| Environment |
| Elevation |
- 1,000 meters without derating
- Derate 1% for every 90 meters
above 1000 meters
|
| Ambient operating temperature without derating |
Open Type, IP 20: -10° C (14° F) to 50° C (122° F)
NEMA 1, IP30, UL Type 1: -10° C (14° F) to 40° C (104° F) |
| Storage temperature (all constructions) |
-40° C (-40° F) to 85° C (185° F) |
| Cooling Method |
1 HP and above: Fan
0.5 HP drives: Convection |
| Atmostphere |
The drive must not be installed in an area where the ambient atmosphere contains volatile or corrosive gas, vapors, or dust. If the drive is not going to be installed for a period of time, it must be stored in an area where it will not be exposed to a corrosive atmosphere. |
| Relative Humidity |
0% to 95%, non-condensing |
| Shock (operating) |
15 G peak for 11 ms duration (+/-1.0 ms) |
| Vibration (operating) |
1 G peak, 5 to 2000 Hz |
| |
| Input/Output Rating |
| Output Frequency |
0-400 hz (programmable) |
| Efficiency |
97.5% (typical) |
| |
| Control |
| Carrier Frequency |
2-16 kHz. Drive rating based upon 4 kHz |
| Frequency Accuracy Digital Input |
Within + 0.05% of set output frequency |
| Frequency Accuracy Analog Input |
Within 0.5% of maximum output frequency. 10-bit resolution |
| Frequency Accuracy Analog Output |
+/-2% of full scale. 10-bit resolution |
| Speed Regulation - Open Loop with Slip Compensation |
+/-1% of base speed across a 60:1 speed range |
| Stop Modes |
Multiple programmable stop modes including: Ramp, Coast, DC-Brake, Ramp-to-Hold, S Curve, and Dynamic Braking (1 HP and above).. |
| Accel/Decel |
Two independently programmable accel and decel times. Each may be programmed from 0-600 seconds (0.1 second
increments) |
| Intermittent Overload |
150% Overload capability for up to 1 minute
200% Overload capability for up to 3 seconds |
| Electronic Motor Overload Protection |
Class 10 protection with speed-sensitive response |
| |
| Digital Control Inputs |
| SRC (source) Mode |
18-24 V = ON; 0-6 V = OFF |
| SNK (Sink) Mode |
0-6 V = ON; 18-24 V = OFF |
| |
| Analog Control Inputs |
| 4-20 mA Analog |
250 ohm input impedance |
| 0-10 V DC Analog |
100k ohm input impedance |
| External Pot |
1-10 k ohms, 2 Watt minimum |
| |
| Fuses & Circuit Breakers |
| Recommended Fuse Type |
UL Class J, CC, T or Type BS88; 600 V (550 V) or equivalent |
| Recommended Circuit Breakers |
HMCP circuit breakers or equivalent. |
| |
| Control Output |
| Programmable Output (form C relay) |
| Resistive Rating |
3.0 A at 30 V DC, 3.0 A at 125 V AC, 3.0 A at 240 V AC |
| Inductive Rating |
0.5 A at 30 V DC, 0.5 A at 125 V AC, 0.5 A |
| Opto Outputs |
| Resistive Rating |
30 V DC, 50 mA |
| Inductive Rating |
Recover Diode |
| Analog Outputs (10-bit) |
| Rating |
4-20 mA, 525 ohm max
0-10 V, 1k ohm min. |
| |
| Protective Features |
| Motor Protection |
Programmable I2t overload protection provides Class 10 protection. See parameter P033 |
| Overcurrent |
200% hardware limit, 300% instantaneous fault |
| Bus Overvoltage Trip |
100-120 & 200-240 VAC: 405 VDC (150 & 290 VAC equiv) |
| 380-460 VAC: 810 VDC (575 VAC equiv) |
| 460-600 VAC: 1005 VDC (701 VAC equiv) |
| Bus Undervoltage Trip |
100-120 & 200-240 VAC: 210 VDC (75 & 150 VAC equiv) |
| 380-480 VAC: 390 VDC (275 VAC equiv) |
460-600 VAC: if P042 = 3 : 487 VDC (344 VAC equiv)
460-600 VAC: if P042 = 2 : 390 VDC (275 VAC equiv) |
| Control Ride-Through |
Minimum 0.5 seconds - typical 2 seconds |
| Fault-Free Ride-Through |
100 milliseconds |
| |