Specifications

Input Voltage and Frequency Ratings
Nominal Line Voltage 115 or 230 VAC
Number of Phases Single
Voltage Variation +/- 10% of nominal
Nominal Line Frequency 50 or 60 cycles
Frequency Variation +/- 2 cycles of nominal
AC Line Fault Ampacity
Allowable AC Line Symmetrical Fault Current (RMS) 5000 Amp (With NEC or CEC approved external disconnect)
AC Line KVA
Maximum Source KVA See Table on front page
Multiple Drives Per Line Maximum 3 Drives Per Line
Minimum Source KVA See Table on front page
DC Voltage Ratings
115VAC Line Armature Voltage 90 VDC
115VAC Line Field Voltage 50 or 100 VDC
230VAC Line Armature Voltage 180 VDC
230VAC Line Field Voltage 100 or 200 VDC
Service Factor Ratings
Service Factor 1.0 Continuous
Overload Capacity (Controlller Only) 1.5 of full load rating for one minute
Minimum Load 5% of rated load
Service Conditions
Thermal Chassis 55°C Maximum
Thermal Cabinet 40°C Maximum
Altitude
Chassis and Cabinet 3300 feet above sea level
Above 3300 Feet Derate 3% for every 1000 ft.
Humidity
Chassis and Cabinet 5 to 95% Non-condensing
Environment
The controller shold be located in an area that is free of dust, dirt, acidic, or caustic vapors, vibration and shock, temperature extremes, and electrical or electromagnetic noise interference.

 

Basic Regulator Maximum Recommended Operating Adjustments:

Caution: The following adjustments are maximum safe operating ranges. Potentiometers on the regulator, particularly current limit, may exceed these ranges. Failure to observe this precaution could result in damage to, or destruction of, equipment.

Maximum Speed 50 to 100% of motor base speed
Minimum Speed 0 to 50% of motor base speed
Current Limit 10 to 150% of rated load
IR Drop Compensation 0 to 12% of armature voltage at rated load
Acceleration Rate 0.5 to 30 seconds
Decelration Rate 0.5 to 30 seconds
Regulation (with 95% load change)
Armature Voltage Regulation 2 to 3% of base speed with IR Drop Compensation
Speed Regulation RE045 or 5PY Tach - 1.0% of base speed
  BC42 tach - 0.5% of base speed
Speed Range
Operator's Speed Adjustment 0 to 100%
Specification Speed Range 20 : 1
Drive Efficiency
Controller Only 97% (rated load and speed)
Controller and Motor 85% typical (depends on motor base speed and frame size)
Displacement Power Factor
Displacement PF 68% typical (depends on motor base speed and frame size)

 

 

 

 

 

 


Support Options
Discussion Forum
Paid Support Options
Obsolete Support Options

Electronic Data Sheets (EDS)

Nameplate Locator
Product Advisories
Firmware & Software Updates Web Updates
   
Get Literature
Knowledgebase
Drive Drawings
Technical Documents
NEMA Documents
Electronics Maintenance
   
Contact Us
Email a Technical Question
Who do I Call?
Meet the Support Team
   
Extra
Rockwell Modem Support
Environmental Commitment