = 11 (Preset Spd1)

File - Speed Command
Group - Discrete Speeds

101 (Preset Speed 1) = 10 Hz
102 (Preset Speed 2) = 30 Hz

Speed Sel 1 = Open = Speed Source is 0 to 10 Volts
Speed Sel 2 = Open
Speed Sel 1 = Closed = Speed Source is Preset 1
Speed Sel 2 = Open
Speed Sel 1 = Open = Speed Source is Preset 2
Speed Sel 2 = Closed