Reliance Electric™ Drives Service & Support
FlexPak 3000 Drives
Specifications
Controller Ratings
HP
Ratings |
Full Load Rated RMS AC Line Current (Amps) |
Full Load Rated RMS DC Armature Current (Amps) |
Rated Field Current (Amps) |
230
VAC |
460
VAC |
240
VAC |
500
VAC |
150
VDC |
300
VDC |
| 1.5 |
10 |
- |
7 |
- |
10 |
- |
| 2 |
11 |
- |
9 |
- |
10 |
- |
| 3 |
13 |
10 |
12 |
6 |
10 |
10 |
| 5 |
19 |
12 |
20 |
10 |
10 |
10 |
| 7.5 |
26 |
15 |
29 |
14 |
10 |
10 |
| 10 |
33 |
18 |
38 |
19 |
10 |
10 |
| 15 |
48 |
24 |
55 |
27 |
10 |
10 |
| 20 |
63 |
31 |
73 |
35 |
15 |
10 |
| 25 |
80 |
39 |
93 |
45 |
15 |
10 |
| 30 |
94 |
45 |
110 |
52 |
15 |
10 |
| 40 |
125 |
63 |
146 |
73 |
15 |
15 |
| 50 |
154 |
74 |
180 |
86 |
15 |
15 |
| 60 |
186 |
86 |
218 |
100 |
15 |
15 |
| 75 |
226 |
110 |
265 |
129 |
15 |
15 |
| 100 |
307 |
143 |
360 |
167 |
15 |
15 |
| 125 |
370 |
177 |
434 |
207 |
15 |
15 |
| 150 |
443 |
213 |
521 |
250 |
15 |
15 |
| 200 |
- |
281 |
- |
330 |
- |
15 |
| 250 |
- |
351 |
- |
412 |
- |
15 |
| 300 |
- |
421 |
- |
495 |
- |
15 |
| 400 |
- |
567 |
- |
667 |
- |
15 |
| 500 |
- |
680 |
- |
800 |
- |
15 |
| 600 |
- |
816 |
- |
960 |
- |
15 |
Service Conditions
- Standard altitude: to 3300 feet
(1000 meters)
- Standard ambient temperature
- Cabinet units: 0-40C
(32F to 104F)
- Chassis units: 0-55C
(32F to 131F)
- AC line voltage variation: +/- 10%
- AC line frequency: 48/62 Hz
- AC line distribution system KVA capacity
(1)
- Maximum 3 drives per
transformer (1)
- FlexPak 3000 drives are 50/60 Hz
- Atmosphere: non-condensing
relative humidity 5 to 95%
Efficiency and Power Factor
- Displacement power factor
at maximum speed: 88%
- Efficiency of power module at:
- 100% speed and 100% load:
99.3%
- 100% speed and 25% load: 98.5%
- 25% speed and 100% load: 96.8%
- 25% speed and 25% load: 94.0%
- Efficiency of drive including motor
is typically 87%
Capacities
- Service factor: 1.0
- Maximum load: 150% for one
minute, 200% for 5 seconds
Speed Range
- Operator’s speed adjustment: 0 to
rated speed
- Specification speed range: 100:1
based on top speed and tachometer
(1) When applying FlexPak 3000 drives to power
distribution systems with KVA capacity in
excess of five times the smallest drive rating use
of an isolation transformer or line reactors of
similar impedance is required.
(2) Dependent of top speed and pulse tachometer
used.
5PY = 30:1
RD120 = 70:1
RL1024 =100:1
Speed Regulation
| Regulation Arrangement |
Speed Change with
95% Load Change |
Speed Change from
All Other Variables |
Kit Model
Number |
| Armature Voltage w/ IR Compensation |
2-3% |
15% |
Not applicable |
| Closed Loop |
| w/ 5PY tach (3) |
1% |
2% |
|
| w/ RD-120-1 tach (4) |
0.01% |
0.01% |
907FK0101 |
| w/ RD-120-2 tach (4) |
0.01% |
0.01% |
907FK0101 |
| w/ RL1024 encoder (4) |
0.01% |
0.01% |
907FK0101 |
(3)
Standard DC Tachometer
(4)
Optional Pulse Encoder Feedback kit required |